• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Detection and Mitigation of Propagating Electrical Discharges Within the Gas Electron Multiplier Detectors of the CMS Muon System for the CERN HL-LHC

Starling, Elizabeth Rose 14 December 2020 (has links) (PDF)
In preparation for the High-Luminosity Large Hadron Collider (HL-LHC) at CERN, the Compact Muon Solenoid (CMS) Detector is undergoing a series of upgrades to its existing infrastructure, and is adding in several completely new subdetector systems. The first of these new systems, called GE1/1, is a series of 144 gas electron multiplier (GEM) detectors, arranged as 36 two-detector "superchambers" in each of the muon endcaps of CMS. These detectors are a subtype of micropattern gas detectors, and consist of three layers of "GEM foils", thin sheets of polyimide coated with 5 um of copper on each side and chemically etched with holes of 50 - 70 um diameter at a pitch of 140 um. These layers are stacked on top of a printed circuit board (PCB) readout and sealed within a gastight volume that is filled with Ar:CO2 70:30, and a high voltage is applied to the foils to create electric fields within the GEM detectors. When a muon enters the detector and ionizes the gas within, the ionized electrons encounter these fields and multiply in Townsend avalanches at each successive foil layer, until they are read out at the readout PCB at a gain of ~10^4. In early 2017, a demonstrator system known as the "slice test" was installed into the negative endcap. Consisting of 10 GEM detectors, the two-year-long slice test served as both a proof of concept for the GE1/1 system and an invaluable learning experience that would permanently impact not only the GE1/1 project, but future GEM systems GE2/1 and ME0 as well. During the slice test, it was observed that readout channels were being lost in the course of operation to such a degree that the operational lifetime of the system was in serious jeopardy. These losses were attributed to damage to the front-end readout ASIC (VFAT) inputs, caused propagating electrical discharges within the detectors, and a dedicated campaign to study the discharges was launched. The results of this study will be presented in this dissertation. A campaign to mitigate these discharges and their resulting damage was launched. In order to protect the sensitive VFAT from damage, several external protection circuits were proposed and thoroughly tested. The results of these tests, which are presented herein, determined that a series of resistors totaling 470 Ohms would be installed on the VFAT hybrid. When coupled with an additional 200 kOhm resistor on the HV filter, this reduced the probability of damage following a discharge from 93% to 3% As GE2/1 and ME0 are not due to be installed for another few years, more complex discharge-prevention measures can be put into place. As such, the following measures have been examined, and results will be discussed herein: A new, larger VFAT hybrid is being manufactured, whose larger surface area can accommodate more robust protection circuits than those considered and used for GE1/1. As well, double-segmented GEM foils, in which both the top and bottom of each foil is segmented into < 100 cm^2 sectors that are separated by resistors, were examined for use in the detectors. These double-segmented foils were found to introduce a cross-talk signal in the detectors that results in false signals being treated as true signals, which causes a saturation of the GEM bandwidth and results in unwanted dead time. These cross-talk signals, as well as the compromises made to reduce the cross-talk while maintaining robust discharge prevention, will be discussed. / Doctorat en Sciences / info:eu-repo/semantics/nonPublished
2

Development and Performance Study of Thick Gas Electron Multiplier (THGEM) Based Radiation Detector

