• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação de técnicas de alta resolução para caracterização geoambiental de áreas com ocorrência de gás metano / Application of high resolution techniques for geoenvironmental characterization of sites with methane gas occurrence

Freitas, Leandro Gomes de [UNESP] 24 March 2017 (has links)
Submitted by LEANDRO GOMES DE FREITAS (legfreitas_br@yahoo.com.br) on 2017-05-16T03:49:19Z No. of bitstreams: 1 FREITAS,L.G._MESTRADO_HRSC_CH4.pdf: 28183033 bytes, checksum: 7752fe6e8f1336ebae2d7abc6db48c10 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-05-16T14:56:51Z (GMT) No. of bitstreams: 1 freitas_lg_me_rcla.pdf: 28183033 bytes, checksum: 7752fe6e8f1336ebae2d7abc6db48c10 (MD5) / Made available in DSpace on 2017-05-16T14:56:51Z (GMT). No. of bitstreams: 1 freitas_lg_me_rcla.pdf: 28183033 bytes, checksum: 7752fe6e8f1336ebae2d7abc6db48c10 (MD5) Previous issue date: 2017-03-24 / Os riscos associados à intrusão de gases e vapores do solo em edificações estão ganhando crescente interesse da sociedade, principalmente pelos possíveis danos à saúde humana ou até mesmo por explosões. Na região metropolitana de São Paulo, estudos ambientais vêm relatando com frequência a ocorrência de gás metano (CH4) no subsolo, gerando preocupações sociais, políticas e econômicas. Uma forma inovadora de otimizar o diagnóstico dessas áreas e gerar Modelos Conceituais mais consistentes, se dá com a utilização de técnicas de investigação de alta resolução, como o Membrane Interface Probe (MIP). Nesse contexto, foi conduzido um estudo para avaliar o potencial do MIP, associado a outras técnicas de investigação, para o diagnóstico geoambiental de uma área com a ocorrência de gás metano no subsolo. A área de estudo foi o campus da USP Leste, no município de São Paulo. O estudo foi realizado em três etapas. Na primeira, foram realizados testes de bancada para a obtenção de curvas de resposta do detector de ionização por chama (FID) do sistema MIP para diferentes misturas gasosas, com diferentes temperaturas de aquecimento da sonda. Na segunda etapa foram realizados os ensaios de campo com o MIP e com as seguintes técnicas auxiliares: Soil Color Optical Screening Tool (SCOST); amostragem de gases do solo com o sistema Post Run Tubbing (PRT); e, amostragem de solo por sondagens direct push. Na terceira etapa foram realizadas as análises laboratoriais das amostras de solo coletadas. Os resultados obtidos foram apresentados por meio de perfis e seções representativas da área de estudo. Nos ensaios de bancada, todas as curvas de resposta mostraram alta correlação entre as respostas do FID e as concentrações de CH4 das amostras. Os perfis obtidos em campo pelo sensor de condutividade elétrica do MIP, bem como os perfis de cores obtidos pelo SCOST, apresentaram boa correlação qualitativa com as descrições litológicas e com os perfis granulométricos, auxiliando na caracterização litoestratigráfica. Os ensaios MIP confirmaram a alta sensibilidade da ferramenta para a detecção de CH4, principalmente com a sonda aquecida, possibilitando o mapeamento de acumulações de biogás no subsolo. A amostragem com o PRT confirmou a existência de concentrações de até 77% v/v de CH4 nas camadas de depósitos tecnogênicos. Já as análises de teor de matéria orgânica e fração de carbono orgânico mostraram a presença de camadas com elevado teor orgânico e alto potencial metanogênico, principalmente nas camadas de argila orgânica em meio aos sedimentos quaternários. Conclui-se que o MIP demonstra um grande potencial para a caracterização em alta resolução de áreas com ocorrência de gás metano no subsolo e que as técnicas auxiliares forneceram informações importantes para apoiar a interpretação e a validação dos resultados obtidos. / The risks associated with soil gases and vapor intrusion in buildings are gaining increasing attention in our society, mainly because of possible harm to human health or even explosions. In São Paulo Metropolitan Area, environmental studies have frequently reported methane (CH4) in the subsoil, causing social, political and economic concerns. An innovative approach to optimize site assessment for these cases and generate more consistent conceptual site models (CSM), is through the application of high resolution site characterization (HRSC) tools, as the Membrane Interface Probe (MIP). In this context, a study was carried out to evaluate the potential of the MIP, associated with other subsurface investigation techniques, for the geoenvironmental diagnosis of an area with methane gas occurrence in the subsoil. The study area was the university campus of USP Leste, at São Paulo city. The study was performed in three stages, including laboratory and field procedures. On the first one, bench tests were performed to obtain response curves of the MIP’s Flame Ionization Detector (MIP/FID) for different gas mixtures, with variable probe heating temperatures. On the second stage, MIP tests were performed in the field, with the following auxiliary techniques: Soil Color Optical Screening Tool (SCOST); soil gas sampling with the Post Run Tubbing (PRT) system; and the direct push whole core soil sampling. The third and last stage consisted of laboratory analysis of the soil samples. The results of the bench tests showed very strong correlations between the FID’s response and the CH4 concentration of the samples. The profiles obtained on the field by the MIP’s electrical conductivity sensor and by the SCOST showed good qualitative correlation with the lithological descriptions and with the granulometric profiles, supporting the lithostratigraphic characterization. The MIP/FID results confirmed its high sensitivity to CH4 detection, especially with the heated probe, enabling the mapping of biogas accumulations in the subsurface. The PRT gas sampling confirmed methane’s concentrations as high as 77% v/v in the landfill layers. The organic matter analysis showed high organic content layers with great methanogenic potential, especially in the organic clay layers of the quaternary sediments. It was concluded that MIP has a great potential for the high resolution characterization of sites with methane gas occurrence and the auxiliary techniques also provided valuable information to support the interpretation and validation of the results.
2

