• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 11
  • 10
  • 10
  • 9
  • 8
  • 8
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do graute e da taxa de armadura no comportamento da alvenaria de blocos de concreto

Logullo, Bárbara Gonçalves [UNESP] 28 April 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-04-28Bitstream added on 2014-06-13T20:13:42Z : No. of bitstreams: 1 logullo_bg_me_ilha.pdf: 2174691 bytes, checksum: 2bff5d48b8a6abd70b07786d00f61690 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Apresenta-se neste trabalho uma investigação experimental do comportamento da alvenaria estrutural de blocos de concreto, resistência à compressão axial e módulo de elasticidade, em função do emprego de blocos de diferentes resistências, na presença de grautes de resistências variadas e também da existência ou não de armaduras, aplicadas em distintas taxas. Desse modo, são apresentados e comentados os resultados de ensaios de compressão axial em unidades, prismas de três blocos e pequenas paredes, montados com um só tipo de argamassa, mas com blocos de duas resistências distintas, designadas B1 e B2. Os elementos ensaiados são vazios e também preenchidos com grautes de duas resistências, definidas G1 e G2. Além destes, também são ensaiados prismas e paredes armadas, com taxas de armadura ñ 1, ñ 2 e ñ 3. Portanto, são realizados ensaios em prismas e paredes vazias, prismas e paredes grauteadas com as diferentes combinações de classes de bloco e graute e com a combinação de blocos, grautes e taxas de armadura. Com os resultados obtidos foi verificado que o grauteamento praticamente dobrou a resistência do prisma grauteado, e, nas paredes o acréscimo foi médio de 80%, comparado com prisma e parede vazia na área bruta, porém esse aumento não foi proporcional à relação efetiva de áreas. Os prismas grauteados apresentaram diminuição na deformação de ruptura com a utilização de grautes mais rígidos, e, o grauteamento homogeneizou o comportamento de deformabilidade da alvenaria e do bloco que a constitui, no prisma e na parede. Constatou-se, também, que as armaduras não alteraram o comportamento estrutural dos prismas e paredes, nem na sua resistência à compressão axial e nem na sua deformabilidade. / It is presented in this work an experimental investigation of the structural mansory of concrete blocks behavior, resistance to axial compression and elastic modulus, in function of the utilization of blocks of different resistances, with the presence of grout of varying resistances and the existance or not of armour, applied in distinct taxes. By this way, it's shown and commented the trials results of axial compression in units, three-block prisms and small walls, manufactured with just one type of mortar, but with blocks with two distincts resistances, called B1 and B2. The tested elements are empty and filled with grout of two resistances, defined as G1 and G2. Besides them, armoured prism and walls were tested too, with armour taxes called ñ 1, ñ 2 and ñ 3. Hence, the trials are executed in empty prisms and walls, grouted prisms and walls with the different combinations of classes of blocks and grouts and with the combination of blocks, grouts and armour taxes. With the obtained results, it was verified that the grout almost doubled the resistance of the grouted prism and, in walls there was an 80% increase, compared with empty prism and walls in brute area, although this increase was not proportional to the effective relation of areas. The grouted prisms presented a decrease in rupture deformation with the utilization of more rigid grouts, and the grout smoothed the deformability behaviour in mansory and in the block that form it, in prisms and walls. It was noticed too, that the armour do not alter the structure behavior of prisms and walls, not even in theirs resistance to axial compression force, neither to theirs deformability.
2

Influência da aderência graute/bloco cerâmico estrutural no comportamento mecânico do conjunto

