Development of a Dynamic Fouling Model for a Heat Exchanger

Zahid, Khayyam, Patel, Rajnikant, Mujtaba, Iqbal M. January 2016 (has links)
yes / Fouling in heat exchangers (HE) is a major problem in industry and accurate prediction of the onset or degree of fouling would be of a huge benefit to the operators. Modelling of the fouling phenomenon however, remains a challenging field of study. Cleaning of heat exchangers, coulpled with the down time, is a financial burden and for industrialized nations and costs can reach to almost 0.25 % of the country’s Gross National Product (Pritchard, 1988).This work presents the development of a dynamic fouling model based on experimental data collected using a laboratory concentric tube heat exchanger handling a saline system. Heat transfer coefficients were obtained from first principles as well as from either the Sieder-Tate or Petukhov-Kirillov correlations modified by Gnielinski depending on the flow regime. The outlet temperatures were calculated using the Effectiveness-NTU method. The dynamic fouling factor was based on the Kern and Seaton fouling model and validation was completed by comparing the experimental outlet temperatures with those predicted by the model. The model predicts the outlet temperatures with an average discrepancy of 1.6 °C and 0.4 °C for the cold and hot streams respectively.
2

Dynamic modelling of Heat Exchanger fouling in multistage flash (MSF) desalination

Alsadaie, S.M., Mujtaba, Iqbal M. 24 January 2017 (has links)
Yes / Fouling on heat transfer surfaces due to scale formation is the most concerned item in thermal desalination industry. Here, a dynamic fouling model is developed and incorporated into the MSF dynamic process model to predict fouling at high temperature and high velocity. The proposed dynamic model considers the attachment and removal mechanisms in the fouling phenomena with more relaxation of the assumptions such as the density of the fouling layer and salinity of the recycle brine. While calcium sulphate might precipitate at very high temperature, only the crystallization of calcium carbonate and magnesium hydroxide are considered in this work. Though the model is applied in a 24 stages brine recycle MSF plant, only the heat recovery section (21 stages) is considered under this study. The effect of flow velocity and surface temperature are investigated. By including both diffusion and reaction mechanism in the fouling model, the results of the fouling prediction model are in good agreement with most recent studies in the literature. The deposition of magnesium hydroxide increases with the increase in surface temperature and flow velocity while calcium carbonate deposition increases with the increase in the surface temperature and decreases with the increase in the flow velocity.
3

Crystallization of calcium carbonate and magnesium hydroxide in the heat exchangers of once-through multistage flash (MSF-OT) desalination process

Alsadaie, S., Mujtaba, Iqbal M. 25 August 2018 (has links)
Yes / In this paper, a dynamic model of fouling is presented to predict the crystallization of calcium carbonate and magnesium hydroxide inside the condenser tubes of Once-Through Multistage Flash (MSF-OT) desalination process. The model considers the combination of kinetic and mass diffusion rates taking into account the effect of temperature, velocity and salinity of the seawater. The equations for seawater carbonate system are used to calculate the concentration of the seawater species. The effects of salinity and temperature on the solubility of calcium carbonate and magnesium hydroxide are also considered. The results reveal an increase in the fouling inside the tubes caused by crystallization of CaCO3 and Mg(OH)2 with increase in the stage temperature. The intake seawater temperature and the Top Brine Temperature (TBT) are varied to investigate their impact on the fouling process. The results show that the (TBT) has greater impact than the seawater temperature on increasing the fouling.
4

Design and operation of multistage flash (MSF) desalination : advanced control strategies and impact of fouling : design operation and control of multistage flash desalination processes : dynamic modelling of fouling, effect of non-condensable gases on venting system design and implementation of GMC and fuzzy control

