• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • No language data
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sensible Air to Air Heat Recovery Strategies in a Passive House

Rodriguez-Anderson, Santiago Martin 08 January 2015 (has links)
Due to rising energy costs and concerns about global climate change, high performance buildings are more in demand than ever before. With roughly 20% of the total energy consumption in the United States being devoted to residential use, this sector represents a significant opportunity for future savings. There are many guidelines and standards for reducing building energy consumption. One of the most stringent is the Passive House Standard. The standard requires that that air infiltration is less than or equal to 0.6 air changes per hour at a 50 Pascal pressure difference (ACH 50), annual heating energy is less than or equal to 15kWh/m2, and total annual source energy is less than or equal to 120 kWh/m2. For comparison, the typical West coast US residence has an ACH50 of 5 and annually uses more than 174 kWh/m2 of source energy according to the 2009 Residential Energy Consumption Survey. With these challenging requirements, successful implementation of the Passive House Standard requires effective strategies to substantially reduce energy consumption for all end uses. Heating and cooling loads are low by necessity in a Passive House. As such this makes end uses like water heating a much larger fraction of total energy use than they would be in a typical building. When air to water heat pumps are employed the energy consumption by water heating is lowered significantly. By employing innovative heat recovery strategies the energy consumption for water heating and HVAC can be reduced even further. This study uses energy modeling and project cost analysis to evaluate three innovative control strategies. Results for a Passive House in Portland Oregon show a savings of about $70 annually with a payback period of 10 years. The same Passive House in Fairbanks Alaska with a different strategy would save $150 annually with a payback period of 5 years.

Page generated in 0.0743 seconds