• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 149
  • 62
  • 32
  • 15
  • 9
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 3
  • 2
  • 2
  • Tagged with
  • 383
  • 383
  • 63
  • 54
  • 46
  • 43
  • 40
  • 37
  • 34
  • 34
  • 33
  • 32
  • 30
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Thermal/fluid characteristics of cylindrical-filament open-cell box-lattice structures as heat exchanger surfaces

Balantrapu, Kiran. January 2006 (has links)
Thesis (M.S.)--University of Nevada, Reno, 2006. / "May 2006." Includes bibliographical references (leaves 46-48). Online version available on the World Wide Web.
112

Thermal performance of plain-weave screen as a heat exchanger surface in parallel plate free convection

Soma Shekar, Sidigonde. January 2004 (has links)
Thesis (M.S.)--University of Nevada, Reno, 2004. / "December 2004." Includes bibliographical references (leaves 43-46). Online version available on the World Wide Web.
113

An experimental study of co-flow ammonia-water desorption in an oil-heated, microscale, fractal-like branching heat exchanger

Mouchka, Gregory A. 24 March 2006 (has links)
An experimental study was performed in which an ammonia-water solution was desorbed within a branching fractal-like microchannel array. The solution entered in the center of a disk, and flowed out radially until discharging in to a gravity-driven separation chamber. Heat was added to the ammonia-water through a thin wall, above which flowed heat transfer oil in a separate branching fractal-like microchannel array. Such arrays have been shown to utilize the increased heat transfer coefficients seen in parallel channel arrays; however, they do so with a lower pressure drop. An experimental flow loop consisting of ammonia-water and heat transfer oil sub-loops was instrumented along with a test manifold for global measurements to be taken. Temperature, pressure, density and mass flow rate measurements permitted calculation of desorption and heat transfer characteristics. Parameters included oil mass flow rate, oil inlet temperature, and strong solution flow rate, while strong solution concentration, temperature, and weak solution pressure were kept constant. The desorber was assumed to achieve equilibrium conditions between the vapor and weak solution in the separation chamber. The exit plenum was large and acted as a flash chamber, making the assumption reasonable. The vapor mass fraction was determined from knowledge of the weak solution saturation temperature. Heat exchanger analyses (LMTD and ε-NTU) were done to determine the heat transfer characteristics of the desorber. Calculated values of UA are shown to be as high as 5.0 W/K, and desorber heat duties were measured as high as 334 W. Strong solution, at 0.30 mass fraction, was desorbed into weak solution and vapor with concentrations ranging from 0.734 to 0.964. Circulation ratios, defined as strong solution mass flow rate per unit desorbed vapor mass flow rate, varied in this study from 3.4 to 20. A method for specifying desorber operating conditions is described, in which a minimum desorber heat input per unit vapor flow rate is determined at an optimum circulation ratio. A description of how the circulation ratio behaves as a function of strong solution mass flow rate, oil flow rate, and the maximum temperature difference between oil and ammonia-water solution is shown. / Graduation date: 2006
114

Characterization of the Advanced Plant Experiment (APEX) passive residual heat removal system heat exchanger

Stevens, Owen L. 07 June 1996 (has links)
The Oregon State University (OSU) Radiation Center (RC) is the location of a one quarter scale model of the Westinghouse Electric Corporation advanced light-water nuclear reactor design called the AP-600. The full scale AP-600 is a 600 megawatt electric nuclear power plant that incorporates unique passive systems to perform the safety functions currently required of all existing nuclear power plants. Passive safety refers to a system's ability to perform its desired function using natural forces such as gravity and natural circulation. This reduces the reliance on active systems to assure plant safety. The Advanced Plant Experiment (APEX) at the OSU RC is an electrically heated simulation of the AP-600 that includes the Nuclear Steam Supply System (NSSS) and all of the passive safety systems. The APEX facility was funded by the United States Department of Energy and the Westinghouse Electric Corporation. The facility was built to perform the long term cooling tests necessary for design certification of the AP-600. The data taken will be used to benchmark the thermal hydraulic computer codes applied in the design certification process and to better understand the phenomena involved in the full scale AP-600. This paper presents the analysis of the Passive Residual Heat Removal System (PRHR) and in particular the PRHR's "c"-shaped heat exchanger (PRHR Hx). This paper includes analysis and modeling of the PRHR Hx including: hydraulic flow parameters, heat rejection capability, an empirical correlation for determining pressure drop, and an examination of the flow phenomena that occurs in the tank in which the heat exchanger is installed. / Graduation date: 1997
115

