• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Experimental investigation of a meso-scale axial flow pump

Bice, Jonathon Ray, January 2009 (has links)
Thesis (M.S.)--University of Texas at El Paso, 2009. / Title from title screen. Vita. CD-ROM. Includes bibliographical references. Also available online.
2

Investigation on the flow dynamics of mesoscale inlet guide vanes

Cobian, Marcela Ivonne, January 2008 (has links)
Thesis (M.S.)--University of Texas at El Paso, 2008. / Title from title screen. Vita. CD-ROM. Includes bibliographical references. Also available online.
3

Estudo de viabilidade de atuadores piezelétricos bilaminares para bombeamento de líquidos. / Viability study of bilaminar piezoelectric actuators for liquid pumping.

Vatanabe, Sandro Luis 27 November 2008 (has links)
As bombas de fluxo, além das aplicações clássicas em Engenharia, são instrumentos importantes em áreas como a Bioengenharia, seja para o bombeamento de sangue ou dosagem de reagentes e medicamentos, e na área de refrigeração de equipamentos eletrônicos. Muitos dos novos princípios aplicados no desenvolvimento desse tipo de bomba de fluxo baseiam-se no uso de atuadores piezelétricos. Esses atuadores apresentam certas vantagens em relação a outros tipos tradicionalmente utilizados, como maior potencial de miniaturização, menor geração de ruídos e número reduzido de partes móveis. Entre os vários tipos de bombas de fluxo piezelétricas destacam-se as baseadas nos movimentos ondulatórios e oscilatórios, como o nadar dos peixes. É bem conhecido que os peixes ao nadarem não provocam a morte de micro-organismos ao seu redor, o que torna esse princípio bem promissor para as aplicações em Biotecnologia, por exemplo. Assim, o presente trabalho de mestrado dedica-se ao estudo de novas configurações de atuadores piezelétricos bilaminares associados em paralelo e série para bombeamento de líquidos através do princípio oscilatório, a fim de se obter maiores vazões ou pressões. O escopo deste projeto abrange, computacionalmente, análises estruturais de atuadores piezelétricos bilaminares e simulações do escoamento de fluido e, experimentalmente, construções de protótipos para validação de resultados. Inicialmente é investigado o comportamento de um único atuador piezelétrico bilaminar em fluido viscoso (água), a fim de se dominar o princípio de funcionamento proposto neste trabalho. Esse estudo serviu de referência para as configurações de atuadores em série e paralelo propostas. Espera-se que a configuração dos atuadores em paralelo apresente um ganho na vazão de saída, enquanto que a configuração dos atuadores em série apresente um ganho na pressão de saída. Ao longo desta dissertação são apresentadas a metodologia empregada e as discussões dos resultados obtidos, de forma a analisar o princípio proposto e os fenômenos físicos em questão. / Flow pumps, in addition to traditional applications in Engineering, are important tools in areas such as Bioengineering, applied to blood pumping, dosage of medicine and chemical reagents, and in the field of thermal management solutions for electronic devices. Many of the new principles in flow pumps development are based on the use of piezoelectric actuators. These actuators present some advantages in relation to other applied types, for example, miniaturization potential, lower noise generation and fewer numbers of moving parts. Flow pumps based on undulatory and oscillatory movements, such as fish swimming, stand out among the various types of piezoelectric flow pumps. It is well known that fish swimming does not cause the death of microorganisms, what makes this principle applicable in Biotechnology, for example. Thus, the objective of this work is to study parallel-cascade configurations of bimorph piezoelectric actuators for liquid pumping based on the oscillatory principle, in order to obtain higher flow rates and pressure. The scope of this work includes structural and analyses of bimorph piezoelectric actuators and fluid flow simulations, and construction of prototypes for result validation. First, it is investigated the behavior of a single bimorph piezoelectric actuator oscillating in viscous fluid (water) to better understand the working principle used in this work. The study of a single piezoelectric actuator was used as a reference for the other proposed parallel-cascade configurations of actuators. It is expected that parallel actuators achieve higher flow rates, while the series actuators achieve higher pressures. The methods employed are presented and the obtained results are discussed, analyzing the principle and the related physical phenomena.
4

Estudo de viabilidade de atuadores piezelétricos bilaminares para bombeamento de líquidos. / Viability study of bilaminar piezoelectric actuators for liquid pumping.

