• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Bond of glass fibre reinforced polymer bars in high strength concrete

Saleh, Najia M. January 2018 (has links)
Very limited research studies have been conducted to examine bond of glass fibre reinforced polymer (GFRP) bars with high concrete strength. The current research project aims to compare between bond measured from a pull-out test and a hinged beam test for GFRP bars embedded in high strength concrete. Different parameters influencing bond such as GFRP bar diameter, embedment length and surface configuration were investigated in both test methods, while the bar position, i.e. top or bottom, was only studied in hinged beams. Seventy-two pull-out cubes, eight pull-out prisms and twenty-four hinged beams reinforced with GFRP bars were constructed and tested to failure. Twelve pull-out cubes and four hinged beams reinforced with steel bars were also tested for comparison purposes. The results showed that bond stress – slip curves obtained from various testing methods were similar, consisting of high initial stiffness, followed by nonlinear ascending and softening branches. In addition, it was found that the experimental bond strength obtained from hinged beams was higher than both bond strengths measured by the pull-out cube and pull-out prism. However, when a finite element analysis was conducted for hinged beams, it was shown that the tensile force in the reinforcing bar estimated by equilibrium conditions is overestimated as the large deformation of hinged beams at failure was not considered. Therefore, if the tensile force obtained from the finite element analysis is used to calculate the bond strength, it would be similar to that obtained from pull-out cube and prism. Moreover, it was found that the distribution of tensile and bond stresses was nonlinear along the GFRP embedment length and bond stress at the vicinity of the free end increased with increasing the load due to redistribution of bond stresses along the embedment length. Bond strengths were compared against the prediction methods provided in ACI-440.1R, CSA-S806, CSA-S6 and JSCE 1997. In general, all design codes showed conservative results for all specimens tested and ACI predictions gave a good agreement with experimental data compared to other codes. Artificial neural network models were developed to predict bond strength of GFRP bars in concrete. These models used bar diameter, embedment length, concrete compressive strength and concrete cover as input variables. The developed ANN models showed to be able to predict bond strength of GFRP bars in concrete and, therefore, were used to conduct a parametric study. / Higher Education Institute, Government of Libya
2

Experimental investigation of bond behaviour of two common GFRP bar types in high-strength concrete

Saleh, N., Ashour, Ashraf, Lam, Dennis, Sheehan, Therese 07 January 2019 (has links)
Yes / Although several research studies have been conducted on investigating the bond stress – slip behaviour of Glass-Fibre Reinforced Polymer (GFRP) bars embedded in high strength concrete (HSC) using a pull-out method, there is no published work on the bond behaviour of GFRP bars embedded in high strength concrete using a hinged beam. This paper presents the experimental work consisted of testing 28 hinged beams prepared according to RILEM specifications. The investigation of bond performance of GFRP bars in HSC was carried out by analysing the effect of the following parameters: bar diameter (9.5, 12.7 and 15.9 mm), embedment length (5 and 10 times bar diameter), surface configuration (helical wrapping with slight sand coating (HW-SC) and sand coating (SC)) and bar location (top and bottom). Four hinged beams reinforced with 16 mm steel bar were also tested for comparison purposes. The majority of beam specimens failed by pull-out. Visual inspection of the test specimens showed that the bond failure of GFRP (HW-SC) bars usually occurred owing to the bar surface damage, while the bond failure of GFRP (SC) bars was caused due to the detachment of sand coating. The GFRP bars with helical wrapping and sand coated surface configurations showed different bond behaviour and it was found that the bond performance of the sand coated surface was better than that of the helically wrapped surface. Bond strength reduced as the embedment length and bar diameter increased. It was also observed that the bond strength for the bottom bars was higher than that of the top bars. The bond strength was compared against the prediction methods given in ACI-440.1R, CSA-S806 and CSA-S6 codes. All design guidelines underestimated the bond strength of both GFRP re-bars embedded in high strength concrete. / Ministry of Higher Education in Libya for funding.

Page generated in 0.0824 seconds