• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modelagem da usina fotovoltaica do estádio do Mineirão para estudos de propagação harmônica

Monteiro Júnior, Alcy 16 December 2014 (has links)
Este trabalho apresenta um estudo de medições e simulações de fluxo harmônico na Usina Solar Fotovoltaica do Estádio Mineirão em Belo Horizonte/MG. O objetivo foi verificar o comportamento dos inversores solares fotovoltaicos na geração de harmônicos e a atenuação ocorrida pela agregação de múltiplos inversores. Para isso, foram realizadas medições em seis pontos estratégicos da usina investigada, por meio de analisadores de qualidade de energia, o que possibilitou a verificação do comportamento da usina em horários distintos e condições climáticas diversas. Foi avaliada a injeção de harmônicos no sistema elétrico pelos inversores e comparados os valores com os limites previstos em normas, procedimentos e recomendações vigentes. Além disso, o modelo completo da usina foi desenvolvido e simulado utilizando os softwares OpenDSS, ANAH e PowerFactory para análise harmônica e sua validação com os dados de medição. Os resultados obtidos indicam boa conformidade das medições e adequações dos modelos desenvolvidos. / This work presents a study of harmonic measurements and flow simulations in Photovoltaic Solar Plant of the Mineirao Stadium in Belo Horizonte/MG. The objective was to verify the behavior of photovoltaic solar inverters in the generation of harmonics and the attenuation occurred by the aggregation of multiple inverters. For this, measurements were performed on six strategic points of the investigated plant through power quality analyzers, allowing the verification of the plant's behavior at different times and different climates. It was evaluated the injection of harmonics in the electrical system for inverters and compared the values with the limits laid down in standards, procedures and current recommendations. In addition, the complete model of the plant was developed and simulated using the OpenDSS, ANAH and PowerFactory softwares to harmonic analysis and its validation with the data measurement data. The results indicate good agreement between measurement and developed models.
2

Metoda merenja harmonika u realnoj distributivnoj mreži primenom A/D konvertora dvobitne rezolucije / Real power grid harmonic measurement method using 2-bit A/D converters

Beljić Željko 29 December 2016 (has links)
<p>U disertaciji je prikazano teorijsko i praktično istraživanje koje se<br />odnosi na utvrđivanje potrebnih i dovoljnih uslova za merenje<br />harmonika u realnoj elektrodistributivnoj mreži. Cilj istraživanja<br />doktorske disertacije je formulisanje merne metode i na metodi<br />baziranom hardveru - po mogućnosti minimalne rezolucije<br />primenjenih A/D konvertora - praktično dvobitnih za merenje<br />harmonika u realnoj elektrodistributivnoj mreži. Jednostavan<br />hardver omogućuje jednostavna paralelna merenja, kao i mali broj<br />izvora sistematske greške merenja, što je vrlo primenljivo u<br />merenjima u realnoj distributivnoj mreži.Simulacionom analizom, a<br />potom i eksperimentom potvrđena je hipoteza istraživanja.</p> / <p>The dissertation shows the theoretical and practical research related to the<br />determination of necessary and sufficient conditions for the measurement of<br />harmonics in a real power grid. The aim of the PhD research is to formulate<br />method and hardware based on the measurement method - preferably with<br />minimal resolution of applied A/D converter - practically 2-bit, for harmonics<br />measurement in a real power grid. Simple hardware allows simple parallel<br />measurements, as well as a small number of systematic measurement error,<br />which is applicable for measurement in the real power grid. Simulation<br />analysis, followed by the experiment, confirmed the hypothesis of this<br />research.</p>

Page generated in 0.0696 seconds