CFD modelling of a hollow fibre system for CO2 capture by aqueous amine solutions of MEA, DEA and MDEAGilassi, S., Rahmanian, Nejat 11 April 2014 (has links)
Yes / A mass transfer model was developed for CO2 capture from a binary gas mixture of N2/CO2 in hollow fibre membrane contactors under laminar flow conditions. The axial and radial diffusions through membrane and convection in tube and shell sides with chemical reaction were investigated. COMSOL software was used to numerically solve a system of non-linear equations with boundary conditions by use of the finite element method. Three different amine solutions of monoethanolamine (MEA), diethanolamine (DEA) and n-methyldiethanolamine (MDEA) were chosen as absorbent in lumen to consider the mass transfer rate of CO2 and compare their removal efficiency. The modelling results were compared with experimental data available in the literature and a good agreement was observed. The CFD results revealed that MEA had the best performance for CO2 removal as compared to DEA and MDEA under various operating conditions due to the different CO2 loading factor of absorbents. Furthermore, efficiency of CO2 removal was highly dependent on the absorbent concentration and its flow rate, increasing of the gas flow rate caused a reduction in gas residence time in the shell and consequently declined CO2 mass transfer. The modelling results showed the influence of the absorbent concentration on the CO2 mass transfer has improved due to availability of absorbent reactants at the gas-liquid interface.
|
2 |
Glucose diffusivity in tissue engineering membranes and scaffolds : implications for hollow fibre membrane bioreactorSuhaimi, Hazwani January 2015 (has links)
Unlike thin tissues (e.g., skin) which has been successfully grown, growing thick tissues (e.g., bone and muscle) still exhibit certain limitations due to lack of nutrients (e.g., glucose and oxygen) feeding on cells in extracapillary space (ECS) region, or also known as scaffold in an in vitro static culture. The transport of glucose and oxygen into the cells is depended solely on diffusion process which results in a condition where the cells are deprived of adequate glucose and oxygen supply. This condition is termed as hypoxia and leads to premature cell death. Hollow fibre membrane bioreactors (HFMBs) which operate under perfusive cell culture conditions, have been attempted to reduce the diffusion limitation problem. However, direct sampling of glucose and oxygen is almost impossible; hence noninvasive methods (e.g., mathematical models) have been developed in the past. These models have defined that the glucose diffusivity in cell culture medium (CCM) is similar to the diffusivity in water; thus, they do not represent precisely the nutrient transport processes occurring inside the HFMB. In this research, we define glucose as our nutrient specie due to its limited published information with regard to its diffusivity values, especially one that corresponds to cell/tissue engineering (TE) experiments. A series of well-defined diffusion experiments are carried out with TE materials of varying pore size and shapes imbibed in water and CCM, namely, cellulose nitrate (CN) membrane, polyvinylidene fluoride (PVDF) membrane, poly(L-lactide) (PLLA) scaffold, poly(caprolactone) (PCL) scaffold and collagen scaffold. A diffusion cell is constructed to study the diffusion of glucose across these materials. The glucose diffusion across cell-free membranes and scaffolds is investigated first where pore size distribution, porosity and tortuosity are determined and correlated to the effective diffusivity. As expected, the effective diffusivity increases correspondingly with the pore size of the materials. We also observe that the effective glucose diffusivity through the pores of these materials in CCM is smaller than in water. Next, we seeded human osteoblast cells (HOSTE85) on the scaffolds for a culture period of up to 3 weeks. Similar to the first series of the diffusion experiments, we have attempted to determine the effective glucose diffusivity through the pores of the scaffolds where cells have grown at 37°C. The results show that cell growth changes the morphological structure of the scaffolds, reducing the effective pore space which leads to reduced effective diffusivity. In addition, the self-diffusion of glucose in CCM and water has also been determined using a diaphragm cell method (DCM). The results have shown that the glucose diffusivity in CCM has significantly reduced in comparison to the water diffusivity which is due to the larger dynamic viscosity of CCM. The presence of other components and difference in fluid properties of CCM may also contribute to the decrease. We finally employ our experimentally deduced effective diffusivity and self-diffusivity values into a mathematical model based on the Krogh cylinder assumption. The glucose concentration is predicted to be the lowest near the bioreactor outlet, or in the scaffold region, hence this region becomes a location of interest. The governing transport equations are non-dimensionalised and solved numerically. The results shown offer an insight into pointing out the important parameters that should be considered when one wishes to develop and optimise the HFMB design.
