• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de um sistema de medição de baixo custo para a monitoração de alimentadores aéreos de distribuição de energia elétrica da classe 15 KV /

Pinheiro, José Ricardo Giordano. January 2011 (has links)
Orientador: José Alfredo Covolan Ulson / Banca: Rogério Andrade Flauzino / Banca: Mario Eduardo Bordon / Resumo: O sistema de distribuiçã de energia elétrica no Brasil é constituído, na grande maioria, de alimentadores aéreos na classe 15 kV sujeitos a muitos tipos de defeitos. Embora existam muitos trabalhos propondo técnicas para a identificação e a localização das faltas, a maioria deles foi desenvolvida objetivando as redes de transmissão pouco ramificadas. Em se tratando de redes muito ramificadas e extensas, características princiapais de redes de distribuição elétrica, esses métodos não apresentam alta confiabilidade e segurança em termos de detecção, dificultando a localização das faltas. Este trabalho tem como objetivo descrever o desenvolvimento de um sistema de medição de baixo custo voltado para a monitoração de alimentadores aéreosm de distribuição de energia elétrica, que possibilite a identificação e a localização de faltas bem como a avaliação da qualidade da energia elétrica fornecida. Para tal, uma rede de sensores sem fio no padrão IEEE 802.15.4 é utilizada para adquirir os dados de tensão e corrente de cada frase e, a partir do processamento dessas informações, possibilitar a identificação de um ramal sob falta e a determinação do seu tipo. Com a instação de mediadores em pontos onde a rede de distribuição se ramifica, o ramal sob falta pode ser localizado, reduzindo assim o tempo de desligamento e os custos de manutenção / Abstract: The system of eletrecity distribution in Brazil is made mostly of air handlers in the class 15 kV, subject to many kinds of defects. Although there are many papers proposing techniques for the identification and location of faults, most of them were developed aiming at the broadcast networks little branched. In terms of networks very extensive and branched, like in distribution networks, these methods have low reliability and safety in terms of detection, makind the location of faults difficult. This paper aims to describe the development of a measurment system focused on low-cost monitoring of overhead distribution feeders of electricity, allowing for the identification and location of faults and the quality of power supplied. For this purpose, a network of wireless sensors on the IEEE 208.15.4 is used for data acquisition of each phase voltage and current and from the processing of such information is possible to determine a faulted extension and identification of its type. With the installation of meters at points where the distribution networks branches, the faulted extension can be located, thereby reducing the shutdown time and maintenance costs / Mestre
2

Utilização de modelos de falhas e observadores de estado em estruturas reticuladas /

Watanabe, Larissa. January 2010 (has links)
Orientador: Gilberto Pechoto de Melo / Banca: Amarildo Tabone Paschoalini / Banca: Yukio Kobayashi / Resumo: Nos últimos anos, tem havido um grande interesse das indústrias no desenvolvimento de novas técnicas de detecção e localização de falhas, pois se preocupam cada vez mais com a segurança, havendo assim, a necessidade de supervisão e monitoramento dos sistemas para que as falhas sejam evitadas ou sanadas o mais rápido possível. Determinados parâmetros em sistemas reais como massa, rigidez e amortecimento, podem variar devido ao aparecimento de falhas ou ao próprio desgaste natural dos componentes. Um aparecimento de trincas pode provocar perdas econômicas ou até conduzir a situações perigosas com paradas abruptas das máquinas e/ou equipamentos. Através do auxílio de modelos teóricos bem definidos, métodos de identificação de parâmetros, observadores de estado e auxílio à decisão foi possível desenvolver uma metodologia para detecção e localização de trincas em estruturas reticuladas, dando ênfase às tridimensionais. Foi possível detectar e localizar a trinca já no seu início e acompanhar sua propagação para uma possível parada programada. Foi utilizada a metodologia dos observadores de estado, que pode reconstruir os estados não medidos ou os valores provenientes de pontos de difícil acesso no sistema. Foi construída uma estrutura reticulada no Laboratório para validação da metodologia desenvolvida e os resultados foram bastante satisfatórios / Abstract: In recent years there has been a great interest of industry in developing new techniques for detection and location of faults, because they worry more about security, so there is the need for supervision and monitoring systems so that failures are avoided or remedied as soon as possible. Certain parameters in real systems such as mass, stiffness and damping can vary due to some failures to own or wear and tear of components. An appearance of cracks can cause economic loss or even lead to dangerous situations with abrupt stopping of machines and/or equipment. Through the aid of well-defined theoretical models, methods of parameter identification, state observers and aid the decision was possible to develop a methodology for detecting and locating cracks in frame structures, emphasizing the three-dimensional. It was possible to detect and locate the crack already in its early stages and monitor its spread to a possible shutdown. Methodology was applied for observer status, which can reconstruct the unmeasured states or values from points of difficult access in the system. A reticulated structure was built at the Laboratory for validation of the methodology and the results were very satisfactory / Mestre
3