Guarnieri, Leonel de Oliveira January 2017 (has links)
Atualmente, a alvenaria estrutural é utilizada em empreendimentos habitacionais de larga escala, nos quais as exigências de racionalização, controle, rapidez e custo são mais bem contemplados pelo sistema. No Brasil, existem empreendimentos de até 16 pavimentos construídos com blocos de alta resistência e alto controle tecnológico. A construção de edificações com maiores alturas exige o aumento da capacidade de absorção de esforços de compressão e tração. Para isso, são inseridas barras de aço nos vazados dos blocos e consolidadas com graute, a fim de aumentar a capacidade portante do conjunto. Entretanto, a influência da aderência graute/ bloco cerâmico no comportamento mecânico da alvenaria estrutural ainda é uma dúvida, visto que a NBR 15812 - 1 (ABNT, 2010) não especifica um valor de resistência para aderência graute/ bloco cerâmico, somente para graute/ aço. Frente a essa constatação, a presente pesquisa tem o objetivo de avaliar a influência da aderência graute/ bloco cerâmico estrutural no comportamento mecânico do conjunto, para determinar um valor de tensão de aderência que possa contribuir com a NBR 15812-1 (ABNT, 2010) Para isso, foram utilizados quatro tipos de blocos cerâmicos, com variação da geometria interna dos vazados e resistência mecânica à compressão. O graute foi padronizado em somente uma resistência, sendo essa de 30 MPa. Para desenvolvimento da pesquisa, inicialmente foi realizada a caracterização dos materiais e, posteriormente, realizados ensaios de push-out, resistência à compressão de blocos preenchidos com graute e microscopia óptica. Os resultados revelaram que a aderência graute/ bloco cerâmico estrutural é superior à resistência mecânica à tração do bloco cerâmico, e que a ruptura do conjunto ocorre primeiramente no bloco. Os resultados também constataram aumento da resistência mecânica à compressão axial nos blocos preenchidos com graute. / Currently, structural masonry is used in large-scale housing projects, in which the requirements of rationalization, control, speed and cost are better covered by the system. In Brazil there are projects of up to 16 floors built with high resistance and high technological control blocks. The construction of buildings with higher heights requires the increase of the capacity of absorption of compression and traction forces. For this, steel bars are inserted into hollow blocks which are then consolidated with grout in order to increase the load-bearing capacity of the assembly. However, the influence of ceramic block/grout adhesion in the mechanical behavior of structural masonry is still unknown since the NBR 15812-1 (ABNT, 2010) standard does not specify a resistance value for grout/ceramic block adhesion, only for grout/steel adhesion. In view of this finding, the present research has the objective of evaluating the influence of the structural ceramic block/grout adhesion on the mechanical behavior of the assembly in order to determine a value of adhesion tension that can contribute to the NBR 15812-1 (ABNT, 2010) standard For this purpose four types of ceramic blocks with a variation in the internal geometry of the hollow spaces and mechanical strength to compression were used. Grout was standardized in only one strength of 30 MPa. For development of the research, initially the characterization of the materials was performed and, subsequently, the tests of push-out and compressive strength of grout-filled blocks and light microscopy. The results showed that the grout/ceramic block adhesion is superior to the mechanical tensile strength of the ceramic block and, therefore, the rupture of the assembly will occur first in the block. The results also showed a significant increase of the mechanical resistance to axial compression in blocks filled with grout.
3

Influência da aderência graute/bloco cerâmico estrutural no comportamento mecânico do conjunto

Guarnieri, Leonel de Oliveira January 2017 (has links)
Atualmente, a alvenaria estrutural é utilizada em empreendimentos habitacionais de larga escala, nos quais as exigências de racionalização, controle, rapidez e custo são mais bem contemplados pelo sistema. No Brasil, existem empreendimentos de até 16 pavimentos construídos com blocos de alta resistência e alto controle tecnológico. A construção de edificações com maiores alturas exige o aumento da capacidade de absorção de esforços de compressão e tração. Para isso, são inseridas barras de aço nos vazados dos blocos e consolidadas com graute, a fim de aumentar a capacidade portante do conjunto. Entretanto, a influência da aderência graute/ bloco cerâmico no comportamento mecânico da alvenaria estrutural ainda é uma dúvida, visto que a NBR 15812 - 1 (ABNT, 2010) não especifica um valor de resistência para aderência graute/ bloco cerâmico, somente para graute/ aço. Frente a essa constatação, a presente pesquisa tem o objetivo de avaliar a influência da aderência graute/ bloco cerâmico estrutural no comportamento mecânico do conjunto, para determinar um valor de tensão de aderência que possa contribuir com a NBR 15812-1 (ABNT, 2010) Para isso, foram utilizados quatro tipos de blocos cerâmicos, com variação da geometria interna dos vazados e resistência mecânica à compressão. O graute foi padronizado em somente uma resistência, sendo essa de 30 MPa. Para desenvolvimento da pesquisa, inicialmente foi realizada a caracterização dos materiais e, posteriormente, realizados ensaios de push-out, resistência à compressão de blocos preenchidos com graute e microscopia óptica. Os resultados revelaram que a aderência graute/ bloco cerâmico estrutural é superior à resistência mecânica à tração do bloco cerâmico, e que a ruptura do conjunto ocorre primeiramente no bloco. Os resultados também constataram aumento da resistência mecânica à compressão axial nos blocos preenchidos com graute. / Currently, structural masonry is used in large-scale housing projects, in which the requirements of rationalization, control, speed and cost are better covered by the system. In Brazil there are projects of up to 16 floors built with high resistance and high technological control blocks. The construction of buildings with higher heights requires the increase of the capacity of absorption of compression and traction forces. For this, steel bars are inserted into hollow blocks which are then consolidated with grout in order to increase the load-bearing capacity of the assembly. However, the influence of ceramic block/grout adhesion in the mechanical behavior of structural masonry is still unknown since the NBR 15812-1 (ABNT, 2010) standard does not specify a resistance value for grout/ceramic block adhesion, only for grout/steel adhesion. In view of this finding, the present research has the objective of evaluating the influence of the structural ceramic block/grout adhesion on the mechanical behavior of the assembly in order to determine a value of adhesion tension that can contribute to the NBR 15812-1 (ABNT, 2010) standard For this purpose four types of ceramic blocks with a variation in the internal geometry of the hollow spaces and mechanical strength to compression were used. Grout was standardized in only one strength of 30 MPa. For development of the research, initially the characterization of the materials was performed and, subsequently, the tests of push-out and compressive strength of grout-filled blocks and light microscopy. The results showed that the grout/ceramic block adhesion is superior to the mechanical tensile strength of the ceramic block and, therefore, the rupture of the assembly will occur first in the block. The results also showed a significant increase of the mechanical resistance to axial compression in blocks filled with grout.
4

