• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 58
  • 58
  • 52
  • 47
  • 24
  • 13
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Evaluation of the efficiency of polymerization of composite resins in proximal restorations / Avaliação da qualidade de polimerização de resinas compostas em restaurações proximais

Obeid, Alyssa Teixeira 27 March 2019 (has links)
Statement of the problem. The insertion and polymerization of the first resin composite layer in the proximal cavity of class II restorations require attention to achieve cervical sealing as well as good physical properties and clinical longevity. Objective. To evaluate the polymerization efficiency of four resin composites (Filtek Z250XT- 3M ESPE, Filtek One Bulk-Fill-3M ESPE, Filtek Bulk-Fill Flow-3M ESPE and Opus Bulk Fill- FGM) in the cervical region of class II restorations. Material and methods. Sixteen groups (n = 12) were prepared by inserting 2mm increments of the resin composites in a bipartite matrix and being cured with a lightsource of 1000mW/cm2 in continuous mode during 20 or 40 seconds directly on the material (M group) or through a slot preparation (S group) in typodont teeth and all were stored at 37 +/- 1°C, for 24 hours. The Knoop microhardness was evaluated with 25-g-load and 5-s dwell time. Data were analysed with three-way Anova and Tukeys HSD ( = 5%). Results. The results of relative hardness did not show significant difference for the M groups, regardless of the time and type of resin. All the resins had a relative hardness higher than 0.80. In contrast, for S groups, Z250 20s (0.39+0.08) and Bulk FGM 20s (0.47+0.04) showed significant lowest ratios. Bulk Flow 20s (0.70+0.12) and 40s (0.72+0.09), One Bulk 20s (0.65+0.05) and 40s (0.71+0.06) presented no statistical difference with group Z250 40s (0.63+0.05). Conclusion. It would beneficial to increase the time of photoactivation for resins Z250XT and Bulk FGM, differently for Bulk Flow and One Bulk in class 2 proximal slot restorations to ensure adequate hardening. / Problematização. A inserção e polimerização do primeiro incremento de resina composta na caixa proximal de restaurações classe II deve ser efetuada com atenção para garantir um bom selamento cervical, bem como alcançar boas propriedades físicas e longevidade clínica. Objetivo. Avaliar a eficiência da polimerização de quatro resinas compostas (Filtek Z250XT- 3M ESPE, Filtek One Bulk-Fill-3M ESPE, Filtek Bulk-Fill Flow-3M ESPE e Opus Bulk Fill- FGM) na parede cervical de restaurações classe II. Material e métodos. Dezesseis grupos (n=12) foram preparados através da inserção de incrementos de 2mm das resinas em uma matriz bipartida, sendo fotoativados com uma fonte de luz de 1000mW/cm2 em modo contínuo durante 20 e 40 segundos diretamente no material (M) ou através do preparo slot (S) em um dente artificial e armazenados em estufa a 37 +/- 1ºC, por 24 horas. A microdureza Knoop foi avaliada com carga de 25gramas e tempo de permanência de 5segundos. Todos os grupos foram submetidos aos testes estatísticos e avaliados pela análise de variância com três fatores (Anova) e pelo teste de Tukey HSD ( = 5%). Resultados. Os resultados de dureza relativa não apresentaram diferença significante para os grupos M, independente do tempo e tipo de resina. Todas as resinas apresentaram dureza relativa superior a 0.80. Por outro lado, para os grupos S, Z250 20s (0.39+0.08) e Bulk FGM 20s (0.47+0.04) apresentaram valores significativamente menores. Bulk Flow 20s (0.70+0.12) e 40s (0.72+0.09), One Bulk 20s (0.65+0.05) e 40s (0.71+0.06) não apresentaram diferença estatística com o grupo Z250 40s (0.63+0.05). Conclusão. Seria benéfico aumentar o tempo de fotoativação para as resinas Z250XT e Bulk FGM, ao contrário das resinas Bulk Flow e One Bulk em restaurações de classe 2 com preparo slot para melhorar a dureza.
2

The microhardness of cementum and dentin a thesis submitted in partial fulfillment ... periodontics ... /

Rautiola, Clifton A. January 1960 (has links)
Thesis (M.S.)--University of Michigan, 1960.
3

Análise da qualidade de polimerização, por meio de testes de microdureza, de um cimento resinoso utilizado na cimentação de coroas totais em preparos com diferentes substratos / Analysis of quality of polymerization of a resin cement used to cement ceramic crowns in differents preparation substrates through microhardness tests