[en] STUDY OF HIGH RESOLUTION SITE CHARACTERIZATION TECHNOLOGIES FOR THE IMPROVEMENT OF THE CONCEPTUAL SITE MODEL - CASE STUDY: DUQUE DE CAXIAS - RJ / [pt] ESTUDO DE TECNOLOGIAS DE INVESTIGAÇÃO AMBIENTAL EM ALTA RESOLUÇÃO PARA REFINAMENTO DO MODELO CONCEITUAL - ESTUDO DE CASO: DUQUE DE CAXIAS - RJ

MARIANA GAVA MILANI 15 December 2017 (has links)
[pt] Esta dissertação apresenta os resultados de duas técnicas de investigação em alta resolução: investigação passiva de vapores do solo e investigação com o uso de Membrane Interface Probe (MIP), em uma área de interesse com contaminação por hidrocarbonetos, localizada no município de Duque de Caxias/RJ. O processo de gerenciamento ambiental iniciou-se em 2012 na área e contemplou as etapas do gerenciamento de áreas contaminadas preconizadas nas legislações vigentes. Os resultados obtidos a partir das investigações tradicionais foram insuficientes para a obtenção da compreensão dos aspectos físicos e geoquímicos necessária para o sucesso das fases de diagnóstico e, consequentemente, da remediação. Portanto, duas investigações em alta resolução foram conduzidas com o objetivo de refinar o modelo conceitual de forma a atender adequadamente a Resolução CONAMA número 420/09 e Resolução CONEMA número 44/12, permitindo ações futuras mais eficientes. A investigação passiva de vapores do solo utilizou amostradores compostos por materiais adsorventes granulares, encapsulados em uma membrana microporosa hidrofóbica e quimicamente inerte que permite a difusão dos vapores presentes no meio. Os resultados, fornecidos em massa, representam qualitativamente a presença de contaminação no subsolo. O MIP é uma ferramenta de direct push com medição em tempo real, que mapeia a presença da contaminação tanto em meios insaturados quanto saturados inconsolidados. A partir dos resultados integrados, foi possível constatar que a distribuição de VOCs em água subterrânea ocorre de forma descontínua ao longo da área, sendo possível identificar cinco hot-spots distintos e suas diferentes áreas fonte, incluindo uma região com presença de LNAPL. / [en] The sources of contaminated sites are related to several factors such as the lack of knowledge of safe procedures for handling hazardous and / or toxic substances, disrespect to these safe procedures and the occurrence of accidents or leaks during industrial processes, transportation or storage of unprocessed materials and products. In addition, contamination is usually associated with the exploration of natural resources and with the expansion of the industry and/or agrarian activities, which have happened, and are still happening, at the cost of high environmental and social risks. A contaminated site is considered a risk, since its existence can generate several problems such as damages to health, impairment of the quality of water resources, restrictions on land use and damage to public and private property, and damage to the environment. These situations, in general, involve complex risks with regard to the effects of exposure to contaminants on human health (CETESB, 2013), and may have short -, medium - or long-term effects.

Page generated in 0.2011 seconds