• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Behaviour of interlocking mortarless hollow block walls under in-plane loading

Safiee, N.A., Nasir, N.A.M., Ashour, Ashraf, Bakar, N.A. 31 January 2018 (has links)
Yes / Experimental study of five full scale masonry wall panels subjected to prescibed pre-compressive vertical loading and increasing in-plane lateral loading is discussed. All five walls were constructed using interlocking mortarless load bearing hollow concrete blocks. The behaviour of wall in term of deflections along the wall height, shear strength, mortarless joint behaviour and local and overall failures under increasing in-plane lateral loading and pre-compressive vertical loading are reported and analysed. Simple strut-and-tie models are also developed to estimate the ultimate in-plane lateral capacity of the panel walls tested. The results indicate that, as the pre-compressive load increases, the in-plane lateral load capacity of walls increases. All walls tested failed due to diagonal shear and/or moderate toe crushing depending on the level of the pre-compressive load. The proposed strut-and-tie models were able to give reasonable predictions of the walls tested.
2

FATOR DE EFICIÊNCIA DA RESISTÊNCIA PRISMA/BLOCO CERÂMICO DE PAREDES VAZADAS / STRENGHT EFFICIENCY FACTOR FOR CERAMIC HOLLOW BLOCKS MASONRY PRISMS

Portella, Rafael Pires 22 January 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The Brazilian civil construction showed in the last few years a large increase in technology, thus increasing the competitiveness in the labor market. In order to remain in compliance with the standard requirements, builders need to improve, both in workmanship as in materials used questions. The masonry had an important growth in the last few years, thus increasing the need to develop studies and constantly improve the National Standards. The compressive strength is the most important factor in structural masonry, than a study and deep knowledge of the subject is necessary for designers can accomplish the projects in the best possible manner. For the use of ceramic block, NBR 15812-1 recommends that the efficiency factor walls/prism that must be used is 0,70, but there is no standardized value for the efficiency factor prism/block, leaving only to designer the choice of this value. For the project to be well specified, with the components selected as best as possible, the efficiency factor prism block have decisive role, as thought the designer calculate the prism designer strength, he must specify the mean compressive strength of mortar as the characteristic compressive strength of blocks and, if necessary, grout. With the aid of the Building Construction Material Laboratory of the Federal University of Santa Maria, which provided its tests results of the years 2007 to 2014, a study was conducted to calculate the efficiency factor of prism/block in different strength ranges of the blocks. Following this study, analyzes were made to try to predict behavior of efficiency factor due to the compressive strength of the block and be able to get a usual value for the conditions of the tested components. Only ceramic hollow blocks with no grout were approached in this study because they were in a large amount, providing greater reliability to the results. / A Construção Civil no Brasil apresentou nos últimos anos um grande aumento na área tecnológica, aumentando com isso a competitividade no mercado de trabalho. Para poderem se manter atuais e cumprindo com os requisitos de normas, as empresas da área da construção necessitam se aprimorar, tanto no quesito mão de obra como no quesito dos materiais utilizados. O método construtivo de alvenaria estrutural obteve um crescimento muito importante nos últimos anos, aumentando assim a necessidade de se desenvolver estudos e melhorar cada vez mais as normas que regem tal método. A resistência à compressão é o fator mais importante na alvenaria estrutural, logo um estudo e conhecimento aprofundado do tema se faz necessário para os projetistas poderem conseguir realizar os projetos da melhor maneira possível. Para a utilização de blocos cerâmicos, a NBR 15812-1 preconiza que o fator de eficiência parede/prisma que se deve utilizar é de 0,70, porém, não existe um valor normatizado para o fator de eficiência prisma/bloco, deixando apenas para o projetista a escolha desse valor. Para o projeto ser bem especificado, com os componentes escolhidos da maneira mais condizente com o cenário, o fator de eficiência prisma/bloco têm função determinante, visto que apesar de o projetista calcular a resistência de projeto do prisma, ele precisa especificar a resistência à compressão média da argamassa como a resistência característica à compressão de blocos e, quando necessário, grautes. Com a ajuda do Laboratório de Materiais de Construção Civil da Universidade Federal de Santa Maria, que disponibilizou os seus ensaios dos anos de 2007 até 2014, foi realizado um estudo para se calcular o fator de eficiência/prisma bloco em diferentes faixas de resistência dos blocos. Após este estudo, foram feitas análises para tentar prever o comportamento do fator de eficiência frente à resistência à compressão dos blocos e poder se chegar em um valor usual para as condições dos componentes ensaiados. Apenas blocos cerâmicos de parede vazada e não grauteados foram abordados no estudo pois eram em uma quantidade maior, fornecendo uma maior confiabilidade aos resultados obtidos.
3