Mendonça, Luana Menezes de 27 May 2011 (has links)
O objetivo deste estudo foi avaliar a microdureza do cimento resinoso Variolink II ( Ivoclar Vivadent, Schaan, Liechtenstein) empregado na cimentação de coroas totais de cerâmica (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) em preparos com 3 substratos (dentina, metal e resina composta). Foram utilizados 30 molares distribuídos em 3 grupos de acordo com o tipo de substrato. No grupo com substrato em dentina (D), as coroas foram cimentadas em dentes preparados em dentina. Nos grupos com substrato em metal (M) e resina (R), as coroas foram seccionadas no nível da junção cemento-esmalte e restauradas com núcleos metálicos e de preenchimento em resina composta, respectivamente. Cada um dos grupos foi subdividido em subgrupos para avaliação após 7 dias e 3 meses de armazenamento em água deionizada. Os espécimes foram seccionados no centro das coroas, no sentido vestíbulo-lingual e as superfícies foram polidas para a realização dos testes de microdureza ao longo da linha de cimento. Os valores de microdureza foram obtidos nos terços cervical, médio, oclusal das faces vestibular e lingual e na face oclusal. Os resultados foram submetidos a uma análise estatística prévia ANOVA a 3 critérios (substratos/ armazenamento/ terços e face oclusal), a qual não mostrou diferenças significativas entre os terços e face oclusal nos 2 períodos de armazenamento. Em seguida foi realizada a ANOVA a 2 critérios (substrato e armazenamento) e o teste de Tukey que mostraram os resultados do substrato em resina estatisticamente inferiores aos de dentina e metal, após o período de armazenamento de 7 dias. Conclui-se que a microdureza do cimento resinoso não variou nos diferentes terços e face e que a influência do substrato em resina no cimento foi tempo-dependente. / The aim of this study was to evaluate the microhardness of resin cement Variolink II (Ivoclar Vivadent, Schaan, Liechtenstein) used to cement full ceramic crowns (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) in three preparations substrates (dentin, metal and composite resin). Thirty molars were divided into three groups, according to the type of the substrate. In the dentin substrate group (D), the crowns were prepared in dentin; the metal (M) and resin (R) substrates groups, the crowns were sectioned at cement enamel junction level and restored with metal cast post and composite resin filler, respectively. Each group was subdivided into subgroups to evaluation after 7 days and 3 months of storage in deionized water. After cementing the specimens were sectioned buccolingually at the center of the crowns, and the surfaces were polished to microhardness test along the cement line. The microhardness values were obtained in the cervical, medium and occlusion thirds of the buccal and lingual surfaces and in the occlusal surface. The results were submitted to a three-way ANOVA (substrates / storage / thirds and occlusal surface) to a prior statistical analysis and did not show significant differences between the occlusal surface and thirds in the two storage periods. Then two-way ANOVA (substrate and storage) and the Tukey test were performed. The results in the resin group were statistically lower than those of dentin and metal, after 7 days of storage. Therefore, the microhardness of resin cement did not change in the different thirds and face and that the influence of the resin substrate was time-dependent.
4

Efeito de um infiltrante resinoso no tratamento de lesões de mancha branca: análise in vitro e in situ / Efffect of a resinous infiltrant on the tratment of white spot lesions: in vitro and in situ analysis

Freitas, Maria Cristina Carvalho de Almendra 10 April 2015 (has links)
Dentre as estratégias de tratamento de lesões incipientes de cárie, no estágio de mancha branca ativa, o infiltrante resinoso tem sido empregado, preenchendo os poros do esmalte e impedindo a sua progressão. O objetivo deste trabalho foi avaliar o efeito do infiltrante de cárie (Icon®) sobre lesões cariosas artificiais produzidas por diferentes protocolos e a eficiência deste tratamento após novo desafio ácido por modelos experimentais in vitro e in situ, utilizando a microdureza de superfície (MS) e longitudinal (ML). Na fase in vitro, lesões cariosas artificiais foram produzidas em 45 espécimes de esmalte bovino (6x4mm) através de três diferentes protocolos (ciclagem DES-RE, gel MC e solução MHDP). Os espécimes foram tratados com o infiltrante e submetidos a novo desafio ácido por ciclagem DES-RE. Este delineamento resultou em 4 condições em um mesmo espécime: hígida (H), após a desmineralização (D), após o tratamento com o infiltrante (I) e após o novo desafio ácido (N). Na fase in situ, 15 voluntários usaram dispositivos palatinos contendo dois espécimes por 14 dias, induzindo a lesão por meio de gotejamento de solução de sacarose 8x/dia. Nas duas fases, a MS e ML foram avaliadas em todas as condições dos espécimes até 220&#x3BC;m. Os dados foram coletados e processados pela porcentagem da diferença com os valores iniciais da condição hígida para serem analisados estatisticamente de acordo com ANOVA (medidas repetidas) e teste de Tukey (p<0,05). No estudo in vitro e in situ todos os protocolos de desmineralização foram capazes de produzir lesões de cárie de subsuperfície. Todos os protocolos in vitro promoveram perda de dureza de superfície maior que 75%, enquanto o protocolo in situ promoveu quase 40%. Há uma redução da perda de dureza à medida que a profundidade aumenta em todos os casos, sendo as particularidades mais observadas até 50 &#x3BC;m. O infiltrante avaliado em todas as condições foi capaz de re-equilibrar parcialmente a dureza interna, entretanto sua resistência e efeito após o novo desafio ácido apresentou-se limitado. / Among the strategies for early caries lesions treatment as active white spot, the resin infiltrant has been employed filling the enamel pores and preventing their progression. The aim of this study was to evaluate the effect of caries infiltrant (Icon®) on artificial carious lesions produced by different protocols, and the efficiency of this treatment after new challenge acid by in vitro and in situ experimental models, using the surface microhardness (SH) and cross-sectional microhardness (CSH). In the in vitro phase, artificial carious lesions were performed on 45 enamel bovine specimens (6x4mm) by three different protocols (DE-RE cycling, MC gel and MHDP solution). The specimens were treated with the infiltrant and subjected to a new challenge by DE-RE cycling. This design resulted in four conditions at the same specimen: sound (S), after demineralization (D), after the treatment with infiltrant (I) and after the new acid challenge (N). In the in situ phase, 15 volunteers wore intraoral appliances containing two specimens for 14 days, inducing the lesion formation by sucrose solution dripping 8x/day. In both models, SH and CSH were evaluated in all conditions of the specimens up to 220&#x3BC;m. Data were collected and processed as percentage from the difference to each condition compared to sound stage to be statistically analyzed with ANOVA (repeated measures) and Tukey test (p <0.05). For all tested conditions, demineralization protocols were able to produce subsurface carious lesions. All in vitro protocols promoted hardness loss higher than 75% while in situ protocol promoted almost 40%. There is a reduction in the hardness loss as the depth increases, in which the main differences can be noticed up to 50&#x3BC;m. The infiltrant evaluated in all conditions was able to partially re-balance the internal hardness, however its strength and effect after the new challenge acid had been limited.
5