Influência do graute e da taxa de armadura no comportamento da alvenaria de blocos de concreto /

Logullo, Bárbara Gonçalves. January 2006 (has links)
Orientador: Jefferson Sidney Camacho / Banca: Jorge Luis Akasaki / Banca: João Bento de Hanai / Resumo: Apresenta-se neste trabalho uma investigação experimental do comportamento da alvenaria estrutural de blocos de concreto, resistência à compressão axial e módulo de elasticidade, em função do emprego de blocos de diferentes resistências, na presença de grautes de resistências variadas e também da existência ou não de armaduras, aplicadas em distintas taxas. Desse modo, são apresentados e comentados os resultados de ensaios de compressão axial em unidades, prismas de três blocos e pequenas paredes, montados com um só tipo de argamassa, mas com blocos de duas resistências distintas, designadas B1 e B2. Os elementos ensaiados são vazios e também preenchidos com grautes de duas resistências, definidas G1 e G2. Além destes, também são ensaiados prismas e paredes armadas, com taxas de armadura ñ 1, ñ 2 e ñ 3. Portanto, são realizados ensaios em prismas e paredes vazias, prismas e paredes grauteadas com as diferentes combinações de classes de bloco e graute e com a combinação de blocos, grautes e taxas de armadura. Com os resultados obtidos foi verificado que o grauteamento praticamente dobrou a resistência do prisma grauteado, e, nas paredes o acréscimo foi médio de 80%, comparado com prisma e parede vazia na área bruta, porém esse aumento não foi proporcional à relação efetiva de áreas. Os prismas grauteados apresentaram diminuição na deformação de ruptura com a utilização de grautes mais rígidos, e, o grauteamento homogeneizou o comportamento de deformabilidade da alvenaria e do bloco que a constitui, no prisma e na parede. Constatou-se, também, que as armaduras não alteraram o comportamento estrutural dos prismas e paredes, nem na sua resistência à compressão axial e nem na sua deformabilidade. / Abstract: It is presented in this work an experimental investigation of the structural mansory of concrete blocks behavior, resistance to axial compression and elastic modulus, in function of the utilization of blocks of different resistances, with the presence of grout of varying resistances and the existance or not of armour, applied in distinct taxes. By this way, it's shown and commented the trials results of axial compression in units, three-block prisms and small walls, manufactured with just one type of mortar, but with blocks with two distincts resistances, called B1 and B2. The tested elements are empty and filled with grout of two resistances, defined as G1 and G2. Besides them, armoured prism and walls were tested too, with armour taxes called ñ 1, ñ 2 and ñ 3. Hence, the trials are executed in empty prisms and walls, grouted prisms and walls with the different combinations of classes of blocks and grouts and with the combination of blocks, grouts and armour taxes. With the obtained results, it was verified that the grout almost doubled the resistance of the grouted prism and, in walls there was an 80% increase, compared with empty prism and walls in brute area, although this increase was not proportional to the effective relation of areas. The grouted prisms presented a decrease in rupture deformation with the utilization of more rigid grouts, and the grout smoothed the deformability behaviour in mansory and in the block that form it, in prisms and walls. It was noticed too, that the armour do not alter the structure behavior of prisms and walls, not even in theirs resistance to axial compression force, neither to theirs deformability. / Mestre
5

