• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Antenne versatile intriquée / Versatile intricate antenna

Damaj, Lana 13 March 2013 (has links)
Cette thèse vise à développer des antennes large bande à double polarisation avec un filtre et un dispositif d’adaptation d’impédance et d’alimentation intégrés, que nous avons définies comme antennes versatiles intriquées. La largeur de la bande et la double polarisation permettent d’utiliser l’antenne avec différents standards et donc d’être versatile. D'autre part, le filtre pour rejeter les harmoniques supérieurs et le réseau d'adaptation sont des parties intégrantes de l'élément rayonnant et lui confèrent le caractère intriqué. La première étude porte sur la conception d'une antenne large bande à double polarisation avec un filtre intégré dans le dispositif d’alimentation. Le filtre permet de rejeter les harmoniques indésirables. La structure complète est compacte et de dimensions 0.9 λ0x0.9 λ0, λ0 étant la longueur d’onde en espace libre à la fréquence basse. Afin d’augmenter la compacité, nous présentons ensuite une antenne à suppression des harmoniques (HSA : Harmonic Suppressed Antenna) large bande à simple et à double polarisation. Ce travail explore les différentes techniques utilisées pour concevoir une HSA. Dans cette approche, l'élément rayonnant, le filtre qui permet de rejeter le rayonnement d’harmoniques hors bande et le réseau d'adaptation, qui sont traditionnellement des circuits séparés, sont intégrés dans une seule unité compacte. La taille totale de l'antenne est 0.53 λ0x0.53 λ0. Le dernier chapitre présente une des HSA développées associée à un conducteur magnétique artificiel non-uniforme. Cette structure permet l’obtention d’une antenne large bande de faible épaisseur et directive. / This thesis aims to develop wideband antennas interrelated with a filter, which we have defined as versatile intricate antennas. The antenna is versatile as it provides wide bandwidth (more than one octave) and has the capability to generate two orthogonal polarizations. On the other hand, the filter for harmonic rejection and the matching network are integrated parts of the radiating element and give it the intricate character.The first study is concentrated on designing a dual polarized antenna with a wide stop filter integrated to the feeding network. This filter enables to reject harmonics and unwanted response. The complete structure is compact with a size of 0.9 λ0x0.9 λ0, λ0 being the free space wavelength at the lowest frequency. In order to improve the compactness of the whole system and to cover more standards, we present a single and dual polarized wideband Harmonic Suppressed Antenna (HSA). This work explores the different techniques used to design a HAS. The proposed antenna is simple in structure but versatile in applications. In this approach, radiating element, filter for harmonic rejection and matching network, which are traditionally separated circuits, are incorporated into a single compact unit. The total size of the antenna is 0.53 λ0x0.53λ0. The final chapter aims to study the previous intricate antenna with a new wideband Artificial Magnetic Conductor (AMC) structure as reflector in order to obtain a low profile and directive antenna.
2

Estudo, projeto e implementação de sistemas UPQC/UPS trifásicos aplicados no condicionamento ativo de energia elétrica / Study, design and implementation of an UPQC/UPS systems applied in three-phase active power conditioning

Modesto, Rodrigo Augusto 11 February 2015 (has links)
Este trabalho apresenta o estudo, análise e a implementação de três topologias de condicionadores ativos de energia elétrica, utilizados para a melhoria da qualidade da energia em sistemas elétricos trifásicos a quatro fios. Estes condicionadores de qualidade de energia podem trabalhar tanto como um condicionador unificado de qualidade de energia (UPQC), bem como uma fonte de alimentação ininterrupta (UPS), permitindo: (i) a supressão das correntes harmônicas da carga; (ii) a compensação de energia reativa da carga; (iii) compensação dos desequilíbrios das correntes de carga; (iv) a compensação de desequilíbrios de tensão da rede; (v) supressão das tensões harmônicas da rede elétrica; (vi) a regulação das tensões de saída (tensões de carga); e (vii) fornecimento de energia ininterrupta para as cargas críticas (sistema UPS). Dentre as três topologias de UPQC/UPS estudadas, uma delas é proposta neste trabalho com o intuito de reduzir a tensão no barramento CC. Além disso, todas as topologias em estudo são constituídas por dois conversores PWM, nos quais é adotada uma estratégia de controle dual. Desse modo, o conversor colocado em paralelo com a carga, funciona como uma fonte de tensão senoidal, enquanto que o conversor colocado em série entre a rede elétrica e a carga, é controlado para operar como uma fonte de corrente senoidal. Tanto os controladores de tensão, quanto os de corrente são implementados no referencial síncrono dq0. Além disso, a técnica de modulação vetorial espacial tridimensional (3-D-SVM) é empregada nos conversores. Testes experimentais são apresentados para validar o desenvolvimento teórico e verificar o bom desempenho estático e dinâmico dos condicionadores ativos de energia elétrica, operando como UPQC, bem como sistema UPS. / This work presents the study, analysis and implementation of three topologies of active power conditioners, which are used to improve the power quality in three-phase four-wire systems. These power quality conditioner can work as unified power quality conditioner (UPQC), as well as an uninterruptible power supply (UPS) system allowing: (i) suppression of load harmonic currents; (ii) compensation of load reactive power; (iii) load unbalances compensation; (iv) utility voltage unbalances compensation; (v) utility voltage harmonics suppression; (vi) regulation of the output voltages (load voltages); and (vii) uninterruptible power for critical loads when working as UPS system. Among the three topologies of UPQC/UPS studied, one of them is proposed in this work in order to reduce the DC-bus voltage. Besides, all the topologies are comprised of two PWM converters, where a dual control strategy is adopted. The first converter, which is placed in parallel with the load, operates as a sinusoidal voltage source, while the second, which is placed in series between the utility grid and the load, is controlled to operate as a sinusoidal current source. Both the voltage and current controllers are implemented into the synchronous rotating reference frame (dq0-axes). In addition, the series and parallel converters use the three-dimensional space vector modulation (3-D-SVM) technique. The experimental tests are presented to validate the theoretical development and to verify the effective static and dynamic performance of the proposed active power conditioners, operating as UPQC and UPS.
3

