Spelling suggestions: "subject:"2around source heat pump systems."" "subject:"4wsground source heat pump systems.""
1 |
Simulation and design of hybrid geothermal heat pump systemsChiasson, Andrew D. January 2007 (has links)
Thesis (Ph.D.)--University of Wyoming, 2007. / Title from PDF title page (viewed on June 17, 2009). Includes bibliographical references (p. 167-178).
|
2 |
Ground source heat pump system models in an integrated building and ground energy simulation environmentGarber, Denis January 2014 (has links)
No description available.
|
3 |
Simulation of a vertical ground-coupled heat pump system with optimal ground loop designAdivi, Krishna C. January 1900 (has links)
Thesis (M.S.)--West Virginia University, 2003. / Title from document title page. Document formatted into pages; contains ix, 92 p. : ill. (some col.). Includes abstract. Includes bibliographical references (p. 72-75).
|
4 |
Finite element modelling of thermal piles and wallsRui, Yi January 2015 (has links)
No description available.
|
5 |
Computer modelling and simulation of geothermal heat pump and ground-coupled liquid desiccant air conditioning systems in sub-tropicalregionsLee, Chun-kwong., 李振光. January 2008 (has links)
published_or_final_version / Mechanical Engineering / Doctoral / Doctor of Philosophy
|
6 |
Computer modelling and simulation of geothermal heat pump and ground-coupled liquid desiccant air conditioning systems in sub-tropical regionsLee, Chun-kwong. January 2008 (has links)
Thesis (Ph. D.)--University of Hong Kong, 2009. / Includes bibliographical references (leaves 177-192) Also available in print.
|
7 |
Effects of ground-coupled heat pumps on hydrogeologic systems : Ball State University / Effects of ground coupled heat pumps on hydrogeologic systemsDunn, Marsha E. 20 July 2013 (has links)
In 2009 Ball State University began construction on the nation’s largest ground-source geothermal system in attempt to reduce its environmental impacts and heating/cooling expenses. Since late November 2011, half of the geothermal system has been operational. Due to only partial geothermal use and a warm winter in 2011, thermal increases can be seen throughout the Phase 1 fields. After system initiation in 2011, an average temperature increase of 4.33°C has been observed in the bottom 80-120+ meters in the middle of the South Field, while no increase was found in the southern-edge well of the North Field. To evaluate thermal increases, hydraulic characteristics were gathered including groundwater flow direction, hydraulic gradients and hydraulic conductivities. Varying temperatures throughout the area may affect the groundwater geochemistry. Geochemical results indicate a calcium-bicarbonate facies. / Geothermal well field construction -- Study site -- Methods -- Results -- Discussion. / Department of Geological Sciences
|
8 |
THERMAL ENERGY STORAGE INTEGRATED GROUND SOURCE HEAT PUMP SYSTEM FOR DE-CARBONIZATIONLiang Shi (13269246) 30 April 2023 (has links)
<p>To reduce greenhouse gas emissions, shifting the energy sources used in buildings, transportation, industry, etc., from fossil fuels to clean electricity is a trend. The increasing electricity demand stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Residential and commercial buildings' space heating/cooling system consumes considerable electricity. Integrating thermal energy storage (TES) in building heating/cooling systems can mitigate the challenge of electric grids. Applying TES to existing air-source heat pump (ASHP) systems is the most studied for residential buildings. However, the high-quality thermal energy requirement for charging the TES tank results in low thermal performance of the ASHP system. Moreover, the failure of ASHP in cold climates requires a supplemental electric heater that significantly reduces the system efficiency and may lead to a higher annual peak for the grids.</p>
<p>This study proposes integrating TES with ground-source heat pump (GSHP) systems as a more effective solution for building decarbonization due to the high efficiency of renewable-energy-based GSHPs year-round. This study focuses on proving the effectiveness of TES-integrated GSHPs for building decarbonization. A dual-source heat pump (DSHP) with a hybrid TES and ground heat exchanger (GHE) named dual-purpose underground thermal battery (DPUTB) is investigated. The study uses modeling and experiments to verify the system's energy efficiency, decarbonization potential, and demand response capability. The modeling process involves developing various models, from component-level to system-level, and investigating advanced control strategies. A first-of-this-kind dynamic model of the DPUTB is developed to enable high-resolution system simulation for the GSHP system. The simulation is conducted using Modelica with rule-based control (RBC). A model predictive control (MPC) is also developed based on dynamic building envelope and heating, ventilation, and air conditioning (HVAC) system models. A cutting-edge co-simulation testbed integrates Modelica physical models with a MATLAB MPC controller model for advanced control evaluation. A prototype system of the DPUTB+DSHP is tested in a flexible research platform (FRP) at Oak Ridge National Laboratory (ORNL), which allows for component and system-level testing and remote automation controls. </p>
<p>The study highlights the importance of proper insulation in the performance of the DPUTB, which consists of a TES tank enclosed by an outer tank functioning as a GHE. With appropriate insulation, a full-size DPUTB can store 1-ton cooling (3.5 kW) for four hours after eight hours of charging. Simulation results suggest that decoupling the TES with the GHE could reduce energy consumption by 27%. System-level simulations confirm that the DSHP+DPUTB system, with a customized RBC, outperforms the conventional ASHP. The proposed system can reduce the annual HVAC electricity cost by up to 50% while saving 45% on electricity consumption. In the Northern areas of the United States, the annual peak load of the HVAC system can be reduced by 60%. However, this reduction is less in the Southern parts of the as the system's higher efficiency in winter dominates the overall decrease. The application of MPC can further reduce the cost and energy consumption of the system by 35% theoretically. However, the accuracy of model prediction affects its performance in practical applications, which can be mitigated by employing technologies such as machine learning and reinforcement learning. Further research is required to verify these technologies.</p>
<p>The DSHP+DPUTB system, a type of TES-integrated GSHP, has been well-designed and demonstrated superior performance to conventional systems, with greater flexibility and thermal efficiency. As a result, this system can enable electrification in the space heating sector without requiring an escalation in the grid. Moreover, alternative controls can be utilized to exploit its decarbonization potential fully.</p>
|