|
3 |
Le développement et la modélisation numérique d'un bioréacteur pour l'ingénierie des tissus de grande masse / Development and numerical modeling of bioreactor system for the engineering of large-scale tissueMohebbi-Kalhori, Davod January 2008 (has links)
This present thesis comprise two major parts both experimental and numerical study which have been conducted in four distinct steps as following: (1) Design, construction, and evaluation of control and hydrodynamic of a bioreactor system. (2) Visualization of fluid flow perfusion in the hollow fibre membrane bioreactor (HFMB) using a biomedical noninvasive imaging technique, i.e. positron emission tomography (PET). (3) Development of a mathematical model for analyzing a hybrid hollow fibre membrane bioreactor (hHFMB) and (4) Development of a dynamic and two-porous media model for analyzing the HFMB with the aid of computational fluid dynamics (CFD), specifically for bone tissue engineering application. The experimental part includes the steps 1 and 2. In the step 1, the flow perfusion bioreactor system has been designed and constructed. The experimental evaluations of hydrodynamic, and control were performed. In this system, mean pressure, mean flow rate, frequency and waveform of the pulsatile pressure and flow rate can be modulated and controlled over the time to simulate both physiological and non-physiological conditions. The temperature, dissolved oxygen, and pH can be controlled.This bioreactor system can be applied to a variety of scaffold configurations, geometries, and sizes as the cell/tissue culture chamber is adjustable in length.This system is autoclavable, and compatible with noninvasive medical imaging techniques. Designing of the inlet and outlet manifold of the bioreactor were performed according to data obtained from CFD simulation of the flow distribution to achieve high efficiencies in the uniformity of flow perfusion. In the second step, PET was proposed for the very first time and a small animal PET system was used to obtain new information about steady and pulsatile flow patterns in the HFMB for tissue engineering applications. The non-homogeneous tracer distribution, as found with PET imaging, implies the occurrence of non-efficient regions with respect to mass transfer. In steady inlet flow condition, a non-uniform distribution of radioactive tracer was obtained. In contrast, the pulsatile inlet flow generated more uniform perfusion than that of steady flow. Further, it was found that in the case of pulsatile flow, the accumulation of the tracer within the bioreactor was efficiently less than that of steady inlet flow at the same condition. Therefore, in one hand these findings have the potential to improve bioreactor design and in the other hand can explore a very important rout to employ PET in developing bioreactors for tissue engineering applications. The numerical part includes the step 3 and 4 in which the numerical study has been performed for 3-D bone tissue growth in HFMB as a case study for large-scale tissue culture. In the step 3, the feasibility of utilizing newly proposed hHFMB for the growth of mesenchymal stem cells (MSCs) to form bone tissue was investigated using numerical simulations. To this aim, a mathematical model using a CFD code was developed to optimize the design and operation parameters of hHFMB for the growth of MSCs. The volume averaging method was used to formulate mass balance for the nutrients and the cells in the porous extracapillary space (ECS) of the hHFMB. The cell-scaffold construct in the ECS of the hollow fibres and membrane wall were treated as porous medium. Cell volume fraction dependent porosity, permeability, and diffusivity of mass were used in the model. The simulations allowed the simultaneous prediction of nutrient distribution and nutrient-dependent cell volume fraction. In addition, this model was used to study the effects of the operating and design parameters on the nutrient distribution and cell growth within the bioreactor. The modeling results demonstrated that the fluid dynamics within the ECS and transport properties and uptake rates in hHFMB were sufficient to support MSCs required for clinical-scale bone tissue growth in vitro and enabled to solve nutrition difficulties because of high cell density and scaffold size. In the step 4, the new dynamic and two-porous media model has been used for analyzing the nutrient-dependent MSCs growth in order to form the bone tissue in the HFMB. In the present model, hollow fibre scaffold within the bioreactor was treated as a porous domain. The domain consists of the porous lumen region available for fluid flow and the porous ECS region, filled with collagen gel containing cells, for growing tissue mass. Furthermore, the contributions of several design and process parameters, which enhance the performance of the bioreactor, were studied. In addition, the dynamic evaluation of cell growth, oxygen and glucose distributions were quantitatively analyzed. The obtained information can be used for better designing of the bioreactor, determining of suitable operational conditions and scale up of the bioreactor for engineering of clinical-scale bone tissue.--Résumé abrégé par UMI.
|
4 |
Investigating the influence of fabrication parameters on the diameter and mechanical properties of polysulfone ultrafiltration hollow-fibre membranesRugbani, Ali 12 1900 (has links)
Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2009. / ENGLISH ABSTRACT: Polysulfone hollow-fibre membranes were fabricated via the dry-wet solution
spinning technique. The objective was to demonstrate the influence of the various
fabrication parameters on the diameter and mechanical properties of the hollow-fibre
membranes and to optimize the spinning process by controlling these parameters with
a computer control system. The effects of the operation parameters were investigated
using an experimental design based on a fractional factorial method (Taguchi’s design
of experiments). The parameters that were considered are the spinneret size, dope
solution temperature, bore fluid temperature, coagulation bath temperature, dope
extrusion rate, bore flow rate and the take-up speed. A new pilot solution spinning
plant was installed and upgraded, and a computer control system, based on LabView,
was developed to control, monitor and log the experimental data. The diameter of the
hollow-fibres were determined using a scanning electron microscope (SEM) while the
mechanical properties were measured using a tensile tester. The effects of diameter
size and wall thickness of the hollow-fibres on the performance of the membranes
were studied.
