• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeitos da interferencia eletromagnetica conduzida em equipamentos eletromedicos no ambiente hospitalar

Zevzikovas, Marcos 03 August 2018 (has links)
Orientador : Sergio Santos Muhlen / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-03T22:15:42Z (GMT). No. of bitstreams: 1 Zevzikovas_Marcos_M.pdf: 2277931 bytes, checksum: d647f35ad6f338ef8fa869b5cad0b316 (MD5) Previous issue date: 2004 / Mestrado
2

Metodologia de priorização de equipamentos medico-hospitalares em programas de manutenção preventiva

Oliveira, Vivian Cardoso de Morais, 1977- 27 February 2004 (has links)
Orientador : Sergio Santos Muhlen / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-30T17:05:29Z (GMT). No. of bitstreams: 1 Morais_VivianCardosode_M.pdf: 1573535 bytes, checksum: a6d1d75b01d064561f346c98785fbcf5 (MD5) Previous issue date: 2004 / Resumo: A segurança de pacientes e usuários, a qualidade no atendimento e a maior disponibilidade dos equipamentos médicos são objetivos e preocupações constantes em estabelecimentos assistenciais de saúde (EAS). Programas de manutenção preventiva contribuem para alcançar estas metas, mas a inclusão indiscriminada de todos os equipamentos toma-se inviável financeiramente para a instituição de saúde. É necessário, portanto, desenvolver uma metodologia que estabeleça a prioridade para a inclusão dos equipamentos em tais programas. Por isso, há alguns anos diversos autores (Hertz, 1990; Anderson, 1992; Kendall et aI., 1993; Gullikson, 1995; Capuano & Koritko, 1996; Wang, 2000 entre outros) vêm se dedicando ao estudo e desenvolvimento de critérios de priorização de equipamentos em hospitais norte americanos. Um dos primeiros métodos publicados, e também o mais citado na literatura é o de Fennigkoh & Smith (1989), que atribui valores quantitativos aos seguintes fatores: risco, função do equipamento e recomendações de manutenção. No entanto, a simples aplicação desses parâmetros nos hospitais brasileiros pode levar a inclusões ou exclusões inadequadas devido às diferenças culturais existentes entre a engenharia clínica no Brasil e nos EUA já observadas por diversos autores nacionais (Martins et aI., 1990; Ramírez & Calil, 1996; Lucatelli, 1998). Nesse sentido, é necessário definir outros parâmetros que permitam o refinamento da metodologia de priorização, adaptando-a as necessidades dos hospitais brasileiros. Este trabalho reavalia os critérios até agora utilizados e propõe novos critérios, focalizando a importância do equipamento dentro da missão global das EAS (Wang, 2000). Critérios como: taxa de utilização do. equipamento; taxa de falhas; mantenabilidade; custos da manutenção; importância do equipamento na missão da instituição, e outros; além dos clássicos já mencionados, serão incluídos em um fluxograma de decisões de periodicidade. Pretende-se com isto determinar intervalos de MP que considerem a realidade brasileira e resultem em uma priorização mais adequada para cada equipamento / Abstract: The safety of patients and users, the quality in the service and a higher availability of medical equipment are goals and constant worries in health institutions. Programs of preventive maintenance contribute to achieve these targets, but the inclusion of all equipment becomes financially not viable for the institution. 50 it is necessary to develop a way establishing the priority for inclusion of equipments in as such programs. Many authors (Hertz, 1990; Anderson, 1992; Kendall et aI., 1993; Gullikson, 1995; Capuano & Koritko, 1996; Wang, 2000 among others) have developed criteria of priority for equipments in American hospitals. The first approach published, and also the most cited in the literature, is Fennigkoh & Smith's inclusion criteria (1989); this criteria attributed quantitative values to the following factors: risk, function of the equipment and recommendations for maintenance. However, the application of those parameters in Brazilian hospitals can cause an inadequate equipment inclusion or exclusions due to cultural differences between the clinical engineering practices in Brazil and in the USA. This was already observed by several Brazilian authors (Martins et aI., 1990; Ramírez & Calil, 1996; Lucatelli, 1998). In that sense, it is necessary to define other parameters to allow the refinement for the criteria of inclusions and to adapt it to the needs of the Brazilian hospitals. This work analyses the criteria so far utilized and suggests new ones, focusing in the importance of the equipment inside the global mission of the hospital (Wang, 2000); rate of utilization of the equipment; rate of fails; mantenability; costs with maintenance; and others; beyond the classics already mentioned. All these parameters were included in a decision flowchart, intending to determine intervals of PM that best fit in the Brazilian's reality / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
3

Metodologia para avaliação do desempenho metrológico em equipamentos médico-hospitalares

Alexandrino, Josemir da Cruz 03 1900 (has links)
Submitted by LIVIA FREITAS (livia.freitas@ufba.br) on 2015-12-03T18:56:39Z No. of bitstreams: 1 TeseJosemirAlexandrino.pdf: 4030416 bytes, checksum: 971f2eadd7c4d23fb1945b3a4dfbd1d5 (MD5) / Approved for entry into archive by LIVIA FREITAS (livia.freitas@ufba.br) on 2016-01-11T15:27:48Z (GMT) No. of bitstreams: 1 TeseJosemirAlexandrino.pdf: 4030416 bytes, checksum: 971f2eadd7c4d23fb1945b3a4dfbd1d5 (MD5) / Made available in DSpace on 2016-01-11T15:27:49Z (GMT). No. of bitstreams: 1 TeseJosemirAlexandrino.pdf: 4030416 bytes, checksum: 971f2eadd7c4d23fb1945b3a4dfbd1d5 (MD5) / O uso massivo de tecnologia na área da saúde tem elevado a efetividade dos procedimentos médicos, com consequente melhoria da qualidade de vida dos pacientes. Entretanto, tais tecnologias trazem riscos intrínsecos, que podem resultar em danos, quando mal utilizadas ou mantidas. Neste contexto, encontram-se os Equipamentos Médico-hospitalares (EMH) que podem apresentar problemas que resultem em diagnósticos errôneos, terapias inapropriadas ou que comprometam a segurança dos usuários. A avaliação periódica, e em particular, do desempenho metrológico, constitui-se em importante meio para alcançar o uso seguro do EMH. As soluções encontradas para tal avaliação são rigidamente condicionadas às especificidades de cada tipo de EMH e dificilmente podem ser aproveitadas para outros. Embora não tenha sido encontrada na literatura uma solução generalista que possa ser aplicada a determinados tipos de EMH, esta indica viabilidade de aplicação, em função dos constantes avanços tecnológicos do setor. Neste sentido, este trabalho apresenta uma metodologia para a avaliação do desempenho metrológico de EMHs e para tal, foi desenvolvido um sistema que reúne instrumentos de medição integrados a um software gerenciador de ensaios. Este software realiza a aquisição e monitoramento de dados de medição relativos às variáveis metrológicas do equipamento sob teste, avalia a adequação destes dados a requisitos metrológicos preestabelecidos e emite relatório de conformidade. O sistema permite a configuração de diversos parâmetros, possibilitando a execução de avaliações de desempenho metrológico em diferentes tipos de EMH. Para fins de validação, o sistema foi configurado para realizar avaliações em bisturis elétricos e incubadoras neonatais. Os resultados mostram a eficácia da metodologia desenvolvida e a eficiência da plataforma computacional para avaliação metrológica de EHM.

Page generated in 0.0731 seconds