• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Fixador esquelético externo híbrido em fraturas metafisárias de rádio e tíbia em cães

Reis, Kauê Danilo Helene Lemos dos January 2015 (has links)
As fraturas de ossos longos são frequentes na rotina de pequenos animais, geralmente decorrentes de injúrias de alto impacto, como quedas, acidentes automobilísticos e projéteis. Os fixadores esqueléticos externos são versáteis, podendo ser utilizados em diferentes montagens, como linear, circular, híbrida, unilateral, bilateral, uniplanar, multiplanar, sendo amplamente utilizado em fraturas de rádio e tíbia. O presente trabalho avaliou a utilização de fixador esquelético externo híbrido (FEEH) em fraturas metafisárias de rádio e tíbia em cães atendidos na rotina do Hospital de Clínicas Veterinárias da Universidade Federal do Rio Grande Sul (HCV-UFRGS). Foram incluídos 13 animais neste estudo, cinco com fratura de tíbia e oito com fratura de rádio. Os FEEH, com anel inteiro ou semianel e uma barra, foram pré-montados de acordo com tamanho do animal e localização da fratura. Após redução, aberta ou fechada, foram inseridos os fios de Kirschner no fragmento curto, de maneira divergente, presos ao anel e três pinos de Shanz no fragmento longo fixados à barra por presilhas. Não houve intercorrências transoperatórias. Todos os casos atingiram a consolidação óssea. Os FEEH foram retirados entre cinco e 10 semanas de pós-operatório. As complicações encontradas foram tratos de drenagem (5), complicação resolvida reduzindo intervalo entre curativos, de semanal para diário, desvio angular (4), sendo dois com desvio valgo, um recurvatum e um tanto valgo quanto recurvatum quebra de fio (2), reação periosteal (2). Todos os animais apresentaram uso funcional do membro ao final do período de avaliação. O FEEH foi efetivo para o tratamento de fraturas metafisárias de rádio e tíbia na amostra estudada. / The presence of long bones fractured is often in pets’ routine, these fractures usually happen due to high impact injuries, as falling, automobile accidents and projectiles. The external skeletal fixators are versatile, then they can be used in different assemblies as linear, circle, hybrid, unilateral, bilateral, uniplanar and multiplanar, having wide requisition to radius and tibia. This paper evaluates the uses of hybrid external skeletal fixator (HESF) on metaphyseal fractures of radius and tibia in dogs that were rescued at Hospital of Veterinary Clinics at Federal University of Rio Grande do Sul (HCV-UFRGS). Thirteen dogs were evaluated: five presenting tibial fractures and eight showing radius fractures. The HESF, with full ring or semiring and a sidebar, were pre-assembled in accordance with animal size and fracture site. After reduction, open or closed, the Kirschner wire were inserted in the short fragment, divergently, fixed to the ring and three Schanz pins in large fragment, fixed to the bar. There were not intraoperative complications. All cases reached the bone healing. The HESF were taken off between five and ten weeks postoperative. The noted complications were: drainage tract (4), complication resolved reducing interval between dressings, weekly to daily, angular detour (4), two valgus, one recurvatum and one valgus and recurvatum, wire breaking (2) and periosteal reaction. At the end of evaluation period, all animals presented functional use of the member. In this studied sample, HESF was effective on treatment of metaphyseal fractures of radius and tibia.
2

Fixador esquelético externo híbrido em fraturas metafisárias de rádio e tíbia em cães

