Spelling suggestions: "subject:"heart rate monitoring."" "subject:"peart rate monitoring.""
21 |
Role of nNOS in the autonomic control of cardiac excitability in cardiac physiological and pathophysiological statesHeaton, Daniel Anthony January 2005 (has links)
No description available.
|
22 |
Validation of the SenseWear HR Armband for measuring heart rate and energy expenditureCrawley, Manuella Barbosa. January 2008 (has links)
Thesis (M.Ed.)--Cleveland State University, 2008. / Abstract. Title from PDF t.p. (viewed on July 7, 2008). Includes bibliographical references (p. 33-36). Available online via the OhioLINK ETD Center. Also available in print.
|
23 |
Description of fetal heart rate patterns at 20 to 24 weeks gestationHofmeyr, Franelise 12 1900 (has links)
Thesis (MMed)--Stellenbosch University, 2012. / ENGLISH ABSTRACT: Introduction - Accurate computerized analysis of the fetal heart rate (FHR) pattern has become more feasible and clinically relevant in recent years. Taking into account advances in neonatal care resulting in a declining lower limit for fetal viability as well as research into fetal effects of maternal high risk behaviour and escalating intra-uterine exposure to harmful toxins and drugs, fetal heart rate patterns need to be more accurately described in earlier gestations than what is currently available in literature. With advancing technology it is becoming possible to accurately record and interpret the FHR patterns from gestations as early as 20 weeks' gestation. By using the Monica AN24 transabdominal electrocardiographic fetal monitor and product specific software, we analysed early FHR patterns according to the Dawes-Redman criteria, as used in later gestations. Methods - The aim of our study was to describe patterns of FHR (short-term variability, basal heart rate, accelerations and decelerations) at 20-24 weeks' gestation. Physiological data were obtained from the routine second trimester fetal assessment by the Monica AN24 monitor as used in the Safe Passage Study. As of December 31, 2009, 411 participants completed their first fetal assessment and met our inclusion criteria. Because our aim was the description of patterns in pregnancies with a normal outcome, we excluded all adverse neonatal outcomes, preterm deliveries, babies with low birth weights as well as cases where delivery data were lost. After recordings of poor technical quality were also removed from our data pool, 281 recordings remained for analysis. Results - Distinct FHR patterns and quantifiable parameters of heart rate variability were consistently observed. In contrast to what has previously been published, accelerations of the FHR and reassuring baseline variation are present from as early as 20 weeks. Conclusion - Information from this study provides an important foundation for further studies of early FHR patterns and it will help us better assess the fetus at a crucial age for indicators of good outcome at early delivery. / AFRIKAANSE OPSOMMING: Inleiding - Akkurate gerekenariseerde ontleding van die fetale hartpatroon het in die afgelope paar jaar meer tegnologies haalbaar met toenemende kliniese toepassing geword. Tans ervaar ons besondere vooruitgang in neonatale sorg en dus dalende grense vir vroeë lewensvatbaarheid in kliniese praktyk. Daar is ook 'n toename in navorsing oor moederlike hoë risiko gedrag tydens swangerskap en die effek hiervan op die ontwikkeling die fetus asook die neonatale uitkomste. Akkurater beskrywing van fetale hartpatrone in vroeëre gestasies as wat huidiglik in die literatuur beskikbaar is, is dus genoodsaak om die effekte van blootstelling op die fetus waar te neem. Met vooruitgang in tegnologie is dit nou moontlik om deur nie-indringende elektrokardiografie, fetale hartpatrone te registreer en te interpreteer van so vroeg as 'n swangerskapsdurte van 20 weke. Deur die gebruik van die Monica AN24 transabdominale monitor en produk-spesifieke programmatuur, kon ons vroeë fetale hartpatrone ontleed volgens die Dawes-Redman kriteria wat gewoonlik in later swangerskapsduurtes gebruik word. Metodes - Die doel van ons studie was die beskrywing van verskeie fetale hartpatrone (naamlik korttermyn variasie, basale hartspoed, versnellings asook vestadigings) rondom 20 – 24 weke swangerskapsduurte.
Fisiologiese data is in die tweede trimester verkry deur die Monica AN24 monitor, soos gebruik word in die voortgaande Veilige Geboorte Studie by Tygerberg hospitaal. Tot en met 31 Desember 2009, het 411 deelnemers hulle eerste fetale evaluasie vir die Veilige Geboorte Studie gehad en ook voldoen aan die insluitingskriteria van hierdie projek.
