Spelling suggestions: "subject:"high voltage cables"" "subject:"igh voltage cables""
1 |
Environmental parameter for cable ratingsTheed, Justin Edward January 1999 (has links)
No description available.
|
2 |
Analys av fältfördelning i kabelavslut av linjära och icke linjära material : Analysis of the field distribution in cable termination by linear and nonlinear materialGabrail, Philip, Samuelsson, Sam January 2016 (has links)
I nuläget används XLPE högspänningskablar vid överföring och distribution av elkraft och har en viktig roll i elsystemet. Kraftöverföring som sker över långa sträckor kopplas vidare från en punkt till en annan och sker med hjälp av kabelavslutningar. Dessa kabelavslutningar har en del sårbarheter ”felfunktion i kabelavslut” som påverkar hela elkraftsystemet. En analys och simulering av fältfördelning i kabelavslut genomfördes genom en teoretisk-respektive praktisk del i rapporten. Den teoretiska delen av rapporten genomfördes med hjälp av FEM programmet Comsol Multiphysics. Resultaten visade att den högsta fältkoncentrationen uppstår vid isolationen av kabeln och orsakade felfunktion och sårbarheter. Vid det linjära fallet för den elektriska delen resulterade en hög permittivitet till att potentialen och det elektriska fältet minskades vilket var densamma med låg konduktivitet. För det olinjära materialet ändrade sig konduktiviteten med elektriska fältet och tiden. Temperaturen vid det linjära fallet visade att vid en hög temperatur blev materialet mer ledande och gav ett högt elektriskt fält i halvledaren. I det olinjära fallet minskades materialets ledande. Detta kunde regleras med olika tröskelvärde (Eb) vilket inte kan i det linjära fallet. Den praktiska delen genomfördes i E.ON:s laboratorium för olika typer av kabelavslutningar som testades med 33 kV. Vissa av de provade kabelavslutningarna användes för provningssyfte och andra plockades ur drift på grund av felfunktion i kabeln. Ett försök för att kontrollera fältkoncentrationen genomfördes i laboratorium och resulterade till en reducerad fältfördelning i kabelavslutning. Resultatet av den praktiska delen visade hur fältkoncentrationen fördelades i kabelavslutning och att fältfördelning ledde till sammanbrott i kabeln. / Nowadays XLPE high voltage cables are used in transmission and distribution of electrical power and has an important role in the electrical system. Power transmission that occurs over long distances is diverted from one point to another and is done with the help of cable terminations. These cable terminations have some vulnerabilities that affect the entire power system. The theoretical part of the report was carried out with the help of FEM software Comsol Multiphysics. Results showed that the highest field concentration occurs at the insulation of the cable and caused malfunction and vulnerabilities. In the linear case for the electrical part resulted a high permittivity that the potential and the electric field was reduced, which showed the same result for low conductivity. For the nonlinear material the conductivity changes with the electric field and time. The temperature of the linear case showed that at high temperatures the material became more conductive. In the nonlinear case the conductive material was reduced. This could be controlled with different threshold value (Eb) which cannot in the linear case. The practical part was done in E.ON:s laboratory for different type of cable terminations that were tested with 33kV. Some of the tested cable terminations were used for testing purposes and was picked out of operation because of a malfunction in the cable. An attempt to control field concentration was carried out in the laboratory and resulted to a reduced field istribution in the cable termination. The result of the practical part showed how the field concentration was distributed in the cable termination and that the field distribution led to the collapse of the cable. / <p>QC 20160718</p>
|
3 |
Návrh provedení plošné kabelizace venkovních vedení 22 kV určené uzlové oblasti / Technical design of extensive replacement of overhead lines by HV cables in given distribution areaBracek, David January 2020 (has links)
This diploma thesis deals with the technical design of extensive replacement of overhead lines by high voltage cables in the given distribution area. In its first part the thesis is focused on the survey of the concerning legislation and technical standards, which must be followed during making technical design documentation. It also mentions the processes which precede the replacement itself. There are also the operational differences between the overhead lines and the high voltage cables in the first part, too. The second part is focused on the technical description of the given area, the technical design of the replacement by high voltage cables and the realization of calculation, which is important as a base for further realization of technical arrangements. The consideration of technical feasibility and economic efficiency are also contained in the second part.
|
Page generated in 0.0411 seconds