Reis, Kauê Danilo Helene Lemos dos January 2015 (has links)
As fraturas de ossos longos são frequentes na rotina de pequenos animais, geralmente decorrentes de injúrias de alto impacto, como quedas, acidentes automobilísticos e projéteis. Os fixadores esqueléticos externos são versáteis, podendo ser utilizados em diferentes montagens, como linear, circular, híbrida, unilateral, bilateral, uniplanar, multiplanar, sendo amplamente utilizado em fraturas de rádio e tíbia. O presente trabalho avaliou a utilização de fixador esquelético externo híbrido (FEEH) em fraturas metafisárias de rádio e tíbia em cães atendidos na rotina do Hospital de Clínicas Veterinárias da Universidade Federal do Rio Grande Sul (HCV-UFRGS). Foram incluídos 13 animais neste estudo, cinco com fratura de tíbia e oito com fratura de rádio. Os FEEH, com anel inteiro ou semianel e uma barra, foram pré-montados de acordo com tamanho do animal e localização da fratura. Após redução, aberta ou fechada, foram inseridos os fios de Kirschner no fragmento curto, de maneira divergente, presos ao anel e três pinos de Shanz no fragmento longo fixados à barra por presilhas. Não houve intercorrências transoperatórias. Todos os casos atingiram a consolidação óssea. Os FEEH foram retirados entre cinco e 10 semanas de pós-operatório. As complicações encontradas foram tratos de drenagem (5), complicação resolvida reduzindo intervalo entre curativos, de semanal para diário, desvio angular (4), sendo dois com desvio valgo, um recurvatum e um tanto valgo quanto recurvatum quebra de fio (2), reação periosteal (2). Todos os animais apresentaram uso funcional do membro ao final do período de avaliação. O FEEH foi efetivo para o tratamento de fraturas metafisárias de rádio e tíbia na amostra estudada. / The presence of long bones fractured is often in pets’ routine, these fractures usually happen due to high impact injuries, as falling, automobile accidents and projectiles. The external skeletal fixators are versatile, then they can be used in different assemblies as linear, circle, hybrid, unilateral, bilateral, uniplanar and multiplanar, having wide requisition to radius and tibia. This paper evaluates the uses of hybrid external skeletal fixator (HESF) on metaphyseal fractures of radius and tibia in dogs that were rescued at Hospital of Veterinary Clinics at Federal University of Rio Grande do Sul (HCV-UFRGS). Thirteen dogs were evaluated: five presenting tibial fractures and eight showing radius fractures. The HESF, with full ring or semiring and a sidebar, were pre-assembled in accordance with animal size and fracture site. After reduction, open or closed, the Kirschner wire were inserted in the short fragment, divergently, fixed to the ring and three Schanz pins in large fragment, fixed to the bar. There were not intraoperative complications. All cases reached the bone healing. The HESF were taken off between five and ten weeks postoperative. The noted complications were: drainage tract (4), complication resolved reducing interval between dressings, weekly to daily, angular detour (4), two valgus, one recurvatum and one valgus and recurvatum, wire breaking (2) and periosteal reaction. At the end of evaluation period, all animals presented functional use of the member. In this studied sample, HESF was effective on treatment of metaphyseal fractures of radius and tibia.
3

Fixador esquelético externo híbrido em fraturas metafisárias de rádio e tíbia em cães