Aangesien ons fokus die beskrywing van hartpatrone in normale swangerskappe was, het ons alle nie-wenslike neonatale uitkomste, voortydse verlossings, babas met lae geboorte gewig asook gevalle waarvan die geboortedata nie beskikbaar was nie, uitgesluit. Alle opnames met sub-standaard tegniese kwaliteit is ook verwyder uit ons finale data vir ontleding, wat ons met 281 opnames gelaat het vir hierdie studie. Resultate -
Duidelike fetale hartpatrone en meetbare afmetings is deurgangs opgemerk. In teenstryd met wat voorheen gedokumenteer is, is die teenwoordigheid van versnellings asook gerusstellende basislyn variasie meetbaar vanaf 20 weke gestasie. Samevatting - Informasie vanaf hierdie studie verskaf 'n belangrike grondslag vir verdere projekte in die ontleding van fetale hartpatrone met die fokus op ondersoek van vroeë voorspelling van goeie neonatale uitkomste.
|
24 |
The effect of misoprostol on fetal heart rate parameters during induction of labour from 38 weeks gestation : a retrospective auditFeketshane, Anthony M. 12 1900 (has links)
Thesis (MMed)-- Stellenbosch University, 2013. / ENGLISH ABSTRACT: Misoprostol is often used for the purpose of induction of labour. However, its effect on fetal heart rate has not been systematically studied. Objective
To assess the effect of misoprostol on fetal heart rate parameters during induction of labour from 38 completed weeks in women with previous intrauterine death or postterm pregnancy.
Study design
A retrospective descriptive study of 127 women for a period of 18 months.
Method
Women who underwent induction of labour with misoprostol for either previous intrauterine death or postterm pregnancy at Tygerberg hospital were eligible.
The selected process of induction of labour happened according to the departmental protocol. The primary outcomes were changes in fetal heart rate (variability, accelerations and decelerations) pre-and post-administration of misoprostol. Secondary outcomes were neonatal highcare or intensive care unit (ICU) admissions.
Results
There was no statistical difference in the mean fetal heart rate and baseline variability in relation to time recordings after administration of misoprostol. There were no statistically significant differences in the distribution of accelerations and decelerations in different time intervals before and after administration. There were more reactive patterns at all time intervals after the administration of misoprostol, but these differences did not quite reach statistical significance. In both study groups no neonatal complications or intensive care admissions were reported.
Conclusion
In the absence of contra indications, 50mcg of oral misoprostol can be given to mothers for induction of labour as no harmful fetal heart tracing abnormalities were found for 45 minutes; however large prospective randomized controlled trials are still needed to confirm effectiveness and evaluate further maternal and neonatal safety issues. Optimal dose and frequency also still need robust interrogation. Based on this thesis it does appear that misoprostol is probably not harmful to the fetus under these circumstances. / AFRIKAANSE OPSOMMING: Misoprostol word dikwels gebruik vir induksie van kraam. Die effek daarvan op fetale hartspoed is egter nie sistematies ondersoek nie.
Doel
Om die effek van misoprostol op fetale hartspoedparameters gedurende die induksie van kraam van 38 voltooide weke in vroue met vorige intra-uteriene dood or oortyd swangerskap te evalueer.
Studei-ontwerp
„n Retrospektiewe beskrywende studie van 127 vroue oor „n periode van 18 maande.
Metode
Vroue wat induksie van kraam met misoprostol ondergaan het vir of vorige intra-uteriene dood of oortyd swangerskap by Tygerberg Hospitaal is ingesluit.
Die proses van induksie van kraam is volgens departementele protokol uitgevoer. Die primêre uitkomste was veranderinge in fetale hartspoed (variasie, versnellings en verstadigings) pre- en post-toediening van misoprostol. Neonatale hoësorg of intensiewe sorg toelatings was sekondêre uitkomste. Resultate
Ons het geen statistiese verskille in gemiddelde fetale hartspoed en basislynvariasie in verhouding tot die tyd na toediening van misoprostol gevind nie. Daar was geen statisties betekenisvolle verskille in die verspreiding van versnellings en verstadigings in verskillende tydsintervalle nie. Daar was meer reaktiewe patrone gedurende alle tydsintervalle na die toediening van misoprostol, maar hierdie verskille was nie statisties betekenisvol nie. In beide studiegroepe was daar geen neonatale komplikasies of intensiewe sorg toelatings nie.
Gevolgtrekking
In die afwesigheid van kontra-indikasies kan 50 mcg misoprostol aan moeders toegedien word vir induksie van kraam aangesien geen skadelike fetale hartsped abnormaliteite gevind is nie. Groot prospektiewe gerandomiseerde gekontroleerde studies word steeds benodig om effektiwiteit te bevestig en om moederlike en fetale veiligheidskwessies verder te evalueer. Optimale dosis en frekwensie benodig ook robuuste ondersoek. Gebaseer op hierdie tesis kom dit voor of misoprostol waarskynlik nie skadelik vir die fetus onder hierdie omstandighede nie.