Garai, Baishali January 2013 (has links) (PDF)
Radiations can be classified as either ionizing or non-ionizing according to whether it ionizes or does not ionize the medium through which they propagate. X-rays photons and gamma rays are the typical examples of ionizing radiations whereas radiowave, heat or visible light are examples of non ionizing radiations. UV photons have some features of both ionizing and non-ionizing radiation. Both ionizing and non-ionizing radiation can be harmful to living organisms and to the natural environment. Hence the detection and measurement of radiation is very important for the well being of living organisms as well as the natural environment. Not only for safety reasons, have radiation detectors found their applications in various fields including medical physics, nuclear and particle physics, astronomy and homeland security. Industrial sectors that use radiation detection include medical imaging, security and baggage scanning, the nuclear power industry and defense. Gas electron multiplier (GEM) is one of the most successful representatives of gaseous detectors used for UV photon and X-ray photon detection. Recently there is a growing demand for large area photon detectors with sensitivity reaching to the level of single photon. They are used in spectroscopy and imaging in astronomy high energy physics experiments etc. Thick GEM (THGEM) is a mechanical expansion of standard GEM. It has all the necessary requirements needed for large area detector and offers a multiplication factor that permits efficient detection of light. Hence, the development and performance study of THGEM based radiation detector is chosen as the topic of study in the present thesis. The initial part of the thesis contains simulation studies carried out for the understanding the working of the detector and the effect of various design parameters of THGEM for the above said applications. Different steps for the fabrication of THGEM and the technical challenges faced during the process are discussed. In the view of application of the fabricated THGEM for UV photon detection, cesium iodide photocathode is prepared using thin film technology and characterized. The performance of the photocathode under various operating conditions is studied in terms of its photoemission property. The effect of vacuum treatment on the photoemission property of the photocathode exposed to moist air is studied in detail. A major portion of this thesis focuses on maximizing the detection efficiency of the UV photon detector realized using the fabricated THGEM coupled with the cesium iodide photocathode. Simulations are used at different stages to interpret the experimental observations. The electron spectrum obtained from the detector under study was analyzed. The dependence of secondary effect like photon feedback on the operating parameters is also discussed. The last portion of the thesis deals with the application of THGEM as an X-ray detector. The performance is evaluated in terms of the gain and energy resolution achieved. The thesis is organized as follows: Chapter 1 is divided into two sections. Section A gives a general introduction to different types of radiation detectors found in the present day and their working principles. This is followed by discussion about gas ionization based detector and its working principle in detail. A brief literature survey of the different types of micropattern gas detectors is also given in this section. In Section B of this chapter GEM and THGEM are introduced with discussion about their working principle and areas of application. Chapter 2 deals with the simulation study of THGEM undertaken to have a clear understanding of the detector’s working. Section A of this chapter gives an overview of the simulation tools used for the present thesis in particular ANSYS and GARFIELD. Section B presents the results of the simulation study highlighting the effects of different geometrical and operating parameters on the electric field distribution in and around the THGEM aperture. The relevance of the study to the detectors performance is discussed vividly for all the cases. In Chapter 3, the details of the different steps involved in THGEM fabrication are given. Design aspects involved, fabrication of the THGEM using standard PCB technology coupled with photolithography technique are discussed in this chapter. This is followed by an elaborate description of the test setup used for all the performance study. Preface In the view of application of THGEM as a UV photon detector, cesium iodide photocathode was prepared and characterized. Chapter 4 discusses about the CsI photocathode preparation and its characterization for the above said application. Photoemission property of the photocathode was analyzed under various operating parameters. The effect of vacuum treatment on the photocathode performance is a new aspect of this thesis. Its correlation with the microstructure of the film is reported for the first time. Chapter 5 deals with the application of THGEM as a UV photon detector. The study mainly focuses on the improvement of the detection efficiency of the detector. The effect of drift parameters on the electron transfer efficiency and hence on the detection efficiency of the detector is a major contribution of this thesis. There are no literature available which discusses this aspect of a UV photon detector. The experimental study has been supported with simulation results. In addition to the study on detection efficiency, electron spectrum has also been acquired from the UV photon detector. The spectrum has been analyzed under various operating conditions. Discussions about secondary effects like photon feedback prevailing in the detector output are also present in this chapter. Chapter 6 presents the results of THGEM as an X-ray detector. The performance of the detector has been evaluated in terms of the effective gain and energy resolution achieved under different operating conditions. The gain instability with time and its uniformity across the THGEM area are also studied. The effect of drift field on the energy resolution and its correlation with ETE is a new aspect of this work. Chapter 7 summarizes the salient features of the work presented in this thesis. Also the scope of future work based on this thesis is discussed at the end of the chapter.

Page generated in 0.0832 seconds