• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da hidrodinâmica do escoamento bifásico água-óleo utilizando o padrão Core Annular Flow. / Hydrodynamics of a liquid-liquid two-phase oil-water flow in a core annular pattern.

Nelize Maria de Almeida Coêlho 12 December 2018 (has links)
A economia mundial é fortemente dependente da disponibilidade de óleo, no entanto as reservas de óleo leve, mais atrativas ao mercado, tendem nos próximos anos ao esgotamento, trazendo à luz as reservas de óleo pesado para atender as demandas do mercado. No entanto, os processos associados ao transporte e processamento desses óleos viscosos consomem muita energia, impondo um grande desafio para a indústria do petróleo. Nesse contexto, se transportar óleos viscosos com água através de um escoamento bifásico em padrão Core Annular Flow (CAF) é muito promissor. Nessa prática, uma película anular de água envolve o núcleo que contém o óleo, minimizando o contato entre este e a parede do duto e reduzindo as perdas de energia por atrito. Visou o presente estudo mapear os padrões de escoamento de óleo pesado com água em dutos horizontais e verticais, mensurar os fatores de redução de potência e do diferencial de pressão associados à um trecho reto e à uma válvula de gaveta aberta e determinar o holdup para avaliar a eficiência do CAF. Para atingir esses objetivos, uma unidade de bancada foi construída, consistindo de tanques de armazenamento e de separação da mistura. Interligando os tanques, foram dispostos dutos transparentes com 27 mm de diâmetro interno e 8 m de extensão, contendo duas seções horizontais e uma vertical para análise e diversos acessórios hidráulicos. O óleo utilizado possuía viscosidade de 3200 cP a 22 °C e densidade de 945 kg/m3 . Os resultados experimentais demonstraram haver diversas configurações de fluxo segundo o posicionamento do duto, e que a diferença de densidade dos fluidos descentraliza o óleo nos escoamentos horizontais. Além disso, o trecho vertical intercalado entre os trechos horizontais se comportou como um retificador de fluxo, melhorando os índices do CAF. Foi determinado um fator de redução de perda de pressão máximo de 250 vezes para o trecho reto e de 12 vezes para a válvula de gaveta. O fator global máximo de redução de potência foi mensurado em 2,2 vezes. Concluiu-se que, para um trecho reto, o projeto de instalações hidráulicas para o escoamento bifásico deve considerar 15 % a mais de perda de carga em relação ao escoamento de água pura. Já para a válvula de gaveta, esse fator deve ser de 700 %. / The world economy is strongly dependent on the availability of oil, however, light oil reserves, more market-oriented, tend to deplete in coming years, bringing to light the heavy oil reserves to meet the demands of the market. However, the processes associated with the transportation and production of these viscous oils consume a lot of energy and pose a great challenge for the oil industry. In this context, transporting viscous oils through a liquid-liquid two-phase oil-water flow in a core annular pattern (CAF) is very promising. In this method, an annular water film surrounds the oil-containing core, minimizing its contact with the pipe wall and reducing energy losses by friction. The aim of the present work was to map the flow patterns of a biphasic oil-water flow in horizontal and vertical pipes, to evaluate the overall energy savings provided by the CAF technique, to measure the pressure gradient reduction factor along the pipe and in a gate valve and to determine the holdup as a way of assessing the energy efficiency of the biphasic oil-water flow transport. To achieve these goals, an experimental facility was built and it consisted of cargo and separation tanks. Connecting these tanks, approximately 8 m of 27mm-ID clear transparent PVC pipes, two horizontal and one vertical sections and various hydraulic fittings. It was used in the tests lubricating oil with 3200 cP and 945 kg/m3 at 22°C and distilled water. The experimental results showed that there are several flow configurations according to the pipe positioning, and that the oil and the water density difference decentralizes the oil core in horizontal flows. In addition, the vertical section placed between the two horizontal ones behaved like a flow rectifier, improving the core annular flow energy savings basis. An average pressure gradient reduction factor of 250 times in a straight pipe and of 12 times in a gate valve was determined. The maximum overall power reduction factor was measured as being 2.2 times. It was concluded that the design of a hydraulic installation to transport heavy oil with water in a core annular pattern should consider a pressure drop increase by a factor of 15 % in a straight pipe and by a factor of 700 % in a gate valve based on the monophasic water transport at similar flow rates.
2

Estudo da hidrodinâmica do escoamento bifásico água-óleo utilizando o padrão Core Annular Flow. / Hydrodynamics of a liquid-liquid two-phase oil-water flow in a core annular pattern.