Sandro Luis Vatanabe 27 November 2008 (has links)
As bombas de fluxo, além das aplicações clássicas em Engenharia, são instrumentos importantes em áreas como a Bioengenharia, seja para o bombeamento de sangue ou dosagem de reagentes e medicamentos, e na área de refrigeração de equipamentos eletrônicos. Muitos dos novos princípios aplicados no desenvolvimento desse tipo de bomba de fluxo baseiam-se no uso de atuadores piezelétricos. Esses atuadores apresentam certas vantagens em relação a outros tipos tradicionalmente utilizados, como maior potencial de miniaturização, menor geração de ruídos e número reduzido de partes móveis. Entre os vários tipos de bombas de fluxo piezelétricas destacam-se as baseadas nos movimentos ondulatórios e oscilatórios, como o nadar dos peixes. É bem conhecido que os peixes ao nadarem não provocam a morte de micro-organismos ao seu redor, o que torna esse princípio bem promissor para as aplicações em Biotecnologia, por exemplo. Assim, o presente trabalho de mestrado dedica-se ao estudo de novas configurações de atuadores piezelétricos bilaminares associados em paralelo e série para bombeamento de líquidos através do princípio oscilatório, a fim de se obter maiores vazões ou pressões. O escopo deste projeto abrange, computacionalmente, análises estruturais de atuadores piezelétricos bilaminares e simulações do escoamento de fluido e, experimentalmente, construções de protótipos para validação de resultados. Inicialmente é investigado o comportamento de um único atuador piezelétrico bilaminar em fluido viscoso (água), a fim de se dominar o princípio de funcionamento proposto neste trabalho. Esse estudo serviu de referência para as configurações de atuadores em série e paralelo propostas. Espera-se que a configuração dos atuadores em paralelo apresente um ganho na vazão de saída, enquanto que a configuração dos atuadores em série apresente um ganho na pressão de saída. Ao longo desta dissertação são apresentadas a metodologia empregada e as discussões dos resultados obtidos, de forma a analisar o princípio proposto e os fenômenos físicos em questão. / Flow pumps, in addition to traditional applications in Engineering, are important tools in areas such as Bioengineering, applied to blood pumping, dosage of medicine and chemical reagents, and in the field of thermal management solutions for electronic devices. Many of the new principles in flow pumps development are based on the use of piezoelectric actuators. These actuators present some advantages in relation to other applied types, for example, miniaturization potential, lower noise generation and fewer numbers of moving parts. Flow pumps based on undulatory and oscillatory movements, such as fish swimming, stand out among the various types of piezoelectric flow pumps. It is well known that fish swimming does not cause the death of microorganisms, what makes this principle applicable in Biotechnology, for example. Thus, the objective of this work is to study parallel-cascade configurations of bimorph piezoelectric actuators for liquid pumping based on the oscillatory principle, in order to obtain higher flow rates and pressure. The scope of this work includes structural and analyses of bimorph piezoelectric actuators and fluid flow simulations, and construction of prototypes for result validation. First, it is investigated the behavior of a single bimorph piezoelectric actuator oscillating in viscous fluid (water) to better understand the working principle used in this work. The study of a single piezoelectric actuator was used as a reference for the other proposed parallel-cascade configurations of actuators. It is expected that parallel actuators achieve higher flow rates, while the series actuators achieve higher pressures. The methods employed are presented and the obtained results are discussed, analyzing the principle and the related physical phenomena.

Page generated in 0.0699 seconds