Reis, Kauê Danilo Helene Lemos dos January 2015 (has links)
As fraturas de ossos longos são frequentes na rotina de pequenos animais, geralmente decorrentes de injúrias de alto impacto, como quedas, acidentes automobilísticos e projéteis. Os fixadores esqueléticos externos são versáteis, podendo ser utilizados em diferentes montagens, como linear, circular, híbrida, unilateral, bilateral, uniplanar, multiplanar, sendo amplamente utilizado em fraturas de rádio e tíbia. O presente trabalho avaliou a utilização de fixador esquelético externo híbrido (FEEH) em fraturas metafisárias de rádio e tíbia em cães atendidos na rotina do Hospital de Clínicas Veterinárias da Universidade Federal do Rio Grande Sul (HCV-UFRGS). Foram incluídos 13 animais neste estudo, cinco com fratura de tíbia e oito com fratura de rádio. Os FEEH, com anel inteiro ou semianel e uma barra, foram pré-montados de acordo com tamanho do animal e localização da fratura. Após redução, aberta ou fechada, foram inseridos os fios de Kirschner no fragmento curto, de maneira divergente, presos ao anel e três pinos de Shanz no fragmento longo fixados à barra por presilhas. Não houve intercorrências transoperatórias. Todos os casos atingiram a consolidação óssea. Os FEEH foram retirados entre cinco e 10 semanas de pós-operatório. As complicações encontradas foram tratos de drenagem (5), complicação resolvida reduzindo intervalo entre curativos, de semanal para diário, desvio angular (4), sendo dois com desvio valgo, um recurvatum e um tanto valgo quanto recurvatum quebra de fio (2), reação periosteal (2). Todos os animais apresentaram uso funcional do membro ao final do período de avaliação. O FEEH foi efetivo para o tratamento de fraturas metafisárias de rádio e tíbia na amostra estudada. / The presence of long bones fractured is often in pets’ routine, these fractures usually happen due to high impact injuries, as falling, automobile accidents and projectiles. The external skeletal fixators are versatile, then they can be used in different assemblies as linear, circle, hybrid, unilateral, bilateral, uniplanar and multiplanar, having wide requisition to radius and tibia. This paper evaluates the uses of hybrid external skeletal fixator (HESF) on metaphyseal fractures of radius and tibia in dogs that were rescued at Hospital of Veterinary Clinics at Federal University of Rio Grande do Sul (HCV-UFRGS). Thirteen dogs were evaluated: five presenting tibial fractures and eight showing radius fractures. The HESF, with full ring or semiring and a sidebar, were pre-assembled in accordance with animal size and fracture site. After reduction, open or closed, the Kirschner wire were inserted in the short fragment, divergently, fixed to the ring and three Schanz pins in large fragment, fixed to the bar. There were not intraoperative complications. All cases reached the bone healing. The HESF were taken off between five and ten weeks postoperative. The noted complications were: drainage tract (4), complication resolved reducing interval between dressings, weekly to daily, angular detour (4), two valgus, one recurvatum and one valgus and recurvatum, wire breaking (2) and periosteal reaction. At the end of evaluation period, all animals presented functional use of the member. In this studied sample, HESF was effective on treatment of metaphyseal fractures of radius and tibia.
4

Fixador esquelético externo circular para o tratamento de fraturas rádio e tíbia em cães