Influência da aderência graute/bloco cerâmico estrutural no comportamento mecânico do conjunto

Guarnieri, Leonel de Oliveira January 2017 (has links)
Atualmente, a alvenaria estrutural é utilizada em empreendimentos habitacionais de larga escala, nos quais as exigências de racionalização, controle, rapidez e custo são mais bem contemplados pelo sistema. No Brasil, existem empreendimentos de até 16 pavimentos construídos com blocos de alta resistência e alto controle tecnológico. A construção de edificações com maiores alturas exige o aumento da capacidade de absorção de esforços de compressão e tração. Para isso, são inseridas barras de aço nos vazados dos blocos e consolidadas com graute, a fim de aumentar a capacidade portante do conjunto. Entretanto, a influência da aderência graute/ bloco cerâmico no comportamento mecânico da alvenaria estrutural ainda é uma dúvida, visto que a NBR 15812 - 1 (ABNT, 2010) não especifica um valor de resistência para aderência graute/ bloco cerâmico, somente para graute/ aço. Frente a essa constatação, a presente pesquisa tem o objetivo de avaliar a influência da aderência graute/ bloco cerâmico estrutural no comportamento mecânico do conjunto, para determinar um valor de tensão de aderência que possa contribuir com a NBR 15812-1 (ABNT, 2010) Para isso, foram utilizados quatro tipos de blocos cerâmicos, com variação da geometria interna dos vazados e resistência mecânica à compressão. O graute foi padronizado em somente uma resistência, sendo essa de 30 MPa. Para desenvolvimento da pesquisa, inicialmente foi realizada a caracterização dos materiais e, posteriormente, realizados ensaios de push-out, resistência à compressão de blocos preenchidos com graute e microscopia óptica. Os resultados revelaram que a aderência graute/ bloco cerâmico estrutural é superior à resistência mecânica à tração do bloco cerâmico, e que a ruptura do conjunto ocorre primeiramente no bloco. Os resultados também constataram aumento da resistência mecânica à compressão axial nos blocos preenchidos com graute. / Currently, structural masonry is used in large-scale housing projects, in which the requirements of rationalization, control, speed and cost are better covered by the system. In Brazil there are projects of up to 16 floors built with high resistance and high technological control blocks. The construction of buildings with higher heights requires the increase of the capacity of absorption of compression and traction forces. For this, steel bars are inserted into hollow blocks which are then consolidated with grout in order to increase the load-bearing capacity of the assembly. However, the influence of ceramic block/grout adhesion in the mechanical behavior of structural masonry is still unknown since the NBR 15812-1 (ABNT, 2010) standard does not specify a resistance value for grout/ceramic block adhesion, only for grout/steel adhesion. In view of this finding, the present research has the objective of evaluating the influence of the structural ceramic block/grout adhesion on the mechanical behavior of the assembly in order to determine a value of adhesion tension that can contribute to the NBR 15812-1 (ABNT, 2010) standard For this purpose four types of ceramic blocks with a variation in the internal geometry of the hollow spaces and mechanical strength to compression were used. Grout was standardized in only one strength of 30 MPa. For development of the research, initially the characterization of the materials was performed and, subsequently, the tests of push-out and compressive strength of grout-filled blocks and light microscopy. The results showed that the grout/ceramic block adhesion is superior to the mechanical tensile strength of the ceramic block and, therefore, the rupture of the assembly will occur first in the block. The results also showed a significant increase of the mechanical resistance to axial compression in blocks filled with grout.
6

ANÁLISE DO COMPORTAMENTO DE PRISMAS GRAUTEADOS DE ALVENARIA ESTRUTURAL CERÂMICA / ANALYSIS OF THE BEHAVIOR OF GROUTED CLAY PRISMS FOR STRUCTURAL MASONRY

