Spelling suggestions: "subject:"fractional flow reserve"" "subject:"tractional flow reserve""
1 |
Dynamic fractional flow reserve measurement: potential implications for dynamic first-pass myocardial perfusion imagingBarmby, D., Davies, A., Gislason-Lee, Amber J., Sivananthan, M. January 2015 (has links)
No
|
2 |
Circulation coronaire : Principes et méthodes de mesure invasive du flux coronaire segmentaire en pratique clinique. / Coronary circulation : Principles and methods of invasive coronary flow measurements in clinical practice.Adjedj, Julien 29 November 2017 (has links)
La circulation artérielle coronaire est un système complexe dont les méthodes de mesures invasivespermettent une évaluation en pratique clinique.Matériels et méthodes Nous développons, dans deux revues, les principes et méthodes des différentes techniques invasivesde mesure du flux coronaire en pratique clinique. Puis nous étudions l’impact clinique de l’utilisationde la Fractional Flow Reserve (FFR) dans l’évaluation des sténoses coronaires intermédiaires, lesmoyens pharmacologiques pour mesurer la FFR et sa corrélation avec l’évaluation angiographique enfonction des facteurs de risque cardiovasculaires. Enfin, nous décrivons les principes et méthodesd’une technique de mesure du flux coronaire segmentaire permettant d’obtenir la FFR, le flux et lesrésistances absolues avec un microcathéter de perfusion qui, sur un principe de thermodilutionpermet d’évaluer distinctement la macro et la microcirculation coronaire.Résultats Nous recommandons une valeur seuil de FFR de 0,80 pour guider la revascularisation car le nombred’événements cardiovasculaires et la mortalité sont spontanément supérieurs chez les patients avecune FFR <0,80 comparativement à une FFR ≥0,80 (9,4 vs. 4,8%, P=0,06 et 7,5 vs. 3,2%, P=0,06;respectivement). Nous avons étudié différents agents hyperémiants permettant de mesurer la FFR:l’adénosine (100 μg à 200 μg) permettant d’obtenir une hyperémie maximale, et le produit decontraste permettant d’atteindre 65% de cette hyperémie maximale. La mesure de la FFR avec duproduit de contraste permet de meilleures performances diagnostiques que les indices de reposcomparé à la FFR sous adénosine. Nous avons établi que la corrélation entre la FFR et le degré desténose angiographique est faible et inversement proportionnel au nombre de facteurs de risquecardiovasculaires, particulièrement chez les patients diabétiques. Enfin, nous avons décrit dans troisétudes, le principe de thermodilution coronaire et la méthode de mesures du flux coronaire et desrésistances microvasculaires avec un microcathéter de perfusion intracoronaire spécifique. Nousavons montré que cette technique est précise (R=0,98), qu’elle induit une hyperémie maximale etlocale sans agent hyperémiant et quelle est reproductible chez l’homme (R=0,91).Conclusion La compréhension de la circulation coronaire et l’application chez l’homme des techniques demesure du flux coronaire segmentaire sont essentielles tant en pratique clinique courante qu’enrecherche. / Coronary circulation is complex and highly regulated while invasive coronary flow measurements techniques allow the assessment of coronary physiology in clinical practice. Material et methods We describe in two reviews the principles and methods of different invasive coronary flowmeasurements techniques in clinical practice. We study the clinical impact of fractional flow reserve(FFR) in intermediate coronary stenosis, the hyperemic agents and dosage to measure FFR and FFRcorrelation with angiographic indices according to risk factors accumulation. Finally, we describe the principle and method of coronary flow and microvascular resistances measurements with a dedicated infusion microcatheter for coronary thermodilution to obtain assessment of macro and microvascular components of coronary circulation. Results We recommend the FFR cut off value of 0.80 to guide revascularization based on our study showing higher myocardial infarction and death rate in patients treated with medical therapy and FFR<0.80compared to those with FFR>0.80, respectively 9.4 versus 4.8%, P=0.06 and 7,5 versus 3,2%, P=0.06. We studied different hyperemic agents and dosages and showed that intracoronary adenosine at 100μg to 200 μg induce maximal hyperemia while contrast medium induce 65% of maximal hyperemia. Therefore, FFR measurements with contrast medium is feasible and has better accuracy than restindices compared to FFR. We establish the weak correlation between FFR and angiographic indicesand weakens correlation as risk factors accumulates, especially in diabetic patients. Finally, we described in three studies the method of absolute coronary flow and microvascular resistancesmeasurements based on thermodilution principle with a dedicated infusion catheter. We showed anaccurate measurement with this technique (R=0.98), which induces maximal hyperemia without theneed of hyperemic agent with reproducible measurements in humans (R=0,91).Conclusion The use of invasive coronary flow measurements to study the coronary circulation is essential inclinical practice and in research.