"Estudos do desenvolvimento e caracterização das ligas Cu-Ni-Pt e Cu-Ni-Sn para fins eletro-eletrônicos" / STUDIES OF THE DEVELOPMENT AND CHARACTERIZATION OF THE Cu-Ni-Pt AND Cu-Ni-Sn ALLOYS FOR ELETRO-ELECTRONIC USES

Silva, Luis Carlos Elias da 04 October 2006 (has links)
O Cu e suas ligas têm diferentes aplicações na sociedade moderna devido as excelentes propriedades elétricas, condutividade térmica, resistência à corrosão dentre outras propriedades. Estas aplicações podem ser em válvulas, tubulações, panelas para absorção de energia solar, radiadores para automóveis, condutores de corrente e eletrônico, elementos de termostatos e partes estruturais de reatores nucleares, como, por exemplo, bobinas para campo toroidal para um reator de fusão nuclear. Dentre as ligas utilizadas em reatores nucleares, podemos destacar Cu-Be, Cu-Sn e Cu-Pt. O Ni e o Co, freqüentemente são adicionados às ligas de Cu para que a solubilidade seja deslocada para temperaturas mais elevadas com relação aos sistemas binários de Cu-Sn e Cu-Pt. A adição de Ni-Pt ou Ni-Sn ao Cu em porcentagens iguais ou inferiores a 1,5 % aliado a tratamentos termos-mecânico alteram as propriedades do Cu. Estudamos neste trabalho sete diferentes ligas: três ligas de Cu-Ni-Pt 1 (97,99 % Cu - 1,55 % Ni - 0,46 % Pt), 2 (99,33 % Cu - 0,23 % Ni -0,43 % Pt) 3 (98,01 % Cu - 0,48 % Ni - 1,51 % Pt); três ligas de Cu-Ni-Sn 4 (98,31% Cu - 1,12 % Ni - 0,58 % Sn), 5 (98,79 % Cu – 0,57 % Ni - 0,65 % Sn), 6 (98,39% Cu – 0,46 % Ni – 1,16 % Sn) e Cu eletrolítico 0 (0,0058 % Pb - 0,0007 % Fe - 0,0036 % Ni - 0,0024 % Ag). As referentes ligas foram desenvolvidas a partir de um forno a arco voltaico e passaram por tratamentos termo-mecânicos pré-determinados. As microestruturas foram analisadas diretamente por microscopia óptica e microscopia eletrônica de varredura / EDS e indiretamente por medidas de dureza Vickers e condutividade elétrica. O objetivo deste trabalho, portanto, foi observar e constatar os efeitos da mudança da microestrutura em relação às propriedades dureza e condutividade elétrica. / The Cu and its alloys have different applications in the owed modern society the excellent electric properties, thermal conductivity, resistance to the corrosion and other properties. These applications can be in valves, pipes, pots for absorption of solar energy, radiators for automobiles, current driver, electronic driver, thermostats elements and structural parts of nuclear reactors, as, for example, reels for field toroidal for a reactor of nuclear coalition. The alloys used in nuclear reactors, we can highlight Cu-Be, Cu-Sn and Cu-Pt. Ni and Co frequently are added to the Cu alloys so that the solubility is moved for temperatures more elevated with relationship to the binary systems of Cu-Sn and Cu-Pt. The addition of Ni-Pt or Ni-Sn to the Cu in the same or inferior percentages to 1,5% plus thermomechanical treatments changes the properties of the copper. We studied the electric conductivity and hardness Vickers of the Cu-Ni-Pt and Cu-Ni-Sn and compared with the electrolytic Cu. In the proposed flowcharts, breaking of the obtaining of the ingot, we proceeded with thermo mechanical treatments.
6