Grohmann, Leandro Zampieri 24 February 2006 (has links)
The main purpose of this thesis is to evaluate the behavior of clay prisms grouted, partially grouted and ungrouted under compression loads in order to analyze the influence and performance of the grout, as well as to seek how to optimize its applicability. For that, testing was done with different grouts and grouting ratios. The testing was done in 120 prisms under simple axial compression load, where sets of prisms had two different types of mortar (A1 and A2), three different grouts (G1, G2 e G3) and four different ratios of grouted cavities (0%, 33%, 66% e 100%). For this testing, all the materials and components were previously characterized. Based on experimental data, the analysis of the results was done taking into account the different sets of prisms grouping them according to their mortar, grout and grouting ratio. The variance analysis for the sample was done in order to prove the existence of significant differences among the various group combinations. It was also performed a comparison among the data found and results gathered by other researchers. Another investigation was done regarding the fracture behavior of prisms and the influence of interactions among block, mortar and grout was observed. Through the analysis of the results, some of the conclusions regarding the behavior of prisms were: the importance of the mortar s strength for the compression strength of the prisms; the increase in the strength of the grout does not indicate a significant increase in the prisms strength; the significant increase in the prisms strength is noticed only when the totality of the prisms cavities are grouted. Overall, the use of masonry walls with partially grouted cavities is efficient if properly used. For that, the types of grout and mortar must be suitable to and in accordance with the mechanical behavior of the blocks used. / Este trabalho tem como objetivo principal avaliar o comportamento de prismas de blocos cerâmicos grauteados, parcialmente grauteados e não-grauteados sob a ação de cargas de compressão para que se possa analisar a influência e o desempenho do graute e buscar sua otimização. Para tanto, foram realizados ensaios experimentais de prismas com diferentes tipos de grautes e porcentagens de grauteamento. O método de pesquisa compreendeu o ensaio de compressão axial simples de 120 prismas contrafiados de blocos cerâmicos com a utilização de dois tipos de argamassa (A1 e A2), três tipos de grautes (G1, G2 e G3) e quatro diferentes porcentagens de células grauteadas (0%, 33%, 66% e 100%), onde todos os materiais e componentes empregados foram previamente caracterizados. Com base nos dados experimentais foi realizada uma análise dos resultados obtidos, por tipo de argamassa, tipo de graute e porcentagem de grauteamento utilizados. Para comprovar a existência de diferenças significativas entre as várias combinações de prismas ensaiados, foi feita a análise de variância da amostra ensaiada. De posse destes resultados, foram feitas comparações com resultados obtidos por outros autores. Também observou-se, neste trabalho, os modos de ruptura dos prismas e foi constatada a influência das interações entre bloco, argamassa e graute neste comportamento. Através da análise dos resultados pôde-se chegar a conclusões sobre o comportamento dos prismas, como: a importância da resistência da argamassa na resistência à compressão dos prismas; um aumento não significativo de resistência dos prismas ao aumentar a resistência do graute; e um ganho efetivo de resistência dos prismas somente ao terem a totalidade de suas células grauteadas. De modo geral, conclui-se que a utilização do grauteamento parcial em painéis de alvenaria é eficiente desde que seja utilizado de forma adequada, havendo compatibilização da dosagem de traços de grautes e argamassas com as características mecânicas dos blocos utilizados.
7

RESISTÊNCIA À COMPRESSÃO DE PRISMAS PREENCHIDOS COM ARGAMASSA / GRAUTE / PRISMS MECHANICAL EVALUATION FILLED WITH MORTAR / GROUT THE COMPRESSION

Marco, Carlos Eduardo Giacomini de 10 March 2016 (has links)
This work has as main objective to analyze the mechanical behavior of prisms run with ceramic bricks and filled with mortar or grout, checking their influence when subjected to centric compression. An experimental program consists of four different types of prisms was developed. They were used for making the prisms blocks of three different Manufacturers. The ceramics were randomly named as Manufacturer 1 Manufacturer 2 and Manufacturer 3, manufacturers have provided the following resistance of structural blocks: Manufacturer 1 - fbk (A) 6 MPa, Manufacturer 2 - fbk (E) 7 MPa and fbk (C) 15 MPa Manufacturer 3 - FBK (B) and 6 MPa FBK (D) 15 MPa.The prisms were molded with industrialized mortar. Each prism type with its respective resistors blocks were molded as follows: hollow prism, prisms filled with grout (the larger castings), the same used in the settlement, and prisms filled with grout, totaling 320 prisms, which were subjected to tests to simple axial compression. The results were analyzed statistically by the Tukey test at 5% significance level. It was concluded that the grout used not added significant increase in resistance to the prisms, the study can not say whether it is possible or not to replace the grout by mortar, to fill the cast, as well as adequate strength of the mortar used in filling It should be further studied. / Este trabalho tem como objetivo principal analisar o comportamento mecânico de prismas executados com blocos cerâmicos e preenchidos com argamassa ou graute, verificando a sua influência quando submetidos à compressão centrada. Foi desenvolvido um programa experimental composto por quatro diferentes tipos de prismas. Foram utilizados para confecção dos prismas blocos de três diferentes cerâmicas. As cerâmicas foram nomeadas aleatoriamente como Fabricante 1, Fabricante 2 e Fabricante 3. Os fabricantes forneceram as seguintes resistências de Blocos Estruturais: Fabricante 1 fbk(A) 6 MPa, Fabricante 2 fbk(E) 7 MPa e fbk(C) 15 MPa, Fabricante 3 fbk(B) 6 MPa e fbk(D) 15 MPa. Os prismas foram moldados com argamassa industrializada. Cada tipo de prisma, com suas respectivas resistências de blocos, foi moldado da seguinte forma: prismas ocos, prismas preenchidos com argamassa (nos vazados maiores), a mesma utilizada no assentamento; e prismas preenchidos com graute, totalizando 320 prismas, os quais foram submetidos a ensaios à compressão axial simples.Os resultados foram analisados estatisticamente através do Teste de Tukey com nível de significância de 5%. Concluiu-se que o graute utilizado não agregou significativo acréscimo de resistência aos prismas. Pelo estudo realizado não se pode afirmar se é possível ou não substituir o graute pela argamassa, no preenchimento dos vazados, assim como a resistência adequada da argamassa com uso no preenchimento deve ser novamente estudada.
8