The results showed the significance of the fabrication parameters that dominate the
diameter and strength of the hollow-fibres. / AFRIKAANSE OPSOMMING: Polisulfoon holvesel membrane is met ‘n droë-nat oplossingspin proses vervaardig.
Die doel hiermee was om die invloed van verskeie vervaardigingsparameters op die
deursnee en meganiese eienskappe van die holvesel membrane te demonstreer asook
om die spin proses te optimeer deur gerekenariseerde beheer van die aanleg. ‘n
Eksperimentele ontwerp, gebaseer op ‘n gedeeltelike faktoriaal metode (Taguchi se
eksperimentele ontwerp) is gebruik om die invloed van die vervaardigingsparameters
te ondersoek. Die parameters wat oorweeg is, is spindop grootte, materiaal
temperatuur, boorvloeistof temperatuur, stolbad temperatuur, materiaal ekstrusie
tempo and opwen spoed. ‘n Nuwe oplossingspin loodsaanleg was geïnstalleer en
opgegradeer en ‘n rekenaar beheerstelsel, gebaseer op LabView, is ontwikkel om die
aanleg te beheer, moniteer en eksperimentele data te stoor. Die deursnee van die
holvesel is gemeet met ‘n skanderingelektron mikroskoop (SEM) terwyl die
meganiese eienskappe bepaal is met ‘n trektoets apparaat. Die effek van die deursnee
en wanddikte van die holvesels op die werkverrigting van die membrane is ook
bestudeer.
Die resultate toon watter vervaardigingsparameters is beduidend vir die deursnee en
sterkte van die holvesels.
|
5 |
Intensificación del proceso de absorción de dióxido de azufre mediante contacto no dispersivo y líquidos iónicos.Luis Alconero, Patricia 06 July 2009 (has links)
La intensificación de procesos consiste en el desarrollo de equipos y técnicas innovadoras que ofrecen mejoras sustanciales en el proceso, principalmente mediante la disminución del volumen del equipo, consumo de energía o generación de residuos, dando lugar a tecnologías más baratas, seguras y sostenibles. Esta tesis enfatiza la intensificación de procesos como estrategia en la recuperación de dióxido de azufre mediante el empleo de la tecnología de membranas y de líquidos iónicos como absorbente con objeto de eliminar las pérdidas de disolvente.La intensificación del proceso se lleva a cabo en dos etapas:i) Sustitución del equipo convencional (e.g. scrubbers) por un sistema de membranas para eliminar el arrastre de gotas y,ii) Sustitución del disolvente de absorción (N,N-dimetilanilina) por líquidos iónicos para eliminar pérdidas de disolvente por su volatilización en la corriente de gas debido a su presión de vapor despreciable. La selección de un líquido iónico adecuado se basa en su afinidad hacia dióxido de azufre, baja viscosidad, bajo coste y baja ecotoxicidad.En resumen, esta tesis es el primer trabajo que combina el empleo de un contactor de membranas de fibra hueca con líquidos iónicos, contribuyendo al desarrollo de procedimientos innovadores para intensificar el proceso de absorción de dióxido de azufre. / Process intensification consists of the development of innovative devices and techniques that offer significant improvements in chemical manufacturing and processing, decreasing substantially equipment volume, energy consumption, or wastes, and ultimately leading to cheaper, safer and sustainable technologies. This thesis emphasizes the process intensification as the strategy to the recovery of sulfur dioxide, according to the material efficiency and environmental protection, by means of technology based on membranes and ionic liquids as absorption solvents in order to avoid solvent losses.Process intensification is performed in two steps:i) Substitution of conventional equipment (e.g. scrubbers) for a membrane device to avoid drops dragging and,ii) Substitution of the absorption solvent (N,N-dimethylaniline) for ionic liquids to avoid solvent losses due to volatilization of solvent into the gas stream because of their negligible vapor pressure. Selection of a suitable ionic liquid is based on its affinity towards sulfur dioxide, low viscosity, low cost and low ecotoxicity.Thus, this thesis is the first work that combines a hollow fibre membrane contactor and ionic liquids, contributing to the development of innovative procedures to intensify the sulfur dioxide absorption process.
|