|
3 |
Diagnostic Accuracy of Pressure-Drop Coefficient (CDP) for Functional Assessment of Coronary Artery Disease using Multicenter International ILIAS Registry DataManegaonkar, Shreyash 31 May 2023 (has links)
No description available.
|
4 |
Influence of Serial Coronary Stenoses on Diagnostic Parameters: An <i>In-vitro</i> Study with Numerical ValidationD Souza, Gavin A. 18 June 2014 (has links)
No description available.
|
5 |
Diagnosis of Coronary Artery Disease Using Pressure Drop CoefficientKolli, Kranthi Kumar January 2014 (has links)
No description available.
|
6 |
Improved Diagnostics of Coronary Stenoses with Lesion Flow Coefficient Using GuidewiresSinha Roy, Abhijit 08 October 2007 (has links)
No description available.
|
7 |
Effect of coronary collateral flow on diagnostic parameters: An In vitro studyPeelukhana, Srikara Vishwanath January 2009 (has links)
No description available.
|
8 |
Comparison of 5-Year Clinical Outcomes between Pressure Drop Coefficient and Fractional Flow Reserve in Patients with Coronary Artery DiseaseRamadurai, Sruthi 15 June 2020 (has links)
No description available.
|
9 |
Nonhyperemic Pressure Ratios Versus Fractional Flow Reserve: What to Do With Discordant Results?Paul, Timir K., Seto, Arnold H., White, Christopher J. 15 September 2020 (has links)
No description available.
|
10 |
Fractional Flow Reserve Using Computed Tomography for Assessing Coronary Artery Disease: A Meta-AnalysisPanchal, Hemang B., Veeranki, Sreenivas P., Bhatheja, Samit, Barry, Neil, Mahmud, Ehtisham, Budoff, Matthew, Lavine, Steven J., Mamudu, Hadii M., Paul, Timir K. 01 January 2016 (has links)
Aims: Noninvasive fractional flow reserve (FFR) measurement with computed tomography (FFRCT) is a newly described method for assessing functional significance of coronary disease. The objective of this metaanalysis is to determine the diagnostic performance of FFRCTin the assessment of hemodynamically significant coronary artery stenosis. Methods: PubMed and the Cochrane Center Register of Controlled Trials were searched from January 2000 through February 2015. Six original studies were found comparing FFRCTto invasive FFR in evaluating hemodynamic significance of coronary lesions (1354 vessels; 812 patients). Lesions were considered hemodynamically significant if invasive FFR was 0.80 or less. FFRCTused the same cutoff as invasive FFR to be considered as a positive test. Sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratio were calculated. Results: One-third of the lesions (n=443) were hemodynamically significant. The pooled per-vessel analysis showed that the sensitivity, specificity, negative and positive likelihood ratios, and diagnostic odds ratio of FFRCTto diagnose hemodynamically significant coronary disease were 0.84 [95% confidence interval (CI):0.80-0.87], 0.76 (95% CI: 0.73-0.79), 0.22 (95% CI: 0.17-0.29), 3.48 (95% CI: 2.21-5.47), and 16.82 (95% CI: 8.20-34.49), respectively. Conclusion: The results of this meta-analysis demonstrate that FFRCTresults correlate closely with invasive coronary angiography and FFR measurement. It is a feasible noninvasive method to assess hemodynamic significance of coronary lesions in patients with stable coronary artery disease.
|
Page generated in 0.1602 seconds