Estudo de misturas solo cimento agregado reciclado de telhas cerâmicas para fabricação de blocos para alvenaria / Study of soil-cement recycled aggregate of ceramic tiles for the manufacture of masonry blocks

Silva, Blaine Alves da 24 April 2015 (has links)
This work aimed to study the incorporation of ceramic residues of tiles crushed in the soilcement mixture in the manufacture of hollow blocks, justified by the amount of these wastes generated by the ceramic tile industry, with potential for recycling. This study aimed to determine a molding energy in laboratory compatible with that of the hydraulic presses of the factory. The DNER-ME 258:1994 test method compacted soils miniature equipment Mini-MCV were used , observing that it is possible to mold bodies of proof in laboratory with ASDM apparent specific dry mass compatible with that of the hollow blocks produced in the factory. Four lots of soil-cement hollow blocks were produced, whose tests allowed to choose the most appropriate mixture, the desired value of ASDM and the number of compatible blows. The ASDM of soil-cement bodies and the blocks were compared, and there was compatibility of values. To study mixtures with the RTA Recycled Tile Aggregate the optimization methodology of the volumes of materials was used in order to fill the gaps in the aggregate with compacted soil-cement. Starting from the gap indices of the aggregate containing cement and the pure aggregate the work began with two soil-cement aggregate mixtures. By projection, other mixtures resulted from these, which, after tests, allowed to select the most adequate. Using this one, hollow blocks were manufactured, whose test results met the standard with regard to strength, but not to water absorption. To reduce the absorption, a waterproofing additive, a stabilizer and an Aloe Vera extract were inserted in the mixture, whose bodies of proof tests registered values within the normative limits in 2 cases. Hollow blocks using the most favorable mix amount were produced, whose tests attended the strength requirements, but not the absorption ones. The results obtained indicate the feasibility of the methods, and that RTA can be used for manufacturing hollow blocks, although this depends on the pressing capability of the factory. / Esta pesquisa objetivou estudar a incorporação de resíduos de telhas cerâmicas britados na mistura solo cimento, para fabricação de blocos vazados, justificada pela quantidade desses resíduos gerados pelas indústrias de telhas cerâmicas, com potencial para reciclagem. Neste estudo procurou-se estabelecer uma energia de moldagem em laboratório compatível com a das prensas hidráulicas da fábrica. Utilizou-se o método de ensaio DNER-ME 258:1994 Solos compactados em equipamento miniatura Mini-MCV, observando-se que é possível moldar em laboratório corpos de prova com MEAS - massa específica aparente seca compatível com a dos blocos vazados produzidos na fábrica. Produziu-se 4 lotes de blocos vazados de solo cimento, cujos ensaios permitiram escolher a mistura mais adequada, o valor desejado da MEAS e o número de golpes compatível. Comparou-se as MEAS dos corpos de prova e dos blocos de solo cimento, houve compatibilidade de valores. Para o estudo das misturas com o ART - agregado reciclado de telha utilizou-se a metodologia de otimização dos volumes dos materiais, de forma a preencher os vazios do agregado com solo cimento compactado. A partir dos índices de vazios do agregado com cimento e do agregado puro iniciou-se o trabalho com duas misturas solo cimento agregado. Destas, por projeção resultaram outras misturas, que após ensaios permitiu selecionar a mais adequada. Com esta, fabricou-se blocos vazados cujos resultados dos ensaios atenderam a norma quanto à resistência, mas não quanto à absorção de água. Para reduzir a absorção, inseriu-se na mistura, aditivo impermeabilizante, estabilizante e extrato de Aloe vera, cujos ensaios dos corpos de prova acusaram valores dentro dos limites normativos para 2 casos. Produziu-se blocos vazados com a dosagem mais favorável, que ensaiados, atenderam aos requisitos de resistência, mas não de absorção. Os resultados obtidos indicam a viabilidade dos métodos e que o ART pode ser utilizado na fabricação de blocos vazados, mas depende da capacidade de prensagem da fábrica. / Mestre em Engenharia Mecânica
4

Sportovně relaxační centrum / The sports and recreation center

Píšek, Pavel January 2014 (has links)
This Master´s Thesis deals with design and execution of project documentation for building of sport and wellness center. The site is situated in the outskirts of Vsetín in Zlín region. The structural system of the building is walled with porotherm blocks. Ceilings are made up of ceiling panels spiroll. Roof is mainly flat, pitched roof is only designed above squash courts. The buildings’ shape is composed of three blocks which together form a functional complex. The sport center offers these kinds of activities: spinning bike rides, exercising, weight lifting, group training and squash. The recreation centre offers massages electro and lymfo massages, pedicure, manicure, sauna, rehabilitation and solarium. Part of the center is also cafe providing also snacks, sport counseling, nutrition counseling and office.

Page generated in 0.0328 seconds