|
25 |
Assessment of energy expenditure and physical activity intensity through simultaneous use of heart rate monitoring and accelerometryKirschner, Monica M. 23 May 2012 (has links)
In order to have a complete understanding of the relationship between physical activity (PA) and health, it is essential to be able to accurately assess PA in free-living situations. The purpose of this study was to use three accelerometers located on the dominant ankle, hip, and wrist and a heart rate (HR) monitor to estimate energy expenditure (EE) compared to measured EE while completing activities of daily living (ADL). The regression equation developed showed a significant relationship (P < 0.05) with EE. Together, HR and the hip-worn accelerometer explained 73.4% of the variance in EE with HR accounting for 59.3% (P < 0.05). Type of activity, the wrist-, and ankle-worn accelerometer each explained an additional 5%, 3% and 3% of the variance in EE, respectively (P < 0.05). The regression equation developed is a good predictor of EE during selected ADL, and allows researchers to more accurately quantify free-living PA. / School of Physical Education, Sport, and Exercise Science
|
26 |
Underwater measurements of heart rateLiaw, Hibisca 14 January 2013 (has links)
The objective of this project is to develop a device that can monitor the heart rate and respiration of cetaceans. This would provide a way to quantitatively measure stress and determine the impact of human activity on cetaceans, especially for certain species that have been difficult to monitor in the past. There are many challenges to developing such a device, including determining the appropriate type of sensor, reducing the effect of flow noise, and designing an effective attachment method; this paper primarily focuses on determining the most suitable acoustic transducer. Experiments were conducted to compare various acoustic sensors in detecting heart rate. The electronic stethoscope performed the best in the experiments, but the results showed that other transducers, such as accelerometers and pressure sensors, also performed well and could be successful options with further development. Data processing methods to identify heartbeats and characterize signals are also discussed in this paper. Future work on the project involves subsequent tests to address other design variables as well as replicate experiments on animals.
|
27 |
Heart rate response and ECG monitoring in veteran squash players.Sibbald, Helen. January 1997 (has links)
The incidence of sudden death during or after squash play has become a source of concern. In order to screen for coronary artery disease, exercise stress testing has been advocated, by the American College of Sports Medicine (1986), for those at or above the age of 45 already exercising or before embarking on exercise. Eighteen veteran squash players (mean age 49 ± 3 yr) took part in the study. Heart rate response was monitored throughout a squash match and for an hour after play. ECG changes were monitored for one hour after squash play. Mean heart rate, throughout playing time was 148 ± 16 beats per minute (range 118 - 168 bpm), representing 86.7% of Predicted Maximum Heart Rate (PMHR). Mean maximal heart rate was 169 ± 14 bpm (range 141 - 186 bpm), representing 98.8% of PMHR. Thus squash represents a very high intensity activity for these players. On subsequent ECG monitoring, no abnormalities were detected. The results of this study confirm that squash is an extremely high intensity sport and that even veteran players play at a level close to their maximal. This level of play did not provoke subsequent cardiac arrhythmias in this small group of players, contrary to an earlier study that reported arrhythmias in one third of a group of younger players in the post match period. / Thesis (M.Med.Sc.)-University of Natal, 1997.
|
28 |
Data analysis through auditory display : applications in heart rate variabilityBallora, Mark. January 2000 (has links)
This thesis draws from music technology to create novel sonifications of heart rate information that may be of clinical utility to physicians. Current visually-based methods of analysis involve filtering the data, so that by definition some aspects are illuminated at the expense of others, which are decimated. However, earlier research has demonstrated the suitability of the auditory system for following multiple streams of information. With this in mind, sonification may offer a means to display a potentially unlimited number of signal processing operations simultaneously, allowing correlations among various analytical techniques to be observed. This study proposes a flexible listening environment in which a cardiologist or researcher may adjust the rate of playback and relative levels of several parallel sonifications that represent different processing operations. Each sonification "track" is meant to remain perceptually segregated so that the listener may create an optimal audio mix. A distinction is made between parameters that are suited for illustrating information and parameters that carry less perceptual weight, which are employed as stream separators. The proposed sonification model is assessed with a perception test in which participants are asked to identify four different cardiological conditions by auditory and visual displays. The results show a higher degree of accuracy in the identification of obstructive sleep apnea by the auditory displays than by visual displays. The sonification model is then fine-tuned to reflect unambiguously the oscillatory characteristics of sleep apnea that may not be evident from a visual representation. Since the identification of sleep apnea through the heart rate is a current priority in cardiology, it is thus feasible that sonification could become a valuable component in apnea diagnosis.
|
29 |
A comparison of children's heart rates during physical education class and recess timeWerling, Beverly A. January 1997 (has links)
This study investigated the heart rates of children in the first, third, and fifth grades of two schools during physical education class and recess time. One hundred and nine children (56 females, 53 males) participated in the eight-week study. Each participant wore a Polar Vantage XL receptor strap and watch receiver during physical education class and recess time on the same day. The average heart rates and percentage of time in and above the target heart zone of 150 to 200 beats per minute were recorded. A MANOVA analysis revealed no significant difference between heart rates during physical education and recess over the eight-week period. Gender differences, however, were significant as boys average heart rates were higher than girls and boys were in or above the target heart zone a higher percentage of the time than girls. This difference was especially evident at recess. / Fisher Institute for Wellness
|
30 |
Heart rate and reaction time differences in high and low ability adults' letter and word identification /Keeter, Amanda, January 1900 (has links)
Thesis (M.S.)--Missouri State University, 2008. / "December 2008." Includes bibliographical references (leaves 21-22). Also available online.
|
Page generated in 0.0886 seconds