Especificação, execução e controle de alvenaria estrutural em blocos cerâmicos de acordo com a NBR 15812

Soares, Márcia Maria Melo 02 December 2011 (has links)
Made available in DSpace on 2016-06-02T20:09:15Z (GMT). No. of bitstreams: 1 4131.pdf: 5121698 bytes, checksum: 60d237f10f43ef96eeb3676d4f0f3c7b (MD5) Previous issue date: 2011-12-02 / This dissertation refers to the specification, execution and build s control in masonry structural of ceramic blocks, according to the current standard ABNT NBR 15812 (ABNT, 2010). The specification was evaluated by testing the compressive strength of mortar, blocks, grout, prisms and walls, which are materials constituted of various combinations, in order to define their efficiency factors. The relationship between the compressive strength in hollow blocks and prism and in blocks filled up with mortar or grout has been established, showing, as result, loss of strength in prism when the mortar was dosed with excess water. Also, there was a variation in resistance of the filled prism when the executive procedure was improved by the implementation of re-densification. Finally, It was explained the execution and build s control in masonry structural of ceramic blocks, according to the existing literature and recommendations of NBR 15812 (ABNT, 2010). / Este trabalho trata da especificação, execução e controle de obras em alvenaria estrutural de blocos cerâmicos conforme a NBR 15812 (ABNT, 2010). Na etapa de especificação foi avaliada, através de ensaios, a resistência à compressão de argamassas, blocos, grautes, prismas e paredes, constituídos por diversas combinações, concluindo, para os materiais estudados os seus respectivos fatores de eficiência. Foram estabelecidas relações de resistência à compressão de blocos e prismas ocos e cheios por argamassa ou graute. Foi verificada a perda na resistência de prismas quando a argamassa é dosada com excesso de água. Também se verificou a variação da resistência de prisma cheio quando melhorado o procedimento executivo através da execução de re-adensamento. Por fim, foram sistematizadas a execução e controle de obras de alvenaria estrutural de blocos cerâmicos de acordo com a bibliografia existente e recomendações da NBR 15812 (ABNT, 2010).
9

Estudo da interface bloco/graute em elementos de alvenaria estrutural / Study of the block/grout interface in concrete and clay block masonry structures