Alsadaie, Salih M. M. January 2017 (has links)
The rapid increase in the demand on fresh water due the increase in the world population and scarcity of natural water puts more stress on the desalination industrial sector to install more desalination plants around the world. Among these desalination plants, multistage flash desalination process (MSF) is considered to be the most reliable technique of producing potable water from saline water. In recent years, however, the MSF process is confronting many problems to cut off the cost and increase its performance. Among these problems are the non-condensable gases (NCGs) and the accumulation of fouling which they work as heat insulation materials. As a result, the MSF pumps and the heat transfer equipment are overdesigned and consequently increase the capital cost and decrease the performance of the plants. Moreover, improved process control is a cost effective approach to energy conservation and increased process profitability. Thus, this study is motivated by the real absence of detailed kinetic fouling model and implementation of advance process control (APC). To accomplish the above tasks, commercial modelling tools can be utilized to model and simulate MSF process taking into account the NCGs and fouling effect, and optimum control strategy. In this research, gPROMS (general PROcess Modeling System) model builder has been used to develop the MSF process model. First, a dynamic mathematical model of MSF is developed based on the basic laws of mass balance, energy balance and heat transfer. Physical and thermodynamic properties of brine, distillate and water vapour are included to support the model. The model simulation results are validated against actual plant data published in the literature and good agreement with these data is obtained. Second, the design of venting system in MSF plant and the effect of NCGs on the overall heat transfer coefficient (OHTC) are studied. The release rate of NCGs is studied using Henry’s law and the locations of venting points are optimised. The results reveal that high concentration of NCGs heavily affects the OHTC. Furthermore, advance control strategy namely: generic model control (GMC) is designed and introduced to the MSF process to control and track the set points of the two most important variables in the MSF plant; namely the Top Brine Temperature (TBT) which is the output temperature of the brine heater and the Brine Level (BL) in the last stage. The results are compared to conventional Proportional Integral Derivative Controller (PID) and show that GMC controller provides better performance over conventional PID controller to handle a nonlinear system. In addition, a new control strategy called hybrid Fuzzy-GMC is developed and implemented to control the same aforementioned loops. Its results reveal that the new control outperforms the pure GMC in some areas. Finally, a dynamic fouling model is developed and incorporated into the MSF dynamic process model to predict fouling at high temperature and high velocity. The proposed dynamic model considers the attachment and removal mechanisms of calcium carbonate and magnesium hydroxide with more relaxation of the assumptions. Since the MSF plant stages work as a series of heat exchangers, there is a continuous change of temperature, heat flux and salinity of the seawater. The proposed model predicts the behaviour of fouling based on the physical and thermal conditions of every single stage of the plant.
5

Design and Operation of Multistage Flash (MSF) Desalination: Advanced Control Strategies and Impact of Fouling. Design operation and control of multistage flash desalination processes: dynamic modelling of fouling, effect of non-condensable gases on venting system design and implementation of GMC and fuzzy control

Alsadaie, Salih M.M. January 2017 (has links)
The rapid increase in the demand on fresh water due the increase in the world population and scarcity of natural water puts more stress on the desalination industrial sector to install more desalination plants around the world. Among these desalination plants, multistage flash desalination process (MSF) is considered to be the most reliable technique of producing potable water from saline water. In recent years, however, the MSF process is confronting many problems to cut off the cost and increase its performance. Among these problems are the non-condensable gases (NCGs) and the accumulation of fouling which they work as heat insulation materials. As a result, the MSF pumps and the heat transfer equipment are overdesigned and consequently increase the capital cost and decrease the performance of the plants. Moreover, improved process control is a cost effective approach to energy conservation and increased process profitability. Thus, this study is motivated by the real absence of detailed kinetic fouling model and implementation of advance process control (APC). To accomplish the above tasks, commercial modelling tools can be utilized to model and simulate MSF process taking into account the NCGs and fouling effect, and optimum control strategy. In this research, gPROMS (general PROcess Modeling System) model builder has been used to develop the MSF process model. First, a dynamic mathematical model of MSF is developed based on the basic laws of mass balance, energy balance and heat transfer. Physical and thermodynamic properties of brine, distillate and water vapour are included to support the model. The model simulation results are validated against actual plant data published in the literature and good agreement with these data is obtained. Second, the design of venting system in MSF plant and the effect of NCGs on the overall heat transfer coefficient (OHTC) are studied. The release rate of NCGs is studied using Henry’s law and the locations of venting points are optimised. The results reveal that high concentration of NCGs heavily affects the OHTC. Furthermore, advance control strategy namely: generic model control (GMC) is designed and introduced to the MSF process to control and track the set points of the two most important variables in the MSF plant; namely the Top Brine Temperature (TBT) which is the output temperature of the brine heater and the Brine Level (BL) in the last stage. The results are compared to conventional Proportional Integral Derivative Controller (PID) and show that GMC controller provides better performance over conventional PID controller to handle a nonlinear system. In addition, a new control strategy called hybrid Fuzzy-GMC is developed and implemented to control the same aforementioned loops. Its results reveal that the new control outperforms the pure GMC in some areas. Finally, a dynamic fouling model is developed and incorporated into the MSF dynamic process model to predict fouling at high temperature and high velocity. The proposed dynamic model considers the attachment and removal mechanisms of calcium carbonate and magnesium hydroxide with more relaxation of the assumptions. Since the MSF plant stages work as a series of heat exchangers, there is a continuous change of temperature, heat flux and salinity of the seawater. The proposed model predicts the behaviour of fouling based on the physical and thermal conditions of every single stage of the plant.

Page generated in 0.0715 seconds