Comparação de diferentes pré-tratamentos de superfície na remineralização de esmalte com flúor em tratamento de lesões com mancha branca e sua resistência após desafio ácido / Comparison of different pretreatments on remineralization of enamel white spot lesions with fluoride and its resistance after new acidic challenge

Araújo, Diana Ferreira Gadêlha de 03 June 2016 (has links)
A aplicação de flúor tópico é a principal estratégia de natureza química para a remineralização de lesões incipientes (LI) clinicamente visíveis como manchas brancas (MB) por cárie. Abordagens para aumentar a retenção de F no substrato pode favorecer sua ação e para isso, tratamentos prévios da superfície do esmalte podem ser usados. O objetivo deste trabalho foi comparar a capacidade de remineralização do flúor sem e com pré-tratamento do esmalte com ácido fosfórico e nitrato de alumínio e a sua resistência após novo desafio. Sessenta espécimes de esmalte bovino foram preparados (6mm x 4mm) e selecionados por meio de análise de microdureza de superfície (MS). LI foram produzidas através de ciclagem Desmineralização-Remineralização (DES-RE) e os espécimes divididos aleatoriamente em cinco grupos, de acordo com o tratamento (n=12): V- controle (verniz de fluoreto de sódio 5% por 4 horas), F (sem pré-tratamento); P-F(condicionamento ácido com ácido fosfórico por 30s); Al-F (nitrato de alumínio a 0,05M por 1min); P-Al-F (condicionamento com ácido fosfórico a 37% + nitrato de alumínio a 0,05M). Os tratamentos foram repetidos semanalmente durante quatro semanas. Após o tratamento, os espécimes foram submetidos à nova ciclagem ácida. Após cada etapa, nova MS foi realizada e ao final das análises, um corte transversal dos espécimes foi realizado. Uma das metades foi submetida à análise da microdureza longitudinal (ML) e a outra preparada para realização da microrradiografia transversal (TMR) para a análise de conteúdo mineral perdido. O percentual de perda de dureza de superfície (%PDS) foi analisado por ANOVA a 2 critérios de medidas repetidas e Tukey e o percentual de perda de dureza longitudinal (%PDL) por ANOVA a 3 critérios de medidas repetidas e Tukey (p<0,05). Os dados de TMR no parâmetro LD (profundidade da lesão) foram analisados por ANOVA a dois critérios (p<0,05). Os resultados mostraram que a ciclagem DES-RE resultou em significante %PDS e %PDL em todos os grupos. Grupo F revelou menor perda de MS após tratamento e, F, Al-F e P-Al-F, mostraram menor perda de dureza final, após o novo desafio ácido. Na análise de %PDL, o grupo V apresentou menor perda de dureza final quando comparado com os demais grupos, nas diferentes profundidades. A análise do conteúdo mineral não revelou nenhuma diferença entre os tratamentos e fases. Nenhum dos pré tratamentos propostos foram capazes de otimizar a atuação do gel APF na remineralização de MB. / The topical fluoride is the main chemical strategy to remineralize incipient caries lesions (ICL) visible as carious white spot lesions (WSL). Approaches to increase the fluoride retention may favor its action and therefore, enamel pretreatments can be used for this purpose. The aim of this study was to compare the potential of fluoride remineralization with and without previous enamel pretreatment with aluminum nitrate and phosphoric acid as well as their resistance after a new acid challenge. Sixty bovine enamel specimens were prepared (6mm x 4mm) and selected by the surface hardness (SH) analysis. The ICL were produced using DE-RE cycling and the specimens were randomized in five groups, according to the treatment (n=12): Vcontrol (5% sodium fluoride varnish during 4h), and four groups previously preatreated with topical application of acidulated phosphate fluoride (APF) during 4min: F (without pretreatment), P-F (phosphoric acid etching during 30s), Al-F (0.05M aluminum nitrate during 1min); P-Al-F (phosphoric acid etching + aluminum nitrate). The treatments were performed weekly during four weeks. After the treatment, the specimens were submitted to the new acid challenge. After each step, a new SH analysis was performed followed by the transversal cut of the specimens. A half was submitted to the longitudinal cross-sectional hardness analysis (LH) and the other half was prepared to transverse microradiography assessments (TMR) to determine the loss of mineral content. The percentage of surface mineral loss (%SH) was analyzed using two-way repeated-measures ANOVA and the percentage of crosssectional mineral loss (%LH) by the three-way repeated-measures ANOVA and Tukey (p<0.05). Data of TMR analysis by LD (lesion depth) parameter was analyzed with two-way ANOVA (p<0.05). The results showed significant %SH and %LH after DE-RE cycling for all groups. F group showed the lowest %SH after treatment, with no significant difference to Al-F and P-Al-F after the new acid challenge. V group showed the lowest %LH compared to the other groups, in the different depths, suggesting more resistance. Mineral content assessment did not reveal any difference among treatments and phases. None pretreatments were able to increase the potential of fluoride remineralization.
7