Soto Izquierdo, Orieta 08 April 2015 (has links)
A construção de edifícios em alvenaria estrutural tem evoluído de maneira significativa no Brasil. Os edifícios têm se tornado cada vez mais altos, atingindo a marca de 20 pavimentos. Quanto mais altos os edifícios, maiores se tornam os níveis de compressão provenientes dos carregamentos verticais e a sua composição com as ações devidas ao vento e ao desaprumo, obrigando a um maior emprego da alvenaria estrutural armada. A aderência bloco/graute como fator limitante à capacidade do conjunto armadura/graute/bloco na absorção da compressão e tração simples ou da tração oriunda da flexão não é especificada nas normas tanto nacionais como internacionais. Este trabalho tem como objetivo principal estudar o comportamento da interface bloco/graute, tanto para blocos de concreto como cerâmicos e com a presença ou não de armadura, submetidos a solicitações que provocam tração e compressão. Recursos experimentais e numéricos foram realizados para o desenvolvimento da presente pesquisa. Foram feitos ensaios de caracterização dos materiais, dos componentes e da alvenaria, além de ensaios de \"push-out\" (empurramento) para determinar a resistência de aderência na interface graute/bloco e ensaios de \"pull-out\" (arrancamento) considerando-se a presença de barras de armadura para o estudo do comportamento do conjunto graute/bloco/armadura utilizados. Posteriormente foram realizadas modelagens computacionais no programa DIANA, que é baseado no método dos elementos finitos, para prever o comportamento estrutural dos modelos. A partir dos resultados experimentais e numéricos pôde-se concluir que existe uma boa aderência entre as paredes dos blocos de concreto e o graute, suficiente para evitar o escorregamento, sendo possível mobilizar toda a resistência de tração das barras de armadura de diâmetros usuais, desde que devidamente ancoradas. Já com os blocos cerâmicos observa-se uma menor aderência entre as paredes dos blocos e o graute, podendo ocorrer o escorregamento do material de enchimento, antes que a armadura alcance sua tensão de escoamento. O graute de maior resistência à compressão e menor fator água cimento (graute G30) apresentou maior resistência de aderência em relação ao graute mais fraco (graute G14) e de maior fator água/cimento. Quanto aos limites estabelecidos para a tensão de escoamento das armaduras, observa-se que, no caso de blocos de concreto, não deve haver restrição. Em contraposição, quanto aos blocos cerâmicos, o problema é mais complexo, cabendo a realização de mais ensaios para a confirmação de limites, com a variação de blocos e grautes. Os resultados do estudo paramétrico apontam limites que devem ser adotados no caso de diâmetro superior a 10 mm. De maneira simplificada, como ponto para futuras verificações pode-se propor: 75% para Ø 12,5 mm, 50% para Ø 16 mm e 25% para Ø 20 mm. As análises numéricas realizadas nos modelos ensaiados a push-out e pull-out representaram adequadamente o comportamentos observado em laboratório, permitindo a realização da análise paramétrica. / The construction of structural masonry buildings has evolved significantly in Brazil. The buildings have become ever higher, reaching the level of 20 floors. Higher buildings lead to lager compression levels, coming from the vertical loads combined to the horizontal actions due to wind and lack of verticality, obliging a greater use of reinforced structural masonry. The block/grout adherence is not specified in both national and international standards. This work aims to study the behavior of the block/grout interface, for both concrete and clay blocks, with and without reinforcement, submitted to tensile and compressive forces. Experimental and numerical resources were used to development of this study. The experimental program studied the masonry behavior using push-out specimens to determine the bond strength between the grout and the concrete unit, and pull-out specimens to study the behavior of the interface of the grout/block/reinforcement. Computational modelling was carried out using the FEM software Diana, which has a library with constitutive models suitable for civil engineering application, to complete the study and understand the structural behavior of the block/grout interface. The experimental results showed that there is a good bond between the concrete blocks internal faces and the grout, enough to prevent infill-slippage, and that the whole tensile strength of the usual reinforcement rebars is achieved provided they are properly anchored. Nevertheless, for clay blocks there is a low bond between the clay blocks internal faces and the grout, allowing the infill-slippage before the reinforcement bars reach their yield stress. The higher strength grout with lower water/cement ratio (grout G30) presented higher bond strength compared to the lower strength grout and higher water/cement ratio (grout G14). In the case of concrete blocks there should be no restriction limits on the yield stress of reinforcement, in a practical sense and considering other prescribed limits. In contradiction, in the case of clay blocks, additional tests should be carried out for establishing limits, with varying blocks and grouts. The parametric analysis indicates limits that should be adopted for a diameter larger than 10 mm. The authors of this research suggest 75% for Ø 12.5 mm, 50% for Ø 16 mm and 25% for Ø 20 mm as a reference point for future investigations. The numerical analysis showed that the computer models of the push-out and pull-out specimens represented adequately the behavior of the physical models, and thus can be used in parametric analysis.
10

Estudo da interface bloco/graute em elementos de alvenaria estrutural / Study of the block/grout interface in concrete and clay block masonry structures