Coêlho, Nelize Maria de Almeida 12 December 2018 (has links)
A economia mundial é fortemente dependente da disponibilidade de óleo, no entanto as reservas de óleo leve, mais atrativas ao mercado, tendem nos próximos anos ao esgotamento, trazendo à luz as reservas de óleo pesado para atender as demandas do mercado. No entanto, os processos associados ao transporte e processamento desses óleos viscosos consomem muita energia, impondo um grande desafio para a indústria do petróleo. Nesse contexto, se transportar óleos viscosos com água através de um escoamento bifásico em padrão Core Annular Flow (CAF) é muito promissor. Nessa prática, uma película anular de água envolve o núcleo que contém o óleo, minimizando o contato entre este e a parede do duto e reduzindo as perdas de energia por atrito. Visou o presente estudo mapear os padrões de escoamento de óleo pesado com água em dutos horizontais e verticais, mensurar os fatores de redução de potência e do diferencial de pressão associados à um trecho reto e à uma válvula de gaveta aberta e determinar o holdup para avaliar a eficiência do CAF. Para atingir esses objetivos, uma unidade de bancada foi construída, consistindo de tanques de armazenamento e de separação da mistura. Interligando os tanques, foram dispostos dutos transparentes com 27 mm de diâmetro interno e 8 m de extensão, contendo duas seções horizontais e uma vertical para análise e diversos acessórios hidráulicos. O óleo utilizado possuía viscosidade de 3200 cP a 22 °C e densidade de 945 kg/m3 . Os resultados experimentais demonstraram haver diversas configurações de fluxo segundo o posicionamento do duto, e que a diferença de densidade dos fluidos descentraliza o óleo nos escoamentos horizontais. Além disso, o trecho vertical intercalado entre os trechos horizontais se comportou como um retificador de fluxo, melhorando os índices do CAF. Foi determinado um fator de redução de perda de pressão máximo de 250 vezes para o trecho reto e de 12 vezes para a válvula de gaveta. O fator global máximo de redução de potência foi mensurado em 2,2 vezes. Concluiu-se que, para um trecho reto, o projeto de instalações hidráulicas para o escoamento bifásico deve considerar 15 % a mais de perda de carga em relação ao escoamento de água pura. Já para a válvula de gaveta, esse fator deve ser de 700 %. / The world economy is strongly dependent on the availability of oil, however, light oil reserves, more market-oriented, tend to deplete in coming years, bringing to light the heavy oil reserves to meet the demands of the market. However, the processes associated with the transportation and production of these viscous oils consume a lot of energy and pose a great challenge for the oil industry. In this context, transporting viscous oils through a liquid-liquid two-phase oil-water flow in a core annular pattern (CAF) is very promising. In this method, an annular water film surrounds the oil-containing core, minimizing its contact with the pipe wall and reducing energy losses by friction. The aim of the present work was to map the flow patterns of a biphasic oil-water flow in horizontal and vertical pipes, to evaluate the overall energy savings provided by the CAF technique, to measure the pressure gradient reduction factor along the pipe and in a gate valve and to determine the holdup as a way of assessing the energy efficiency of the biphasic oil-water flow transport. To achieve these goals, an experimental facility was built and it consisted of cargo and separation tanks. Connecting these tanks, approximately 8 m of 27mm-ID clear transparent PVC pipes, two horizontal and one vertical sections and various hydraulic fittings. It was used in the tests lubricating oil with 3200 cP and 945 kg/m3 at 22°C and distilled water. The experimental results showed that there are several flow configurations according to the pipe positioning, and that the oil and the water density difference decentralizes the oil core in horizontal flows. In addition, the vertical section placed between the two horizontal ones behaved like a flow rectifier, improving the core annular flow energy savings basis. An average pressure gradient reduction factor of 250 times in a straight pipe and of 12 times in a gate valve was determined. The maximum overall power reduction factor was measured as being 2.2 times. It was concluded that the design of a hydraulic installation to transport heavy oil with water in a core annular pattern should consider a pressure drop increase by a factor of 15 % in a straight pipe and by a factor of 700 % in a gate valve based on the monophasic water transport at similar flow rates.

Page generated in 0.1645 seconds