Análise da qualidade da polimerização e da degradação de cimentos resinosos utilizados na cimentação de pinos de fibra de vidro por meio de testes de microdureza / Microhardness analysis of the polymerization quality and degradation of resin cements used for fiber posts cementation

Pedreira, Ana Paula Ribeiro do Vale 16 April 2007 (has links)
Os cimentos resinosos têm sido largamente utilizados em odontologia restauradora com a finalidade de reter o pino intra-radicular e dissipar tensões entre este e a raiz. Entretanto, o grau de conversão alcançado pelos mesmos influencia suas propriedades mecânicas, biocompatibilidade e degradação pela água e pelos ácidos bucais. Testes de microdureza podem ser aplicados para estimar o grau de conversão de compósitos, uma vez que apresentam boa correlação com a espectroscopia infravermelha. Este trabalho objetivou analisar a microdureza de quatro cimentos resinosos de polimerização dual utilizados na cimentação de pinos de fibra de vidro, nos períodos inicial, após 24 horas de imersão em etanol a 75% e após 3 meses de armazenamento em água, e testar a hipótese de que não há diferença entre a microdureza dos terços cervical, médio e apical na linha de cimento. Quarenta incisivos bovinos tratados endodonticamente foram distribuídos em quatro grupos para a cimentação de pinos Fibrekor® (Jeneric/Pentron) de 1mm de diâmetro, sendo: Grupo 1 - Panavia F 2.0 (Kuraray Medical Inc.), Grupo 2 - Variolink (Ivoclar), Grupo 3 - Rely X Unicem (3M ESPE) e Grupo 4 - Duolink (Bisco). Após a cimentação, as raízes foram divididas em 2 subgrupos, sendo 5 seccionadas após 7 dias para análise da microdureza inicial e 5 mantidas íntegras em água deionizada por 3 meses, para avaliação da microdureza final no microdurômetro Shimadzu HMV (Japan). Após a mensuração inicial, as raízes seccionadas eram armazenadas a 37º C por 24h em 10mL de solução de etanol a 75%, e reavaliadas. Foram identificadas diferenças estatisticamente significativas entre cimentos, terços e períodos (inicial ou após 24h de imersão em etanol a 75%), bem como interações entre cimento/terços e cimento/períodos de avaliação. O cimento Panavia exibiu os valores de microdureza inicial significativamente superiores, sem diferença estatística entre os demais cimentos. Os valores de microdureza inicial por terços não seguiram um padrão homogêneo; os cimentos Variolink e Duolink exibiram valores de microdureza significativamente superiores no terço cervical, sem diferença significativa entre os terços para os demais cimentos. A imersão em etanol reduziu significativamente a média dos valores de dureza para todos os cimentos; o comportamento por terços variou em função do material. O armazenamento em água por 3 meses não exerceu influência sobre a dureza da maioria dos cimentos, com exceção do Unicem, que exibiu aumento significativo dos valores de dureza após esse período. Portanto, a hipótese proposta neste estudo foi rejeitada. / Resin cements have been largely used in dentistry for retaining intraradicular posts and to minimize tension between them. However, the degree of conversion influences mechanical properties, biocompatibility and susceptibility of water and acid degradation of these polymers. Hardness tests are used to estimate the degree of conversion of composites, as it shows good correlation with infrared spectroscopy. The aim of this study was to evaluate the microhardness of four resin cements used for fiber posts cementation at the nitial period, 24h-immersion in a 75% ethanol solution and after 3-month water storage. Forty bovine incisives were endodontically treated and restored with 1mm diameter Fibrekor® posts (Jeneric/Pentron), being: Group 1 - Panavia F 2.0 (Kuraray Medical Inc.), Group 2 - Variolink (Ivoclar), Group 3 - Rely X Unicem (3M ESPE) and Group 4 - Duolink (Bisco). After cementation, each group was divided in two subgroups: 5 roots were sectioned 7 days after cementation for initial hardness measurement and 5 roots were immersed in deionized water for 3 months for final hardness measurements using Shimadzu Micro Hardness Tester (HMV, Japan). After the initial measurements, the sectioned roots were immersed in 10mL 75% ethanol solution for 24h at 37ºC, and tested again. Differences in hardness values have been detected among resin cements, radicular thirds and periods (initial or 24h-immersion in a 75% ethanol solution). Data also revealed significant interaction to cement/third and cement/period of evaluation. Panavia showed higher hardness values, with no statistical differences among the other cements. It was not verified a homogeneous pattern regarding radicular third; Variolink and Duolink exhibited higher hardness values for the cervical third, without differences among radicular thirds for the other cements. Hardness values decreased after ethanol immersion for all resin cements and the hardness according to radicular thirds varied among the materials. The hardness of tested resin cement showed no influence after 3-month water storage, except for Unicem as it showed an increase in Knoop hardness after this period. Therefore, the null hypotesis proposed was rejected.
8

