• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dimensionamento de um sistema fotovoltaico conectado à rede a partir das características de inclinação e orientação dos módulos fotovoltaicos / Design of a grid-connected photovoltaic system from the photovoltaic modules tilt and azimuth angles characteristics

Paiva, Gabriel Mendonça de 03 June 2016 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2016-10-18T20:19:54Z No. of bitstreams: 2 Dissertação - Gabriel Mendonça de Paiva - 2016.pdf: 3565340 bytes, checksum: 6df5384c34ed001061350c147d523756 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2016-10-19T16:18:31Z (GMT) No. of bitstreams: 2 Dissertação - Gabriel Mendonça de Paiva - 2016.pdf: 3565340 bytes, checksum: 6df5384c34ed001061350c147d523756 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-10-19T16:18:31Z (GMT). No. of bitstreams: 2 Dissertação - Gabriel Mendonça de Paiva - 2016.pdf: 3565340 bytes, checksum: 6df5384c34ed001061350c147d523756 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-06-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This study aimed to evaluate the design of a grid-connected photovoltaic (PV) system according to the positioning of the modules which compose the generator depending on tilt and azimuth angles in Goiânia, Goiás. In that purpose, a review of the literature was carried out concerning the main methods of inverter sizing ratio analysis applied to grid-connected PV systems. Starting from an hourly average climate measurement database from Goiania, an algorithm was developed to search for the ideal local inverter sizing ratio, considering the use of polycrystalline module technology. The parameters used in the analysis were provided by the manufacturers of the componentes used in the grid-connected PV system in installation at the Electrical, Mechanical and Computational Engineering School (EMC) from Federal University of Goias (UFG), which nominal power is 33.84 kWp. An inverter sizing ratio band of 0.54 to 0.77 was obtained for a -90° to +90° azimuth angle variation and 0° to 90° tilt angle variation. The potential of financial indicators improvement was verified and it was estimated a potential reduction in the levelized cost of energy above 10% comparing the inverter sizing ratio improved system to an unitary inverter sizing ratio system. / Este estudo tem como objetivo avaliar o dimensionamento de um sistema fotovoltaico conectado à rede (SFCR) de acordo com o posicionamento dos módulos que compõem o gerador quanto ao ângulo de inclinação e ao ângulo azimutal em Goiânia, Goiás. Para isso foi realizada uma revisão da literatura quanto às principais metodologias de análise do fator de dimensionamento do inversor (FDI) aplicado a SFCRs. A partir de uma base de dados em intervalos horários de medições climáticas de Goiânia desenvolveu-se um algoritmo para busca do FDI ideal para a localidade, considerando o uso de módulos de silício policristalino (p-Si). Os parâmetros utilizados na análise foram os parâmetros fornecidos pelos fabricantes dos componentes utilizados no SFCR em instalação da Escola de Engenharia Elétrica, Mecânica e de Computação (EMC) da Universidade Federal de Goiás (UFG), cuja potência nominal é de 33,84 kWp. Os métodos de análise do FDI foram comparados e foi considerado mais adequado neste estudo o método das perdas máximas anuais por limitação de potência no inversor. A faixa de FDI obtida para uma variação de -90° a +90° no ângulo azimutal e de 0° a 90° no ângulo de inclinação foi da ordem de 0,54 a 0,77. O potencial de aprimoramento de indicadores financeiros por meio do FDI foi verificado e foi estimada uma potencial redução acima de 10% do custo da energia produzida comparando o aperfeiçoamento do FDI com um FDI unitário.

Page generated in 0.1669 seconds