1

Resorption cycle heat pump with ammonia-water working fluid

Molyneaux, Glenn Arthur January 2000 (has links)
No description available.
2

REDUCTION OF THE COSTS IN A HOUSE IN VALBO THAT USES ELECTRICITY AS ENERGY SOURCE : Study of the installation of a heat pump or connection to the district heating

OrdeÑana, Ianire January 2008 (has links)
<p>The analyzed building in this project is located in Valbo, 9016 Stiftelsev 6. This house is a property of Gavlegårdarna, and it is being used as a house for disabled people. The building consists on five apartments, with one patient in each apartment. Some social workers help those patients in everything they need, making their living in the house as easy as possible.</p><p>The aim of this project is to find out the best option of reducing the energy consumption in this house. There are some alternatives to reduce the energy or the energy costs as; efficiency measures, load management and energy conversion.</p><p>This project is focused on the energy conversion for reducing the energy consumption. As it is the best option for obtaining a considerable reduction in the annual costs.</p><p>First of all the energy balance of the house is analyzed. By studying the energy balance it is possible to find out how the energy consumption of the house is divided. On one hand there is the heat supplied and on the other hand the heat losses.</p><p>As it was said before this project is focused in the reduction of the energy consumption by means of converting to another energy supplying method. Two alternatives have been studied: the installation of a heat pump and the connection to the district heating of Gävle.</p>
3

REDUCTION OF THE COSTS IN A HOUSE IN VALBO THAT USES ELECTRICITY AS ENERGY SOURCE : Study of the installation of a heat pump or connection to the district heating

OrdeÑana, Ianire January 2008 (has links)
The analyzed building in this project is located in Valbo, 9016 Stiftelsev 6. This house is a property of Gavlegårdarna, and it is being used as a house for disabled people. The building consists on five apartments, with one patient in each apartment. Some social workers help those patients in everything they need, making their living in the house as easy as possible. The aim of this project is to find out the best option of reducing the energy consumption in this house. There are some alternatives to reduce the energy or the energy costs as; efficiency measures, load management and energy conversion. This project is focused on the energy conversion for reducing the energy consumption. As it is the best option for obtaining a considerable reduction in the annual costs. First of all the energy balance of the house is analyzed. By studying the energy balance it is possible to find out how the energy consumption of the house is divided. On one hand there is the heat supplied and on the other hand the heat losses. As it was said before this project is focused in the reduction of the energy consumption by means of converting to another energy supplying method. Two alternatives have been studied: the installation of a heat pump and the connection to the district heating of Gävle.
4

Investigating the Impact of Urban Tree Planting Strategies for Shade and Residential Energy Conservation

Hwang, Won Hoi 04 September 2015 (has links)
Expanding urbanization, characterized by increased impervious surfaces and decreased tree canopy, is contributing to rising urban temperatures. This trend has implications for energy consumption, which strategically placed trees can modify by casting shade upon building and ground surfaces. However, urban densification, a paradigm of modern residential land development, often constrains space for planting shade trees. Thus, the overall objective of this dissertation was to investigate shade tree planting strategies and their effects on residential cooling and heating energy conservation for dense urban neighborhoods in U.S. cities on a latitudinal gradient. The first study used a computer program called Shadow Pattern Simulator to examine the effects of tree form, tree placement, and sunlight exposure on shade provision for a residential structure model. Simulation results affirmed the conventional strategy in northern latitudes that recommends planting shade trees on the east or west aspect for maximizing beneficial shade while avoiding tree plantings on the south aspect to minimize any heating penalty of undesirable shade. However, in southern latitudes, planting trees on southerly aspect should not be discounted because the shorter heating season lessens the detrimental heating penalty while providing beneficial season shade. The second study, using an energy simulation program called EnergyPlus, evaluated the effect of a single shade tree upon the energy consumption of the structure model. This study affirmed that energy conservation benefits are influenced by the quantity as well as the quality of tree shade upon building surfaces. In addition, interactions between sun angle, tree form, and tree placement were observed to influence tree shade effects on annual energy consumption. In the third study, based on the first two studies, an alternative tree placement strategy, which reconfigured tree placement around the residential structure, was developed to maximize cooling and heating energy savings while attenuating space conflicts. The alternative strategy was found to be as effective as the conventional strategy while being more responsive to parcel or building orientations in dense urban neighborhoods. Overall, understanding the fundamental interactions between tree form, tree placement, and geographic settings is critical for improving energy conservation benefits of shade trees in dense urban settings. / Ph. D.
5

