• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do gel hemostático de cloreto de alumínio 25% na resistência de união dentinária com diferentes sistemas adesivos

Nascimento Sobrinho, Kleyver do 25 February 2016 (has links)
Submitted by Inês Marinho (bele_ballet@hotmail.com) on 2016-06-24T13:59:54Z No. of bitstreams: 1 Dissertação - Kleyver do Nascimento Sobrinho.pdf: 1970241 bytes, checksum: 9563817a411ce59d3b1fe44712e1f864 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-07-05T16:05:44Z (GMT) No. of bitstreams: 1 Dissertação - Kleyver do Nascimento Sobrinho.pdf: 1970241 bytes, checksum: 9563817a411ce59d3b1fe44712e1f864 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-07-05T16:08:27Z (GMT) No. of bitstreams: 1 Dissertação - Kleyver do Nascimento Sobrinho.pdf: 1970241 bytes, checksum: 9563817a411ce59d3b1fe44712e1f864 (MD5) / Made available in DSpace on 2016-07-05T16:08:27Z (GMT). No. of bitstreams: 1 Dissertação - Kleyver do Nascimento Sobrinho.pdf: 1970241 bytes, checksum: 9563817a411ce59d3b1fe44712e1f864 (MD5) Previous issue date: 2016-02-25 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / The aim of this study was to evaluate, through microshear bond strength test (μSBS), the influence of a hemostatic solution (Aluminum Chloride 25%) to the bond strength on dentin. Thirty-six (36) bovine incisors free of any structural defects were prepared and randomly divided into 6 test groups (n = 6): SB - adhesive system Scotchbond Multi-purpose (3M/ESPE); CS – Adhesive system Clearfil SE Bond (Kuraray); SU – adhesive system Single Bond Universal (3M/ESPE); SBC, CSC and SUC groups received application of the same adhesives systems used in SB, CS and SU, respectively, with the prior application of aluminum chloride 25% hemostatic solution. Following, a nanohybrid composite Filtek Z350 XT (3M/ ESPE) was applied to the dentin surface using silicon tubes (Tygon) in order to obtain composite resin cylinders in each specimen, a total of 18 cylinders in each group. The specimens were maintained at 37 °C for 7 days and then submitted to μSBS test. The bond strength values were statistically analyzed for normality by Shapiro-Wilk test and compared using two-way ANOVA and Tukey's test at a significance level of 0.05, which showed no statistically significant differences regarding the type of adhesive and contamination. In this sense, the use of aluminum chloride 25% did not influence significantly the performances of the adhesives used on dentin in this study. / O objetivo deste estudo foi avaliar, através do teste de microcisalhamento (μSBS), a influência de uma solução hemostática (Cloreto de Alumínio 25%) na resistência de união à dentina. Trinta e seis (36) dentes incisivos bovinos isentos de quaisquer defeitos estruturais foram preparados e divididos aleatoriamente em 6 grupos (n=6) teste: SB – Sistema adesivo ScotchBond Multi-uso (3M/ESPE); CS – Sistema adesivo Clearfil SE Bond (Kuraray); SU – Sistema adesivo Single Bond Universal (3M/ESPE); os grupos SBC, CSC e SUC receberam a aplicação dos mesmos sistemas adesivos empregados nos grupos SB, CS e SU, respectivamente, no entanto, com a aplicação prévia da solução hemostática à base de Cloreto de Alumínio 25%. Na sequência, o compósito nanohíbrido Filtek Z350 XT (3M/ESPE) foi aplicado à superfície dentinária através de tubos de silicone (Tygon) de maneira a obter cilindros do compósito resinoso em cada espécime, totalizando 18 cilindros em cada grupo. Os espécimes foram mantidos em estufa (37ºC) durante 7 dias e em seguida, submetidos ao teste mecânico. Os valores de resistência de união foram analisados estatisticamente para normalidade através do teste Shapiro-Wilk e comparados usando-se ANOVA two-way e Teste de Tukey em um nível de significância de 0.05, os quais não demonstraram diferença estatística significante em relação ao tipo de adesivo e ao tipo de contaminação. Neste sentido, o uso do Cloreto de Alumínio 25% não influenciou de maneira significativa, em dentina, o desempenho dos sistemas adesivos utilizados neste estudo.

Page generated in 0.0579 seconds