Spelling suggestions: "subject:"fibrous bfilter"" "subject:"fibrous builter""
1 |
Filtration of solid and liquid aerosol particlesScurrah, Katherine Lesley January 1999 (has links)
Fibrous filter materials are commonly adopted in a variety of industrial and domestic processes to remove fine particles. Filter performance may be assessed by two parameters: the proportion of particles passing through the media (penetration), and the resistance to gas flow through the filter (pressure drop). Another parameter, the filter lifetime, may be important where economical factors are key.
|
2 |
Étude de l'évaporation d'aérosols liquides semi-volatils collectés sur médias fibreux / Study of the evaporation of liquid semi-volatil aerosols collected on fibrous filtersSutter, Benjamin 03 November 2009 (has links)
Cette étude s’inscrit dans le cadre de l’amélioration des connaissances liées à l’évaporation d’aérosols liquides semi-volatils collectés sur des filtres à fibres. Le phénomène d’évaporation d’aérosols collectés sur médias fibreux induit des problèmes de sécurité avec notamment une surexposition des salariés aux vapeurs, à l’aval des systèmes généraux de filtration de l’air. De plus, lors des contrôles des concentrations atmosphériques des aérosols, l’évaporation induit une sous-estimation de la phase particulaire de l’aérosol prélevé qui est problématique en termes de prévention de l’exposition. L’objectif de ces travaux a donc été de produire de nombreux résultats expérimentaux afin, d’une part, de compléter les rares présents dans la littérature et, d’autre part, d’améliorer les modèles théoriques développés précédemment. Deux approches expérimentales ont été menées afin d’identifier le processus d’évaporation d’un aérosol collecté. La première, nommée approche globale, permet de suivre l’évaporation de l’aérosol par la quantification des vapeurs à l’aval du filtre, au cours du temps. La seconde, nommée approche microscopique, étudie l’évaporation de gouttes collectées sur les fibres d’une fibre à l’échelle microscopique. Les deux approches réalisées lors de ces travaux s’accordent sur le fait que l’évaporation d’un aérosol liquide semi-volatil ne peut être modélisée par les modèles proposés par la littérature. Des hypothèses ont été avancées afin d’expliquer la divergence de cinétique d’évaporation entre la théorie et les expérimentations / This study falls within the scope of improving knowledge concerning evaporation of semi-volatile liquid aerosols collected on fibrous filters. Under these conditions, the aerosol evaporation phenomenon causes problems of safety, in particular over-exposure of employees to vapours downstream of general air filtering systems. Furthermore, when controlling aerosol atmospheric concentrations, evaporation results in under-estimation of the sampled aerosol particle phase and this is clearly problematic in exposure prevention terms. The aim of this work was therefore to record a large number of experimental data, both to make up for their scarcity in the literature and to improve previously developed theoretical models. Two experimental approaches were implemented to identify the evaporation process for a collected aerosol. The first, termed the global approach, allowed us to monitor aerosol evaporation by measuring vapour quantity downstream of the filter with respect to time. The second, microscopic, approach considers evaporation of droplets collected on the filter fibres on a microscopic scale. The two approaches implemented during this research lead to agreement on the fact that evaporation of a liquid semi-volatile aerosol cannot be satisfactorily represented by the theoretical models proposed in the literature. Hypotheses are advanced to explain the divergence in evaporation kinetics between theoretical and experimental work
|
3 |
Aerosol Droplet Migration in Fibrous MediaDavoudi, Masoume 21 November 2018 (has links)
No description available.
|
4 |
Nanofiber Filter Media for Air FiltrationRaghavan, Bharath Kumar 11 August 2010 (has links)
No description available.
|
Page generated in 0.0312 seconds