Modelo estocástico de programação matemática de alocação de medidores de tensão em alimentadores radiais de distribuição de energia elétrica para localização de faltas e monitoramento do perfil de tensão /

Bíscaro, André do Amaral Penteado. January 2009 (has links)
Orientador: José Roberto Sanches Mantovani / Banca: Jozué Vieira Filho / Banca: Arturo Suman Bretas / Resumo: Neste trabalho é proposta uma técnica de otimização para alocar medidores dispersos de tensão em alimentadores radiais aéreos de distribuição baseada na metaheurística Greedy Randomized Adaptive Search Procedure (GRASP), com o objetivo de melhorar o desempenho de algoritmos de localização de faltas que utilizam informações esparsas de tensão e, simultaneamente, fazer o controle em tempo real do nível de tensão do alimentador operando sob diferentes cenários. No modelo de programação proposto para alocar os medidores considera-se a natureza estocástica das variáveis envolvidas no problema relacionado com o estudo de contingências em sistemas de energia elétrica, ou seja: carregamento dos transformadores da rede no instante de ocorrência da falta, impedância de falta, probabilidade de falhas e erros de medição dos medidores dispersos de tensão, probabilidade de ocorrer qualquer um dos tipos de faltas possíveis, entre outros. O modelo da função objetivo contempla a localização de faltas com boa precisão para qualquer algoritmo que utiliza medições esparsas de tensão e os menores valores de magnitudes de tensão no alimentador, operando em condições normais ou sob contingências. Apresentam-se resultados de testes com a metodologia proposta para dois alimentadores reais de distribuição de energia elétrica. O primeiro alimentador é de médio porte, tensão nominal de 13,8 kV e possui 134 barras. O segundo alimentador é de grande porte, tensão nominal de 11,4 kV e possui 3287 barras. / Abstract: This work proposes an optimization technique to allocate voltage measurement devices on radial overhead electric power distribution feeders based on Greedy Randomized Adaptive Search Procedure (GRASP) metaheuristic, aiming at improving the performance of algorithms for fault location using sparse voltage information, while making the real time control of the feeder's operating voltage under different scenarios. The proposed programming model to allocate the devices considers the nature of the stochastic variables involved in the problem with the study of contingencies in electric power systems: loading of the network transformers at time of occurrence of failure, fault impedance, probability of failures and errors of measurement of dispersed voltage devices, likelihood that any of the possible types of faults occur, among others. The model's objective function includes the faults location procedure with good precision for any algorithm that uses sparse measurements of voltage and the lowest values of the magnitudes of voltage feeder, operating under normal conditions or contingencies. Test results with the proposed methodology applied to simulated data of two real life feeders are presented. The first feeder is medium size, rated voltage of 13.8 kV and has 134 bars. The second feeder is large, rated voltage of 11.4 kV and has 3287 bars. / Mestre

Page generated in 0.2596 seconds