Hodnocení budovy formou energetického auditu / Evaluation of the building form an energy audit

Blažek, Tomáš January 2018 (has links)
The aim of this master's thesis is elaborating energy audit within current notice 480/2012. The first part of master's thesis deals about history of distrit heating, methods of connection handover, advantages and disadvantages of district heating.The second part analyses consuption energy of assessing bulding. The third part is energy audit.
6

Modelování, simulace a experimentální měření reakce systémů vytápění/vzduchotechniky na požadavky regulace / Modeling, simulation and experimental measurement of reaction of systems heating / ventilation requirements of regulation

Matějíček, Michal January 2019 (has links)
The diploma thesis deals with the behavior of technical systems of the student dormitory in Brno. The temperature and humidity climate was measured and evaluated in the building. The measurement is then compared with the computer simulation created in DesignBuilder. The geometric model of the building was created in Revit, which supports BIM technology. Based on the evaluation of the experiment, the optimization of the technical systems in the building was proposed.
7

Predicting Residential Heating Energy Consumption and Savings Using Neural Network Approach

Al Tarhuni, Badr 30 May 2019 (has links)
No description available.
8

Investigation on the Effects of Indoor Temperature Modulations on Building Energy Usage and Human Thermal Comfort

Traylor, Caleb 05 1900 (has links)
Energy efficiency in the operation of buildings is becoming increasingly important with a growing emphasis on sustainability and reducing environmental impacts of irresponsible energy usage. Improvements have been made both on the technology side of energy efficiency and on the human behavior side. However, when changing human behavior, it is critical to find energy conservation measures that will maintain comfort for occupants. This paper analyzes how this can be done by implementing a modulating temperature schedule based on the concept of alliesthesia, which states that pleasure is observed in transient states. EnergyPlus simulations were used to show that in cooling applications, this type of scheduling can produce significant energy savings. However, energy savings are not predicted for the same type of scheduling for heating applications. Thermal comfort was examined with a cooling experiment and a separate heating experiment, each lasting 45 minutes and taking place during the corresponding season. The experiments showed that modulating temperatures can cause occupants to experience more pleasure than if the temperature remained constant in a cooled space, whereas modulating temperatures had a negative impact on comfort relative to the constant temperature in the heated space. This presents evidence for an ideal opportunity for cooling applications by implementing modulating temperature schedules: an increase in thermal pleasure accompanied by a decrease in cooling energy.
9

Design, fabrication and performance analysis of vacuum glazing units fabricated with low and high temperature hermetic glass edge sealing materials

Memon, Saim January 2013 (has links)
Vacuum glazing is a vital development in the move to more energy efficient buildings. In vacuum glazing, an evacuated cavity supresses gaseous conduction and convection to provide high thermal resistance. A high vacuum pressure (less than 0.1 Pa) is required and must be maintained by a hermetic seal around the periphery, currently formed with either indium (i.e. low temperature sealing method) or solder glass (i.e. high temperature sealing method). This thesis reports the results of an experimental and theoretical investigation into the development of new low temperature (less than 200°C) and novel high temperature (up to 450°C) glass edge seals. A new low temperature composite edge seal was developed in which double and triple vacuum glazings each of dimensions 300x300mm were fabricated with measured vacuum pressures of 4.6x10-2Pa and 4.8x10-2Pa achieved respectively. A three dimensional finite element model of the fabricated design of composite edge sealed triple vacuum glazing was developed.
10

Energetické úspory bytového domu / Energy-savings of a residential building

Michek, Jan January 2018 (has links)
The thesis focuses on energy savings of an apartment building. Firstly, the basic terms concerning apartment building and their costs are explained. Secondly, the thesis looks into energy efficiency of buildings, possibilities of energy savings and methods of economic evaluation of investments. The thesis sets the goal to evaluate current state of a selected apartment building from the perspective of energy efficiency and to propose possible energy saving measures. Lastly, the thesis aims to evaluate proposed measures from economic perspective and the perspective of energy efficiency.