Orieta Soto Izquierdo 08 April 2015 (has links)
A construção de edifícios em alvenaria estrutural tem evoluído de maneira significativa no Brasil. Os edifícios têm se tornado cada vez mais altos, atingindo a marca de 20 pavimentos. Quanto mais altos os edifícios, maiores se tornam os níveis de compressão provenientes dos carregamentos verticais e a sua composição com as ações devidas ao vento e ao desaprumo, obrigando a um maior emprego da alvenaria estrutural armada. A aderência bloco/graute como fator limitante à capacidade do conjunto armadura/graute/bloco na absorção da compressão e tração simples ou da tração oriunda da flexão não é especificada nas normas tanto nacionais como internacionais. Este trabalho tem como objetivo principal estudar o comportamento da interface bloco/graute, tanto para blocos de concreto como cerâmicos e com a presença ou não de armadura, submetidos a solicitações que provocam tração e compressão. Recursos experimentais e numéricos foram realizados para o desenvolvimento da presente pesquisa. Foram feitos ensaios de caracterização dos materiais, dos componentes e da alvenaria, além de ensaios de \"push-out\" (empurramento) para determinar a resistência de aderência na interface graute/bloco e ensaios de \"pull-out\" (arrancamento) considerando-se a presença de barras de armadura para o estudo do comportamento do conjunto graute/bloco/armadura utilizados. Posteriormente foram realizadas modelagens computacionais no programa DIANA, que é baseado no método dos elementos finitos, para prever o comportamento estrutural dos modelos. A partir dos resultados experimentais e numéricos pôde-se concluir que existe uma boa aderência entre as paredes dos blocos de concreto e o graute, suficiente para evitar o escorregamento, sendo possível mobilizar toda a resistência de tração das barras de armadura de diâmetros usuais, desde que devidamente ancoradas. Já com os blocos cerâmicos observa-se uma menor aderência entre as paredes dos blocos e o graute, podendo ocorrer o escorregamento do material de enchimento, antes que a armadura alcance sua tensão de escoamento. O graute de maior resistência à compressão e menor fator água cimento (graute G30) apresentou maior resistência de aderência em relação ao graute mais fraco (graute G14) e de maior fator água/cimento. Quanto aos limites estabelecidos para a tensão de escoamento das armaduras, observa-se que, no caso de blocos de concreto, não deve haver restrição. Em contraposição, quanto aos blocos cerâmicos, o problema é mais complexo, cabendo a realização de mais ensaios para a confirmação de limites, com a variação de blocos e grautes. Os resultados do estudo paramétrico apontam limites que devem ser adotados no caso de diâmetro superior a 10 mm. De maneira simplificada, como ponto para futuras verificações pode-se propor: 75% para Ø 12,5 mm, 50% para Ø 16 mm e 25% para Ø 20 mm. As análises numéricas realizadas nos modelos ensaiados a push-out e pull-out representaram adequadamente o comportamentos observado em laboratório, permitindo a realização da análise paramétrica. / The construction of structural masonry buildings has evolved significantly in Brazil. The buildings have become ever higher, reaching the level of 20 floors. Higher buildings lead to lager compression levels, coming from the vertical loads combined to the horizontal actions due to wind and lack of verticality, obliging a greater use of reinforced structural masonry. The block/grout adherence is not specified in both national and international standards. This work aims to study the behavior of the block/grout interface, for both concrete and clay blocks, with and without reinforcement, submitted to tensile and compressive forces. Experimental and numerical resources were used to development of this study. The experimental program studied the masonry behavior using push-out specimens to determine the bond strength between the grout and the concrete unit, and pull-out specimens to study the behavior of the interface of the grout/block/reinforcement. Computational modelling was carried out using the FEM software Diana, which has a library with constitutive models suitable for civil engineering application, to complete the study and understand the structural behavior of the block/grout interface. The experimental results showed that there is a good bond between the concrete blocks internal faces and the grout, enough to prevent infill-slippage, and that the whole tensile strength of the usual reinforcement rebars is achieved provided they are properly anchored. Nevertheless, for clay blocks there is a low bond between the clay blocks internal faces and the grout, allowing the infill-slippage before the reinforcement bars reach their yield stress. The higher strength grout with lower water/cement ratio (grout G30) presented higher bond strength compared to the lower strength grout and higher water/cement ratio (grout G14). In the case of concrete blocks there should be no restriction limits on the yield stress of reinforcement, in a practical sense and considering other prescribed limits. In contradiction, in the case of clay blocks, additional tests should be carried out for establishing limits, with varying blocks and grouts. The parametric analysis indicates limits that should be adopted for a diameter larger than 10 mm. The authors of this research suggest 75% for Ø 12.5 mm, 50% for Ø 16 mm and 25% for Ø 20 mm as a reference point for future investigations. The numerical analysis showed that the computer models of the push-out and pull-out specimens represented adequately the behavior of the physical models, and thus can be used in parametric analysis.

Page generated in 0.0208 seconds