INFLUÊNCIA DE DIFERENTES TRANSLUCIDEZ DAS CERÂMICAS SOBRE O GRAU DE CONVERSÃO E MICRODUREZA DE UM CIMENTO RESINOSO DUAL / Influence of different ceramic translucency on the degree of conversion and microhardness of dual resin cement

Sakamoto Junior, Antonio Setsuo 24 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:20Z (GMT). No. of bitstreams: 1 Antonio S Sakamoto Jr.pdf: 1530054 bytes, checksum: 0cc1d22fb0f1bb5e13c6f006184f113e (MD5) Previous issue date: 2012-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The proposition of this study was to evaluate the influence of different ceramic translucency on the degree of conversion and Knoop microhardness of dual resin cement. It was made 150 samples of the resin cement dual cured Variolink II (shade A3; 5 mm in diameter and 1 mm thick) were created with interposing ceramic discs with 8 mm in diameter and 1.5 mm thick varying translucency (IPS e.max HT, HO, ZirPress HT and IPS d.SIGN). The control group was created without the interposition of ceramics. The experimental groups were photoactivated in three different times: 20, 40 and 60 seconds. 75 specimens were measured by Fourier transformed infrared spectroscopy (FTIR) to assess the degree of conversion (%). Another 75 specimens were used for the microhardness test, previously they were ground under water irrigation with grit silicon carbide granulation 320, 400, 600, 1000, 1200, finishing them with felt cloth and diamond paste with grain 1 and ¼ micrometers. Each sample was divided into four quadrants and conducted an indentation in each quadrant and then was calculated the average of these indentations. The values of the degree of conversion and Knoop hardness were analized by two-way ANOVA (type of ceramic and time of photoactivation), Bonferroni’s multiple comparison tests with a significance level of 5% and the Spearman correlation. The degree of conversion values of ceramic with high translucency were similar to the control group, the HO group presented the lowest conversion values, however when the curing time has tripled from 20 to 60 seconds, the values increased 63.9%. Translucent ceramic without infrastructure (IPS d.SIGN) presented higher microhardness values than ceramics with lithium disilicate infrastructure-based (e.max HT and HO). The negative effects of increased opacity of the ceramic on the dual resin cement can be avoided with increased time of photoactivation. / A proposição deste trabalho foi avaliar a influência de cerâmicas de diferentes translucidez sobre o grau de conversão (GC) e microdureza Knoop de um cimento resinoso dual. Foram confeccionados 150 corpos de prova do cimento resinoso dual Variolink II (cor A3; 5 mm de diâmetro e 1 mm de espessura) interpondo discos cerâmicos com 8 mm de diâmetro e 1,5 mm de espessura variando-se a translucidez da cerâmica (IPS e.max HT, HO, ZirPress HT e IPS d.SIGN). O grupo controle foi confeccionado sem interposição da cerâmica. Os grupos experimentais foram fotoativados em 3 diferentes tempos: 20, 40 e 60 segundos. Para o grau de conversão (%) foram utilizados 75 corpos de provas, onde foram mensurados através da Espectroscopia por infra vermelho por transformação de Fourier (FTIR). Para o teste de microdureza foram usados 75 corpos de prova, onde estes foram lixados sob irrigação de água com lixas de carbeto de silício de granulação 320, 400, 600, 1000, 1200, finalizando-os com pano de feltro e pasta diamantada com granulação de 1 e ¼ μm. Cada corpo de prova foi divido em 4 quadrantes erealizado uma indentação em cada quadrante e em seguida foi calculado a média destas indentações. Os valores do grau de conversão e de microdureza Knoop foram submetidos à análise de variância de dois fatores (tipo de cerâmica e tempo), pós-teste de Bonferroni com nível de significância de 5% e à correlação de Spearman. Os valores de GC para as cerâmicas de alta translucidez foram semelhantes ao grupo controle, o grupo HO apresentaram os menores valores de GC, porém obteve um aumento de 63,9% quando o tempo de fotoativação foi triplicado de 20 para 60 segundos. Já os valores de microdureza superficial foram maiores para as cerâmicas com maior translucidez sem infraestrutura (IPS d.SIGN), as cerâmicas com infraestrutura à base de dissilicato de lítio (e.max HT e HO). Os efeitos negativos da maior opacidade da cerâmica sobre o cimento resinoso dual podem ser evitados com aumento no tempo de fotoativação.
9

Efeito de um infiltrante resinoso no tratamento de lesões de mancha branca: análise in vitro e in situ / Efffect of a resinous infiltrant on the tratment of white spot lesions: in vitro and in situ analysis