Gonzalez, Paula Cristina Sieczkowski January 2013 (has links)
O fixador esquelético externo circular foi desenvolvido durante a guerra fria na Rússia, pelo Professor Gavril Abramovich Ilizarov. Esse tipo de fixação ganhou espaço como alternativa à fixação interna, devido a sua versatilidade e às suas características biomecânicas que otimizam a formação do calo ósseo. O objetivo desse estudo foi avaliar o fixador esquelético externo circular como método de fixação para fraturas metafisárias de rádio e tíbia de cães atendidos no Hospital de Clínicas Veterinárias da UFRGS. Os resultados a respeito do tipo e frequência de complicações associados a essa técnica foram documentados. No total 16 animais cumpriram os critérios para entrar no estudo sendo sete fêmeas e nove machos. A idade média dos animais foi de 50,87 ± 57,01 meses com peso médio dos animais foi de 8,6 ± 6,95kg. Três (18%) animais apresentaram fratura de tíbia e fíbula e treze (82%) fraturas de rádio e ulna. O aparelho de fixação esquelética utilizado consistiu de um aro proximal 5/8 e dois aros distais inteiros, com dois fios em cada anel. Os fios foram colocados de maneira divergente o mais próximo possível de 90°. O aparelho pesou em média 128 ± 49g, representando em média 4,09 ± 3,22% do peso do animal. O tempo médio de cirurgia foi de 115 ± 32 minutos. O tempo médio de permanência com o aparelho de fixação esquelética externa circular foi de 81,69 ± 23,14 dias. Entre as complicações encontradas estão: tratos de drenagem ao redor dos fios (37,5%), miíase (6,25%), encurtamento dos músculos flexores do antebraço (6,25%), hemorragia associada ao local de passagens dos pinos (6,25%) e quebra do fio com deslocamento do fixador levando a necessidade de sua remoção (6,25%). Não houve diferença estatística entre os tempos cirúrgicos necessários para a osteossíntese de rádio e tíbia. Não houve correlação entre as variáveis: tempo decorrido do trauma até a cirurgia e tempo de duração da cirurgia; tempo decorrido do trauma até a cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular; peso do animal e duração da cirurgia; proporção do peso do circular em relação ao peso do animal e o tempo de permanecia com o circular. Houve correlação positiva estatisticamente significativa entre as variáveis: duração da cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular. Essa modalidade de tratamento representa uma opção cirúrgica atrativa para a correção de fraturas de rádio e tíbia em cães, entretanto, devido à possibilidade complicações e necessidade de cuidados pós-operatórios intensivos uma seleção acurada dos pacientes e proprietários deve ser realizada previamente à cirurgia. / The circular external skeletal fixator was developed during the Cold War in Russia, by Professor Gavril Abramovich Ilizarov. This kind of fixation took place as an alternative to internal fixation, due to its versatility and its biomechanical characteristics that improves the formation of callus. The aim of this study was to evaluate the circular external skeletal fixator as a method of fixation for fractures of the radius and tibia of dogs treated at the Veterinary Teaching Hospital of UFRGS, corroborating the results, the type and frequency of complications associated with this technique. Sixteen animals met the criteria to participate on the study, seven females and nine males. The average age of the animals was 50.87 ± 57.01 months. The average weight of the animals was 8.6 ± 6.95 kg. Three (18%) animals showed fracture of tibia and fibula and thirteen (82%) fractures of the radius and ulna. The circular external skeletal fixation frame used consisted of a proximal ring ⅝ and two full distal rings, with two wires in each ring. The wires were placed divergently as close as possible to 90 °. The frame weighed on average 128 ± 49g, representing average 4.09 ± 3.22% of the weight of the animal. The mean time of the surgery was 115 ± 32 minutes. The average time spent with the circular was 81.69 ± 23.14 days. Among the complications found are drainage tracts around the pins (37.5%), myiasis (6.25%), shortening of the forearm flexors (6.25%), hemorrhage associated with the location of pins passages (6, 25%) and breakage of the device wire with displacement of the frame leading to its removal (6.25%). There was no statistical difference between the times required for the surgical fixation of the radius and tibia. There was no correlation between the variables: time elapsed from trauma to surgery and duration of surgery, time elapsed from trauma to surgery and time spent with the circular external skeletal fixation; animal weight and duration of surgery; the proportion of the circular weight in relation to the weight of the animal and the time remained with the circular. There was statistically significant positive correlation between the variables: duration of the surgery and the permanency with the circular external skeletal fixation. This treatment modality represents an attractive surgical option for fractures correction of the radius and tibia in dogs, however, due to possible complications and need for intensive post operative care accurate selection of patients and owners should be performed prior to surgery.
5

Fixador esquelético externo circular para o tratamento de fraturas rádio e tíbia em cães

