• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Perda de carga em tubulações comerciais conduzindo água residuária de avicultura / Head loss in the commercial pipelines conducting poultry raising wastewater

Zinato, Cristiano Egnaldo 29 August 2003 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-02-20T15:50:51Z No. of bitstreams: 1 texto completo.pdf: 1265725 bytes, checksum: b031e35d4a63a48d73579d55f531b6e4 (MD5) / Made available in DSpace on 2017-02-20T15:50:51Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1265725 bytes, checksum: b031e35d4a63a48d73579d55f531b6e4 (MD5) Previous issue date: 2003-08-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho foi desenvolvido com os propósitos de avaliar a perda de carga em tubulações comerciais de ferro galvanizado, aço zincado e PVC conduzindo água residuária de avicultura (ARA), determinar equações que a estimem em função da vazão, do diâmetro e da concentração de sólidos totais, bem como levantar as características reológicas da ARA. Os resultados possibilitaram concluir que: (a) a ARA foi classificada reologicamente como plástico de Bingham; (b) as viscosidades de todas as concentrações analisadas apresentaram-se menores que a viscosidade da água; (c) a massa específica das partículas em suspensão na ARA foi de 1,84 g cm -3 e o seu diâmetro menor que 1 mm; (d) a perda de carga da ARA para as concentrações de sólidos totais estudadas foi menor do que para a água limpa, diminuindo até a concentração de 0,4600 dag L -1 e voltando a crescer daí até a concentração de 2,8941 dag L -1 ; (e) os modelos empíricos apresentaram melhores resultados do que o modelo que estima o fator de atrito f. O modelo que melhor estimou a perda de carga foi o de Hazen-Williams modificado, para quaisquer vazões, concentrações de sólidos totais, tipos de materiais e diâmetros de tubos, recomendando-se seu uso em detrimento dos outros modelos. Este modelo subestima, em média, a perda de carga, e apresenta, em geral, os menores erros médios e desvios padrão, justificando seu melhor ajuste, quando comparados aos demais; (f) na prática a variável ST (concentração de sólidos totais) pode ser suprimida da equação para a faixa de ST estudada, considerando-se desprezível o seu efeito no cálculo da perda de carga pelo modelo de Hazen-Williams modificado; (g) uma vez que a perda de carga medida na água limpa foi maior de 9,7 % a 20,8 % para a tubulação de ferro galvanizado de 130,30 mm, de 9,7 % a 32,0 % para a tubulação de aço zincado de 99,83 mm, e de 11,0 % a 26,3 % para a tubulação de PVC de 79,90 mm, comparadas às estimadas pelo modelo de Hazen-Williams modificado para água residuária de avicultura, recomenda-se utilizar equações que determinem a perda de carga para a água limpa no dimensionamento de sistemas hidráulicos que ocasionalmente transportem água residuária de avicultura com as características apresentadas neste trabalho. / The objective of this study was to evaluate the head loss in commercial pipelines made of galvanized iron, zinc-coated steel and PVC conducting poultry raising wastewater (PW), to determine the equations that would estimate this loss as a function of flow rate, pipe diameter and the concentration of the total solids, as well as to determine the rheological characteristics found in poultry raising wastewater (PW), as well as to determine the rheological characteristics of this wastewater. Based on the results, the conclusions were drawn as follows. (a) PW was rheologically classified as Bingham plastic. (b) The viscosity of all analyzed concentrations were lower than that the viscosity of the water. (c) The specific mass of the particles suspended in PW was 1.84 g cm -3 , while the diameter of all these particles were lower than 1 mm. (d) The PW head loss for the studied concentrations of the total solids was lower than that for clean water, as decreasing down to 0.4600 dag L -1 and increasing again up to 2.8941 dag L -1 . (e) The empiric models showed better results than the model estimating the friction factor f. The Hazen-Williams’s modified model was the one that better estimating the head loss for any flow rates, total solid concentrations, material types and pipe diameters, therefore being the most recommended. That model on the average underestimates the head loss and generally presents the lowest average errors and standard deviations, so justifying its adjustment in comparison to the other ones. (f) In the practice, the TS (total solid concentration) may be omitted from the equation at the studied TS range, as its effect is considered as a negligible one when the head loss is calculated by the Hazen Williams’s modified model. (g) Since the head loss measured for clean water showed to be higher than 9.7 to 20.8% for the galvanized-iron 130.30 mm pipeline, than 9.7% to 32.0% for the zinc-acid pipeline, than 11.0 to 26.3% for the PVC 79.90 mm pipeline, comparative to those head losses estimated by the Hazen-Williams’s modified model for the poultry raising wastewater, it is recommended the use of equations that would determine the head loss in clean water in dimensioning the hydraulic systems that occasionally transport the poultry wastewater that have the characteristics determined in the current study. / Dissertação importada do Alexandria
2

