• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Simple flow-reversible models for dynamics and control of heat exchangers.

Shoureshi, R. (Rahmatallah) January 1978 (has links)
Thesis. 1978. M.S.--Massachusetts Institute of Technology. Dept. of Mechanical Engineering. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND ENGINEERING. / Includes bibliographical references. / M.S.
2

Dynamic response of a cooling and dehumidifying coil to variations in air flow rate

葉啓明, Ip, Kai-ming. January 1997 (has links)
published_or_final_version / Mechanical Engineering / Master / Master of Philosophy
3

Pressure drop for a two-phase flow of steam across vertical tube banks

Hearn, Janice Herman. January 1979 (has links)
Call number: LD2668 .T4 1979 H43 / Master of Science
4

Prediction and measurement of the performance of spray cooled heat exchangers

Kriel, Dawid Eduard 01 1900 (has links)
Thesis (MEng) -- Stellenbosch University, 1991. / ENGLISH ABSTRACT: In the present study various mathematical models have been developed for the analysis of spray cooled finnned-tube heat exchangers. These models range from simplified models based on the work by Kreid et al. [78KR1], Nakayama et al. [88NA1] and Erens et al. [90ER1] to a more comprehensive model based on the work by Poppe [84P01]. Computer programs were written to evaluate the performance prediction of these models on spray cooled heat exchangers in the vertical air flow mode. Experimental tests were conducted on a four-row finned-tube heat exchanger in a vertical air /water mist flow to verify the mathematical models and it was found that the performance of this heat exchanger could be predicted within 20 per cent using the accurate model. Significant performance enhancement (up to 3.5 times the dry performance) was found by spraying relatively small amounts of water onto the heat exchanger. The spray water massflow rate was found to have a significant effect on the two phase pressure drop across the heat exchanger. The present study indicated certain important factors which have to be taken into consideration when designing spray cooled heat exchanger units. These include the geometry of the finned-tubes, the temperature difference between the process water and the optimum air and the air /spray water ratio. / AFRIKAANSE OPSOMMING: In die tesis is 'n aantal wiskundige modelle ontwikkel wat gebruik kan word vir die analise van sproei verkoelde vinbuis warmte uitruilers. Die wiskundige modelle wissel van eenvoudige modelle wat gebaseer is op die werk van Kreid et al. [78KR1 ], Nakayama et al. [88NA1] en Erens et al. [90ER1] tot 'n omvattende model wat gebaseer is op die werk van Poppe [84 PO 1]. Rekenaar programme is geskryf om die die modelle se voorspellingsvermoe van die kapasiteit van sproei verkoelde warmte uitruilers te evalueer. 'n Eksperimentele ondersoek is gedoen op 'n warmte uitruiler met vier vinbuis rye in 'n toetsseksie met vertikale lugvloei. Die toets resultate is gebruik vir die evaluasie van die wiskundige modelle en het getoon dat die akkurate model se voorspellings binne 20 per sent van die gemete kapasitiet van die uitruiler val. Die eksperirnentele werk het verder aangetoon dat deur klein hoeveelhede water op die uitruiler te sproei, 'n toename in kapasiteit tot 3.5 keer die droe werkverrigting moontlik is. Die twee-fase drukval oor die uitruiler is sterk bei:nvloed deur die sproei water massavloei. Die analitiese navorsmg wat gedoen is met behulp van die rekenaar programme het aangedui dat daar 'n paar belangrike faktore is wat in ag geneem moet word met die ontwerp van sproei verkoelde warmte uitruilers. Die faktore sluit die vinbuis geometrie, die temperatuur verskil tussen die proses water en lug en optimum lug/sproeiwater massavloei verhouding in.
5

Dynamic simulation of the Fast Flux Test Facility primary system

Sands, Mark Richard January 1981 (has links)
No description available.

Page generated in 0.3727 seconds