Gonzalez, Paula Cristina Sieczkowski January 2013 (has links)
O fixador esquelético externo circular foi desenvolvido durante a guerra fria na Rússia, pelo Professor Gavril Abramovich Ilizarov. Esse tipo de fixação ganhou espaço como alternativa à fixação interna, devido a sua versatilidade e às suas características biomecânicas que otimizam a formação do calo ósseo. O objetivo desse estudo foi avaliar o fixador esquelético externo circular como método de fixação para fraturas metafisárias de rádio e tíbia de cães atendidos no Hospital de Clínicas Veterinárias da UFRGS. Os resultados a respeito do tipo e frequência de complicações associados a essa técnica foram documentados. No total 16 animais cumpriram os critérios para entrar no estudo sendo sete fêmeas e nove machos. A idade média dos animais foi de 50,87 ± 57,01 meses com peso médio dos animais foi de 8,6 ± 6,95kg. Três (18%) animais apresentaram fratura de tíbia e fíbula e treze (82%) fraturas de rádio e ulna. O aparelho de fixação esquelética utilizado consistiu de um aro proximal 5/8 e dois aros distais inteiros, com dois fios em cada anel. Os fios foram colocados de maneira divergente o mais próximo possível de 90°. O aparelho pesou em média 128 ± 49g, representando em média 4,09 ± 3,22% do peso do animal. O tempo médio de cirurgia foi de 115 ± 32 minutos. O tempo médio de permanência com o aparelho de fixação esquelética externa circular foi de 81,69 ± 23,14 dias. Entre as complicações encontradas estão: tratos de drenagem ao redor dos fios (37,5%), miíase (6,25%), encurtamento dos músculos flexores do antebraço (6,25%), hemorragia associada ao local de passagens dos pinos (6,25%) e quebra do fio com deslocamento do fixador levando a necessidade de sua remoção (6,25%). Não houve diferença estatística entre os tempos cirúrgicos necessários para a osteossíntese de rádio e tíbia. Não houve correlação entre as variáveis: tempo decorrido do trauma até a cirurgia e tempo de duração da cirurgia; tempo decorrido do trauma até a cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular; peso do animal e duração da cirurgia; proporção do peso do circular em relação ao peso do animal e o tempo de permanecia com o circular. Houve correlação positiva estatisticamente significativa entre as variáveis: duração da cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular. Essa modalidade de tratamento representa uma opção cirúrgica atrativa para a correção de fraturas de rádio e tíbia em cães, entretanto, devido à possibilidade complicações e necessidade de cuidados pós-operatórios intensivos uma seleção acurada dos pacientes e proprietários deve ser realizada previamente à cirurgia. / The circular external skeletal fixator was developed during the Cold War in Russia, by Professor Gavril Abramovich Ilizarov. This kind of fixation took place as an alternative to internal fixation, due to its versatility and its biomechanical characteristics that improves the formation of callus. The aim of this study was to evaluate the circular external skeletal fixator as a method of fixation for fractures of the radius and tibia of dogs treated at the Veterinary Teaching Hospital of UFRGS, corroborating the results, the type and frequency of complications associated with this technique. Sixteen animals met the criteria to participate on the study, seven females and nine males. The average age of the animals was 50.87 ± 57.01 months. The average weight of the animals was 8.6 ± 6.95 kg. Three (18%) animals showed fracture of tibia and fibula and thirteen (82%) fractures of the radius and ulna. The circular external skeletal fixation frame used consisted of a proximal ring ⅝ and two full distal rings, with two wires in each ring. The wires were placed divergently as close as possible to 90 °. The frame weighed on average 128 ± 49g, representing average 4.09 ± 3.22% of the weight of the animal. The mean time of the surgery was 115 ± 32 minutes. The average time spent with the circular was 81.69 ± 23.14 days. Among the complications found are drainage tracts around the pins (37.5%), myiasis (6.25%), shortening of the forearm flexors (6.25%), hemorrhage associated with the location of pins passages (6, 25%) and breakage of the device wire with displacement of the frame leading to its removal (6.25%). There was no statistical difference between the times required for the surgical fixation of the radius and tibia. There was no correlation between the variables: time elapsed from trauma to surgery and duration of surgery, time elapsed from trauma to surgery and time spent with the circular external skeletal fixation; animal weight and duration of surgery; the proportion of the circular weight in relation to the weight of the animal and the time remained with the circular. There was statistically significant positive correlation between the variables: duration of the surgery and the permanency with the circular external skeletal fixation. This treatment modality represents an attractive surgical option for fractures correction of the radius and tibia in dogs, however, due to possible complications and need for intensive post operative care accurate selection of patients and owners should be performed prior to surgery.
6

Fixador esquelético externo circular para o tratamento de fraturas rádio e tíbia em cães