Caracterização e avaliação de fitas porosas para irrigação localizada subsuperficial / Characterization and porous tapes evaluation for irrigation located subsurface

Alvino, Francisco Cássio Gomes 19 July 2016 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-05-31T11:34:44Z No. of bitstreams: 1 texto completo.pdf: 818950 bytes, checksum: 4ad61f137414ba93c062344989a2fce1 (MD5) / Made available in DSpace on 2017-05-31T11:34:44Z (GMT). No. of bitstreams: 1 texto completo.pdf: 818950 bytes, checksum: 4ad61f137414ba93c062344989a2fce1 (MD5) Previous issue date: 2016-07-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A sustentabilidade da irrigação passa por grandes desafios, exigindo o desenvolvimento de novas tecnologias e técnicas de implantação de sistemas que possibilitem o uso eficiente da água, redução e controle no consumo e custo da energia e otimização do uso de mão de obra como é o caso das fitas porosas. O RDI (Irrigação por Demanda da Raiz) é uma fita porosa recém lançada no mercado mundial, sendo que sua caracterização e avaliação se tornam importantes para definir a sua viabilidade técnica e econômica nos cultivos irrigados. Em função da pouca disponibilidade de características hidráulicas é essencial o desenvolvimento de trabalhos que possam dar subsídios ao correto dimensionamento de sistemas de irrigação subsuperficial. Assim, objetivou-se neste trabalho, caracterizar o desempenho hidráulico das fitas porosas e avaliar os indicadores agronômicos de três cultivares de rúcula submetidas a diferentes lâminas de irrigação utilizando as fitas porosas RDI. O experimento foi realizado em dois ambientes, ambos em Viçosa MG, o primeiro foi no Laboratório de Hidráulica do Departamento de Engenharia Agrícola da UFV, utilizando-se calhas de PVC rígido com seis metros de comprimento onde foram instaladas uma fita porosa RDI sem cobertura de solo e no final um Pluviógrafo Irriplus P300® que registrava a lâmina total aplicada e assim a vazão real das fitas porosas. Determinou-se o Coeficiente de Uniformidade Christiansen (CUC ajustado) e o coeficiente de variação de fabricação (CVf). O segundo experimento foi conduzido em ambiente protegido não climatizado. Foram utilizadas calhas de PVC preenchidas com solo aplicando-se três diferentes lâminas de água baseada no tempo diário de funcionamento das fitas de 24, 12 e 6 horas diárias (100%, 50% e 25%) e três cultivares de rúcula (Antonnela, Folha Larga e Cultivada). A caracterização hidráulica das fitas porosas RDI em funcionamento livre apresentaram elevada desuniformidade de distribuição de água, CVf insatisfatório com grande instabilidade em seu funcionamento. Apesar das limitações na qualidade na aplicação de água, foi possível observar que a cultura da rúcula apresentou maior produtividade utilizando as fitas porosas RDI, no período de operação correspondente a 12 h dia-1. Conclui-se que não é recomendado o uso do sistema RDI nas condições atuais de desenvolvimento do produto pela excessiva variabilidade e instabilidade no funcionamento. / The sustainability of irrigation involves great challenges, requiring the development of new technologies and systems implementation techniques that enable efficient use of water, reduce and control the consumption and cost of energy and optimization of labor use as is the case porous tapes. The RDI (irrigation Demand Root) is a newly porous tape released on the world market, and its characterization and independent evaluation become important to define their technical and economic viability. Due to the limited availability of hydraulic characteristics it is essential to develop work that can give subsidies to the correct dimensioning of irrigation systems with this type of water distribution. Thus, the aim of this study was to characterize the hydraulic performance of the porous tape and evaluate the agronomic indicators of three rocket cultivars submitted to different irrigation using porous tapes RDI. The experiment was conducted in two environments, both in Viçosa MG, the first was in the Hydraulics Laboratory of DEA- UFV, using rigid PVC gutters to six meters long which were installed a porous tape RDI soilless coverage and the end a rain gauge Irriplus P300® which recorded total depth applied and so the actual flow of the porous tape. It was determined the set CUC (Christiansen Uniformity Coefficient) and manufacturing variation coefficient (CVF). In the second, the experiment was conducted in a protected environment without temperature and humidity control. PVC troughs filled with soil by applying three different water depths were used based on the daily operating time of the tapes 24, 12 and 6 hours a day (100%, 50% and 25%), three rocket cultivars (Antonnela, Folha Larga and Cultivada). Hydraulic characterization of porous tapes RDI freewheel feature high uniformity of water distribution, poor CVF for this type of system, with great instability in its operation. Despite the limitations in the quality in the application of water, it was observed that the culture of the rocket showed higher productivity using the porous tape RDI in period of 12 h / day operation (50%). It is concluded that the use of the RDI system in the current conditions of product development by excessive variability and instability in operation is not recommended.

Page generated in 0.0627 seconds