Estudo, projeto e implementação de sistemas UPQC/UPS trifásicos aplicados no condicionamento ativo de energia elétrica / Study, design and implementation of an UPQC/UPS systems applied in three-phase active power conditioning

Rodrigo Augusto Modesto 11 February 2015 (has links)
Este trabalho apresenta o estudo, análise e a implementação de três topologias de condicionadores ativos de energia elétrica, utilizados para a melhoria da qualidade da energia em sistemas elétricos trifásicos a quatro fios. Estes condicionadores de qualidade de energia podem trabalhar tanto como um condicionador unificado de qualidade de energia (UPQC), bem como uma fonte de alimentação ininterrupta (UPS), permitindo: (i) a supressão das correntes harmônicas da carga; (ii) a compensação de energia reativa da carga; (iii) compensação dos desequilíbrios das correntes de carga; (iv) a compensação de desequilíbrios de tensão da rede; (v) supressão das tensões harmônicas da rede elétrica; (vi) a regulação das tensões de saída (tensões de carga); e (vii) fornecimento de energia ininterrupta para as cargas críticas (sistema UPS). Dentre as três topologias de UPQC/UPS estudadas, uma delas é proposta neste trabalho com o intuito de reduzir a tensão no barramento CC. Além disso, todas as topologias em estudo são constituídas por dois conversores PWM, nos quais é adotada uma estratégia de controle dual. Desse modo, o conversor colocado em paralelo com a carga, funciona como uma fonte de tensão senoidal, enquanto que o conversor colocado em série entre a rede elétrica e a carga, é controlado para operar como uma fonte de corrente senoidal. Tanto os controladores de tensão, quanto os de corrente são implementados no referencial síncrono dq0. Além disso, a técnica de modulação vetorial espacial tridimensional (3-D-SVM) é empregada nos conversores. Testes experimentais são apresentados para validar o desenvolvimento teórico e verificar o bom desempenho estático e dinâmico dos condicionadores ativos de energia elétrica, operando como UPQC, bem como sistema UPS. / This work presents the study, analysis and implementation of three topologies of active power conditioners, which are used to improve the power quality in three-phase four-wire systems. These power quality conditioner can work as unified power quality conditioner (UPQC), as well as an uninterruptible power supply (UPS) system allowing: (i) suppression of load harmonic currents; (ii) compensation of load reactive power; (iii) load unbalances compensation; (iv) utility voltage unbalances compensation; (v) utility voltage harmonics suppression; (vi) regulation of the output voltages (load voltages); and (vii) uninterruptible power for critical loads when working as UPS system. Among the three topologies of UPQC/UPS studied, one of them is proposed in this work in order to reduce the DC-bus voltage. Besides, all the topologies are comprised of two PWM converters, where a dual control strategy is adopted. The first converter, which is placed in parallel with the load, operates as a sinusoidal voltage source, while the second, which is placed in series between the utility grid and the load, is controlled to operate as a sinusoidal current source. Both the voltage and current controllers are implemented into the synchronous rotating reference frame (dq0-axes). In addition, the series and parallel converters use the three-dimensional space vector modulation (3-D-SVM) technique. The experimental tests are presented to validate the theoretical development and to verify the effective static and dynamic performance of the proposed active power conditioners, operating as UPQC and UPS.

Page generated in 0.0716 seconds