Spelling suggestions: "subject:"fluxo dde potencial ótima"" "subject:"fluxo dde potencial ótica""
1 |
Técnicas de otimização aplicadas a sistemas elétricos de distribuição / Applied techniques of optimization on electrical distribution systemsCosta, Jeferson de Souza 29 August 2008 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-10-17T14:53:09Z
No. of bitstreams: 1
jefersondesouzacosta.pdf: 1000995 bytes, checksum: 7bb260f50fba7d0f3aebccb477e2d4a6 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-10-25T11:59:46Z (GMT) No. of bitstreams: 1
jefersondesouzacosta.pdf: 1000995 bytes, checksum: 7bb260f50fba7d0f3aebccb477e2d4a6 (MD5) / Made available in DSpace on 2016-10-25T11:59:46Z (GMT). No. of bitstreams: 1
jefersondesouzacosta.pdf: 1000995 bytes, checksum: 7bb260f50fba7d0f3aebccb477e2d4a6 (MD5)
Previous issue date: 2008-08-29 / Este trabalho apresenta três técnicas para otimização de sistemas de distribuição de energia elétrica (SDE) utilizando-se fluxo de potência ótimo baseado na metodologia primal-dual de pontos interiores. O objetivo consiste em obter o mínimo de perdas de potência ativa nos alimentadores. As técnicas são baseadas em um algoritmo para reconfiguração da rede radial, um modelo para localização ótima de capacitores e ajuste dos tapes dos reguladores de tensão.
Os problemas de otimização obtidos são de natureza não linear inteira mista, as variáveis discretas são representadas por funções continuas e os limites físicos e operativos do sistema são considerados. O tratamento das variáveis discretas é formulado através de um modelo heurístico construtivo baseado nos coeficientes de Lagrange.
As técnicas propostas são aplicadas a diversos sistemas da literatura e também a um sistema real de grande porte. / This work presents three techniques for optimization of systems of distribution of electric energy using optimal power flow based in the primal-dual methodology of interior points. The objective consists of getting the minimum of losses of active power in the feeders. The techniques are based on an algorithm for reconfiguration of the radial distribution feeders, a model for optimal localization of capacitors and taps adjustment of the voltage regulators.
The gotten problems of optimization are of nature not linear mixing entire, the discrete variable are represented by functions continue and the physical and operative limits of the system are considered. The treatment of the discrete variable is formulated through a heuristic model step by step based in the coefficients of Lagrange.
The techniques proposals are applied the diverse systems of the technical literature and also to a real large scale distribution system.
|
2 |
INTEGRAÇÃO DE METODOLOGIAS PARA AVALIAÇÃO DO CUSTO DA SEGURANÇA DINÂMICA EM MERCADOS ELÉTRICOS / INTEGRATION OF METHODOLOGY FOR EVALUATION OF THE COST OF SECURITY DYNAMICS IN ELECTRIC MARKETRodriguez, Jorge Isaac Rodriguez 28 February 2005 (has links)
Made available in DSpace on 2016-08-17T14:52:56Z (GMT). No. of bitstreams: 1
Jorge Isaac Rodriguez Rodriguez.pdf: 1323419 bytes, checksum: 4200a77bd6a2f02a314bd07b92e57da8 (MD5)
Previous issue date: 2005-02-28 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / In this work a framework for development of electric energy systems applications is proposed, on which several methodologies of analysis can be integrated or be adapted. An application of that framework has been developed to quantify the economic aspect for the improvement of power systems dynamic security based on preventive control. The following methodologies have been integrated for this objective: power systems dynamic security assessment, calculation of preventive control measures for dynamic security improvement and economic quantification of the impact caused by the application of those measures. Dynamic security assessment function uses a fast methodology based on transient energy function for contingencies dynamic ranking and a time-domain based methodology for the dynamic evaluation of contingencies. This last function has been implemented using a distributed processing environment. The power system dynamic security level is defined according to heuristic criteria which will determine the need of application of some control measure. The preventive control measures are defined when establishing the maximum limits of generation; those measures are calculated with fast methods without the use of sensitivities. Power system operation feasibility considering the new generation limits is obtained using a non linear optimal power flow program (OPF) with an objective function of load shedding minimization. The new operation condition of the power system is calculated following technical and economic considerations with the use of an OPF for several objective functions. The framework was projected using object-oriented methodology and CORBA (common object request broker architecture) architecture and has been coded in C++ and Java languages. Complete implementation of the described methodologies has been successfully tested with the Anderson-Fouad WECC-3 generators system and with a configuration of 44 generators of the interconnected Brazilian system. Analysis of results indicates that preventive control allows an improvement of power system dynamic security and a corresponding reduction in the economic impact after the occurrence of severe disturbances. / Neste trabalho é proposto um framework para desenvolvimento de aplicações elétricas, sobre o qual podem ser implementadas ou adaptadas distintas metodologias de análise, conseguindo que trabalhem em forma integrada para a quantificação do impacto econômico da melhoria da segurança dinâmica de sistemas elétricos. As metodologias incluem a avaliação da segurança dinâmica de sistemas de energia elétrica, o cálculo de medidas de controle preventivas para a melhoria dos níveis de segurança dinâmica e a quantificação do impacto econômico produzido pela aplicação de ditas medidas. Na avaliação da segurança dinâmica utiliza-se uma metodologia baseada na função de energia transitória para o ordenamento dinâmico de contingências e uma metodologia baseada no domínio do tempo para a avaliação dinâmica de contingências, esta última dentro de um ambiente de processamento paralelo. O nível de segurança dinâmica do sistema é estabelecido seguindo critérios heurísticos que determinarão a necessidade da aplicação de alguma medida de controle. As medidas de controle preventivo são definidas ao estabelecer os limites máximos de geração, calculados com métodos rápidos, sem o uso de sensibilidades. A factibilidade da operação do sistema considerando estes novos limites de geração é obtida com a utilização de um fluxo de potência ótimo não linear (FPO) e uma função objetivo de minimização de corte de carga. O novo ponto de operação é calculado segundo considerações técnico - econômicas com a utilização de um FPO para diferentes funções objetivo. O framework foi projetado utilizando metodologia orientada a objetos e uma arquitetura CORBA (common object request broker architecture), e codificado nas linguagens C++ e Java. A implementação total das metodologias descritas foi testada com sucesso no sistema Anderson-Fouad WECC de 3 geradores e numa configuração do sistema interligado brasileiro de 44 geradores. A análise dos resultados indica que o controle preventivo permite uma melhoria da segurança dinâmica do sistema de potência e uma correspondente diminuição no impacto econômico após a ocorrência de perturbações severas.
|
Page generated in 0.058 seconds