Maria Cristina Carvalho de Almendra Freitas 10 April 2015 (has links)
Dentre as estratégias de tratamento de lesões incipientes de cárie, no estágio de mancha branca ativa, o infiltrante resinoso tem sido empregado, preenchendo os poros do esmalte e impedindo a sua progressão. O objetivo deste trabalho foi avaliar o efeito do infiltrante de cárie (Icon®) sobre lesões cariosas artificiais produzidas por diferentes protocolos e a eficiência deste tratamento após novo desafio ácido por modelos experimentais in vitro e in situ, utilizando a microdureza de superfície (MS) e longitudinal (ML). Na fase in vitro, lesões cariosas artificiais foram produzidas em 45 espécimes de esmalte bovino (6x4mm) através de três diferentes protocolos (ciclagem DES-RE, gel MC e solução MHDP). Os espécimes foram tratados com o infiltrante e submetidos a novo desafio ácido por ciclagem DES-RE. Este delineamento resultou em 4 condições em um mesmo espécime: hígida (H), após a desmineralização (D), após o tratamento com o infiltrante (I) e após o novo desafio ácido (N). Na fase in situ, 15 voluntários usaram dispositivos palatinos contendo dois espécimes por 14 dias, induzindo a lesão por meio de gotejamento de solução de sacarose 8x/dia. Nas duas fases, a MS e ML foram avaliadas em todas as condições dos espécimes até 220&#x3BC;m. Os dados foram coletados e processados pela porcentagem da diferença com os valores iniciais da condição hígida para serem analisados estatisticamente de acordo com ANOVA (medidas repetidas) e teste de Tukey (p<0,05). No estudo in vitro e in situ todos os protocolos de desmineralização foram capazes de produzir lesões de cárie de subsuperfície. Todos os protocolos in vitro promoveram perda de dureza de superfície maior que 75%, enquanto o protocolo in situ promoveu quase 40%. Há uma redução da perda de dureza à medida que a profundidade aumenta em todos os casos, sendo as particularidades mais observadas até 50 &#x3BC;m. O infiltrante avaliado em todas as condições foi capaz de re-equilibrar parcialmente a dureza interna, entretanto sua resistência e efeito após o novo desafio ácido apresentou-se limitado. / Among the strategies for early caries lesions treatment as active white spot, the resin infiltrant has been employed filling the enamel pores and preventing their progression. The aim of this study was to evaluate the effect of caries infiltrant (Icon®) on artificial carious lesions produced by different protocols, and the efficiency of this treatment after new challenge acid by in vitro and in situ experimental models, using the surface microhardness (SH) and cross-sectional microhardness (CSH). In the in vitro phase, artificial carious lesions were performed on 45 enamel bovine specimens (6x4mm) by three different protocols (DE-RE cycling, MC gel and MHDP solution). The specimens were treated with the infiltrant and subjected to a new challenge by DE-RE cycling. This design resulted in four conditions at the same specimen: sound (S), after demineralization (D), after the treatment with infiltrant (I) and after the new acid challenge (N). In the in situ phase, 15 volunteers wore intraoral appliances containing two specimens for 14 days, inducing the lesion formation by sucrose solution dripping 8x/day. In both models, SH and CSH were evaluated in all conditions of the specimens up to 220&#x3BC;m. Data were collected and processed as percentage from the difference to each condition compared to sound stage to be statistically analyzed with ANOVA (repeated measures) and Tukey test (p <0.05). For all tested conditions, demineralization protocols were able to produce subsurface carious lesions. All in vitro protocols promoted hardness loss higher than 75% while in situ protocol promoted almost 40%. There is a reduction in the hardness loss as the depth increases, in which the main differences can be noticed up to 50&#x3BC;m. The infiltrant evaluated in all conditions was able to partially re-balance the internal hardness, however its strength and effect after the new challenge acid had been limited.
10

Análise do efeito de adição do marcador Rodamina B em propriedades mecânicas de sistemas adesivos não simplificados / Analysis of the effect of addition of Rhodamine B marker on mechanical properties of non-simplified adhesives