Gonzalez, Paula Cristina Sieczkowski January 2013 (has links)
O fixador esquelético externo circular foi desenvolvido durante a guerra fria na Rússia, pelo Professor Gavril Abramovich Ilizarov. Esse tipo de fixação ganhou espaço como alternativa à fixação interna, devido a sua versatilidade e às suas características biomecânicas que otimizam a formação do calo ósseo. O objetivo desse estudo foi avaliar o fixador esquelético externo circular como método de fixação para fraturas metafisárias de rádio e tíbia de cães atendidos no Hospital de Clínicas Veterinárias da UFRGS. Os resultados a respeito do tipo e frequência de complicações associados a essa técnica foram documentados. No total 16 animais cumpriram os critérios para entrar no estudo sendo sete fêmeas e nove machos. A idade média dos animais foi de 50,87 ± 57,01 meses com peso médio dos animais foi de 8,6 ± 6,95kg. Três (18%) animais apresentaram fratura de tíbia e fíbula e treze (82%) fraturas de rádio e ulna. O aparelho de fixação esquelética utilizado consistiu de um aro proximal 5/8 e dois aros distais inteiros, com dois fios em cada anel. Os fios foram colocados de maneira divergente o mais próximo possível de 90°. O aparelho pesou em média 128 ± 49g, representando em média 4,09 ± 3,22% do peso do animal. O tempo médio de cirurgia foi de 115 ± 32 minutos. O tempo médio de permanência com o aparelho de fixação esquelética externa circular foi de 81,69 ± 23,14 dias. Entre as complicações encontradas estão: tratos de drenagem ao redor dos fios (37,5%), miíase (6,25%), encurtamento dos músculos flexores do antebraço (6,25%), hemorragia associada ao local de passagens dos pinos (6,25%) e quebra do fio com deslocamento do fixador levando a necessidade de sua remoção (6,25%). Não houve diferença estatística entre os tempos cirúrgicos necessários para a osteossíntese de rádio e tíbia. Não houve correlação entre as variáveis: tempo decorrido do trauma até a cirurgia e tempo de duração da cirurgia; tempo decorrido do trauma até a cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular; peso do animal e duração da cirurgia; proporção do peso do circular em relação ao peso do animal e o tempo de permanecia com o circular. Houve correlação positiva estatisticamente significativa entre as variáveis: duração da cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular. Essa modalidade de tratamento representa uma opção cirúrgica atrativa para a correção de fraturas de rádio e tíbia em cães, entretanto, devido à possibilidade complicações e necessidade de cuidados pós-operatórios intensivos uma seleção acurada dos pacientes e proprietários deve ser realizada previamente à cirurgia. / The circular external skeletal fixator was developed during the Cold War in Russia, by Professor Gavril Abramovich Ilizarov. This kind of fixation took place as an alternative to internal fixation, due to its versatility and its biomechanical characteristics that improves the formation of callus. The aim of this study was to evaluate the circular external skeletal fixator as a method of fixation for fractures of the radius and tibia of dogs treated at the Veterinary Teaching Hospital of UFRGS, corroborating the results, the type and frequency of complications associated with this technique. Sixteen animals met the criteria to participate on the study, seven females and nine males. The average age of the animals was 50.87 ± 57.01 months. The average weight of the animals was 8.6 ± 6.95 kg. Three (18%) animals showed fracture of tibia and fibula and thirteen (82%) fractures of the radius and ulna. The circular external skeletal fixation frame used consisted of a proximal ring ⅝ and two full distal rings, with two wires in each ring. The wires were placed divergently as close as possible to 90 °. The frame weighed on average 128 ± 49g, representing average 4.09 ± 3.22% of the weight of the animal. The mean time of the surgery was 115 ± 32 minutes. The average time spent with the circular was 81.69 ± 23.14 days. Among the complications found are drainage tracts around the pins (37.5%), myiasis (6.25%), shortening of the forearm flexors (6.25%), hemorrhage associated with the location of pins passages (6, 25%) and breakage of the device wire with displacement of the frame leading to its removal (6.25%). There was no statistical difference between the times required for the surgical fixation of the radius and tibia. There was no correlation between the variables: time elapsed from trauma to surgery and duration of surgery, time elapsed from trauma to surgery and time spent with the circular external skeletal fixation; animal weight and duration of surgery; the proportion of the circular weight in relation to the weight of the animal and the time remained with the circular. There was statistically significant positive correlation between the variables: duration of the surgery and the permanency with the circular external skeletal fixation. This treatment modality represents an attractive surgical option for fractures correction of the radius and tibia in dogs, however, due to possible complications and need for intensive post operative care accurate selection of patients and owners should be performed prior to surgery.

Page generated in 0.0727 seconds