Spelling suggestions: "subject:"fault courrent limiter"" "subject:"fault courrent imiter""
11 |
Recovery characteristics after current limitation of high temperature superconducting fault current limiting transformer (HTc-SFCLT)Kurupakorn, C., Kojima, H., Hayakawa, N., Goto, M., Kashima, N., Nagaya, S., Noe, M., Juengst, K.-P., Okubo, H. 06 1900 (has links)
No description available.
|
12 |
High-Tc Superconducting Fault Current Limiting Transformer ( HTc-SFCLT ) With 2G Coated ConductorsOkubo, H., Kurupakorn, C., Ito, S., Kojima, H., Hayakawa, N., Endo, F., Noe, M. January 2007 (has links)
No description available.
|
13 |
High Temperature Superconducting Partial Core Transformer and Fault Current LimiterSham,Jit Kumar January 2015 (has links)
The thesis begins with an introduction to transformer theory. The partial core transformer is then introduced and compared with a full core design. A brief introduction to superconductors and high temperature superconductors is then presented. High temperature superconducting fault current limiters are then examined and the advantage of a high temperature superconducting partial core transformer and fault current limiter as a single unit is highlighted.
The reverse design model is discussed followed by the model parameters that are used in designing the high temperature superconducting partial core transformer. Partial core transformers with copper windings and high temperature superconductor windings at the University of Canterbury were then tested and the measured results compared with the results calculated from the reverse design model, to validate the model. The high temperature superconducting partial core transformer failed during an endurance run and the investigation of the failure is then presented. The results of the failure investigation prompted an alternative winding insulation design. A model to calculate the time at which the high temperature superconducting winding of the partial core transformer would melt at different currents was then built. The time was calculated to be used in the operation of the quench detection mechanism and it could also be used in choosing a circuit breaker with a known operating time.
The design of the high temperature superconducting partial core transformer and fault current limiter is then presented. Design configurations with different core length and winding length are examined. The idea behind choosing the final design for the high temperature superconducting partial core transformer and fault current limiter is then discussed. The final design of the high temperature superconducting partial core transformer and fault current limiter is then presented.
A new 7.5 kVA, 230-248 V high temperature superconducting partial core transformer and fault current limiter was designed, built and tested. The windings are layer wound with first generation Bi2223 high temperature superconductor. A series of electrical tests were performed on the new device including open circuit, short circuit, resistive load, overload and fault ride through. These tests were performed to determine the operational characteristics of the new high temperature superconducting partial core transformer and fault current limiter. The measured results from the tests were compared with the calculated results. The fault ride through test results were then compared to a 15 kVA high temperature superconducting partial core transformer that was designed and built at the University of Canterbury. Since the resistive component of the silver matrix in Bi2223 high temperature superconductor plays a very little role in controlling the fault current, the current limited by the leakage reactance is compared between the two devices. The high temperature superconducting partial core transformer and fault current limiter was found to be 99.1% efficient at rated power with 5.7% regulation and fault current limiting ability of 500 % over the 15 kVA high temperature superconductor partial core transformer from University of Canterbury.
|
14 |
Analysis of Current Limiting and Recovery Characteristics of Superconducting Fault Current Limiting Transformer (SFCLT) with YBCO Coated ConductorsOkubo, H., Hanai, M., Kojima, H., Kito, T., Hayakawa, N. 06 1900 (has links)
No description available.
|
15 |
Current limitation and recovery function for superconducting fault current limiting transformer (SFCLT)Okubo, Hitoshi, Hanai, Masahiro, Hayakawa, Naoki, Kojima, Hiroki, Himbele, John 09 1900 (has links)
Superconductivity Centennial Conference 2011- EUCAS–ISEC–ICMC (18-23 Sep 2011, The Hague, The Netherlands)
|
16 |
Feasibility Study on a High-Temperature Superconducting Fault-Current-Limiting Cable (SFCLC) Using Flux-Flow ResistanceOkubo, Hitoshi, Hanai, Masahiro, Hayakawa, Naoki, Kato, Fumihiko, Kojima, Hiroki 04 1900 (has links)
No description available.
|
17 |
Feasibility Study of Superconducting Power Flow Controller and Fault Current Limiter (SPFCL)Sugimoto, S., Nagaya, S., Kashima, N., Okubo, H., Hanai, M., Kojima, H., Mao, X., Hayakawa, N. 06 1900 (has links)
No description available.
|
18 |
A system study on superconducting fault current limiting transformer (SFCLT) with the functions of fault current suppression and system stability improvementHayakawa, N., Kagawa, H., Okubo, H. 03 1900 (has links)
No description available.
|
19 |
Relation between critical current density and flux flow resistivity in Bi2223 bulk element for fault current limiterAritake, T., Noda, T., Shimizu, H., Yokomizu, Y., Matsumura, T., Murayama, N. 06 1900 (has links)
No description available.
|
20 |
Current Limiting and Recovery Characteristics of 2 MVA Class Superconducting Fault Current Limiting Transformer (SFCLT)Okubo, Hitoshi, Hanai, Masahiro, Hayakawa, Naoki, Kito, Toyoaki, Kotari, Masashi, Kojima, Hiroki 06 1900 (has links)
No description available.
|
Page generated in 0.0829 seconds