Machado, Camila Moreira 12 December 2014 (has links)
Este estudo in vitro avaliou o efeito da adição de rodamina B dissolvida em etanol nas concentrações de 0,02mg/mL e 0,10mg/mL, nas propriedades mecânicas dos sistemas adesivos não simplificados considerados padrão-ouro. 96 coroas de terceiros molares humanos hígidos foram seccionadas transversalmente no terço oclusal para remoção do esmalte e exposição da dentina. Os espécimes foram divididos de acordo com os sistemas adesivos Adper Scotchbond Multi-Purpose (MP) - convencional de três passos ou Clearfil SE Bond (SE) - autocondicionante de dois passos: MP-C e SE-C (MP e SE controles); MP-C1 e SE-C1 (MP e SE com rodamina B 0,02mg/mL); MP-C2 e SE-C2: (MP e SE com rodamina B 0,10mg/mL). Para o teste de RU, os espécimes (n=10) foram submetidos ao desgaste com lixas de granulação 320 e 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e restaurada com resina composta FiltekTM Z250. Após o armazenamento em saliva artificial (7dias/37oC), os espécimes foram seccionados para obtenção de palitos com 0,64 mm2 de área média e submetidos ao teste de microtração em máquina de teste universal a 0,5 mm/min, que foram analisados após 7 dias e 6 meses. O modo de fratura dos espécimes foi analisado com estereomicroscópio digital (x200) e classificado em: adesiva, coesiva em dentina, coesiva em resina e mista. Para o teste de MS, as coroas seccionadas (n=6) foram planificadas com lixa de granulação 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e os espécimes foram mantidos secos em estufa a 37oC durante 48 horas. O teste de MS foi realizado utilizando ponta Knoop (Microdurômetro Shimadzu HMV-2), a 10x e carga estática de 25gF por 10 segundos. Os resultados obtidos foram analisados por análise de variância (ANOVA-2 critérios) e teste de Bonferroni para comparações múltiplas (p<0,05). A análise de acordo com o tempo foi realizada com o teste de t-student. Os valores médios de RU e desvio padrão (MPa±dp; 7 dias / 6 meses) foram: MP-C (41,95±2,38 / 22,76±3,66); MP-C1 (28,02±5,12 / 17,93±5,70); MP-C2 (26,28±5,55 / 14,30±5,68); SE-C (46,07±1,43 / 19,07±6,75); SE-C1 (37,49±13,31 / 18,54±6,71); SE-C2 (34,16±7,71 / 17,89±4,87). No tempo de 7 dias, os fatores sistema adesivo e concentração de rodamina B foram significantes. Após 6 meses, apenas o fator concentração de rodamina B foi significante. A falha de fratura predominante em todos os grupos foi adesiva. Os valores de MS (KHN) e desvio padrão foram: MP-C (8,97±3,85); MP-C1 (7,33±0,99); MP-C2 (7,17±2,45); SE-C (4,71±4,42); SE-C1 (4,42±0,56); SE-C2 (3,27±0,30). Na comparação entre os sistemas adesivos, eles diferiram entre si na condição controle e de 0,10mg/mL. Para cada adesivo, não houve diferença entre as distintas condições de acordo com a adição de rodamina B. Em função dos resultados apresentados, a adição de rodamina B nos sistemas adesivos não simplificados MP e SE, nas concentrações de 0,02mg/mL e 0,10mg/mL, deve ser incorporada com cautela para que não influencie nas propriedades mecânicas do material. / This in vitro study evaluated the effect of addition of rhodamine B dissolved in ethanol in concentrations of 0.02mg/mL and 0.10mg/mL, the mechanical properties of non-simplified adhesive systems. 96 crowns of human third molars were transversely sectioned on the oclusal third to remove the enamel and exposure the dentin. The specimens were divided according to the adhesive systems Adper Scotchbond Multi-Purpose (MP) 3-step-etch-andrinse or Clearfil SE Bond (SE) 2-step-self-ecthing: MP-C and SE-C (MP and SE controls); MP-C1 and SE-C1 (MP and SE with 0.02mg/mL rhodamine B); MP-C2 and SE-C2: (MP and SE with 0.10mg/mL rhodamine B). For the &#x3BC;TBS test, the specimens (n=10) were ground with 320- to 600-grit silicon carbide paper. The dentin was treated according to the instructions of each manufacturer and restored with composite resin FiltekTM Z250. The specimens were stored in artificial saliva (7 days/37oC), and then sectioned to obtain sticks with an average of 0.64 mm2 area and submitted to &#x3BC;TBS test at a universal testing machine at 0.5 mm/min, which were analyzed immediately after 7 days and 6 months. The mode of fracture of the specimens was analyzed with digital stereomicroscope (x200) and classified as: adhesive, cohesive in dentine, cohesive in resin and mixed. For the SM test, the sectioned crowns (n=6) were flattened with 600-grit silicon carbide paper. The dentin was treated according to the manufacturers instructions for each adhesive system and the specimens were stored in dry condition at 37oC during 48 hours. The SM test was performed with Knoop indenter (Shimadzu HMV-2 hardness tester), at 10x and 25gF of load for 10 seconds. The results were analyzed by two-way analysis of variance tests and the Bonferroni test for multiple comparisons (p<0.05). The analysis regarding time was checked with t-student test. The mean &#x3BC;TBS and standard deviation (MPa±dp; 7 days / 6 months) were: MP-C (41.95±2.38 / 22.76±3.66); MP-C1 (28.02±5.12 / 17.93±5.70); MP-C2 (26.28±5.55 / 14.30±5.68); SE-C (46.07±1.43 / 19.07±6.75); SE-C1 (37.49±13.31 / 18.54±6.71); SE-C2 (34.16±7.71 / 17.89±4.87). In the immediate time, the adhesive system and rhodamine B concentration factors were significant. After 6 months, only the rhodamine B concentration was a significant factor. The predominant failure in all groups was adhesive. The values of SM and standard deviation were: MP-C (8.97±3.85); MP-C1 (7.33±0.99); MP-C2 (7.17±2.45); SE-C (4.71±4.42); SE-C1 (4.42±0.56); SE-C2 (3.27±0.30). In the comparison between the adhesive systems, they were significantly different for the conditions control and 0.10mg/mL. For each adhesive systems, there was no difference between the different conditions according to the addition of rhodamine B. Regarding the shown results, addition of rodhamine B in non-simplified adhesives MP and SE, in the concentrations of 0.02mg/mL e 0.10mg/mL must be carefully added to avoid implications to the mechanical properties of the materials.

Page generated in 0.0621 seconds