The influence of cross-winds on the performance of natural draft dry-cooling towers /

Du Preez, Abraham Francois. January 1992 (has links)
Dissertation (Ph. D.)--University of Stellenbosch, 1992. / Bibliography. Also available via the Internet.
116

Fouling characteristics of a desalted crude oil

Lin, Dah-cheng 24 August 1990 (has links)
The fouling characteristics of a desalted crude oil were investigated in a systematic investigation. There are two main parts in this study, the dry bulk tests (dehydrated crude oil) and the wet bulk tests (to which desalter brine was added). Three barrels of desalted crude oil provided by Amoco Oil Company were studied. For the dry bulk tests, no brine was added to the crude oil. The effects of fluid velocity and surface temperature on fouling were investigated. The higher the surface temperature the greater the fouling was observed. Fouling decreased with an increase of fluid velocity. Fluid velocity had a stronger effect on fouling at low surface temperatures than at high surface temperatures. It was also observed that the fouling behavior of crude oil depended on small difference in composition. The threshold surface temperatures for the initiation of fouling were 400-450 °F (3.0 ft/sec), 525-550 °F (5.5 ft/sec), 550-600 °F (8.0 ft/sec) and about 600 °F (10.0 ft/sec) for Barrel No. 2 and Barrel No. 3. For Barrel No. 1 however, the threshold surface temperatures were about 550 °F (3.0 ft/sec) and 600 °F (5.5 ft/sec). For the wet bulk tests, a certain amount desalter brine (weight percentage = 0.8%) was added to the crude oil for each run. The effects of fluid velocity, surface temperature and the presence of brine on fouling were investigated. Higher surface temperature enhanced fouling considerably. Fouling was reduced as fluid velocity was increased. It was shown that brine had a strong effect on fouling. No fouling occurred for velocities of 5.5 and 8.0 ft/sec at a surface temperature of 350 °F which was a condition for which an aqueous phase was present and the salt remained in solution. Significant fouling occurred for velocities of 5.5 and 8.0 ft/sec at a surface temperature operated at a low 400 °F (Tb = 300 °F) which was a condition for which the aqueous phase at the heat transfer surface was dissolved or boiled to extinction and the salt was deposited on the heat transfer surface. / Graduation date: 1991
117

An analysis of water for water-side fouling potential inside smooth and augmented copper alloy condenser tubes in cooling tower water applications

Tubman, Ian McCrea. January 2003 (has links)
Thesis (M.S.)--Mississippi State University. Department of Mechanical Engineering. / Title from title screen. Includes bibliographical references.
118

Thermoacoustic heat pumping study : experimental and numerical approaches /

Duthil, Eric Patxi. January 2003 (has links)
Thesis (Ph. D.)--Hong Kong University of Science and Technology, 2003. / Includes bibliographical references (leaves 122-129). Also available in electronic version. Access restricted to campus users.
119

Numerical analysis of the performance of staggered pin-fin micro heat exchangers /

Choo, Jui Sheng. January 2003 (has links) (PDF)
Thesis (M.S. in Engineering Science)--Naval Postgraduate School, December 2003. / Thesis advisor(s): Ashok Gopinath. Includes bibliographical references (p. 83-84). Also available online.
120

Dynamic analysis of triple heat exchangers by the finite element method

袁大偉, Yuen, Da-wai, David. January 1989 (has links)
published_or_final_version / Mechanical Engineering / Master / Master of Philosophy

Page generated in 0.0483 seconds