• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 6
  • 1
  • 1
  • Tagged with
  • 22
  • 22
  • 13
  • 8
  • 8
  • 7
  • 6
  • 6
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Alternative solutions to 1960's single corridor ward design in hospitals : a case study based on nurses's perspectives /

Rastogi, Nandita P., January 1991 (has links)
Thesis (M.S.)--Virginia Polytechnic Institute and State University, 1991. / Vita. Abstract. Includes bibliographical references (leaves 113-120). Also available via the Internet.
2

The 48 hour patient - who reaps the rewards?

Crozier, Rosemarie. January 2008 (has links)
Thesis (M. Nurs.)--Victoria University (Melbourne, Vic.), 2008.
3

Sustaining the commitment to patient safety huddles: insights from eight acute hospital ward teams

Montague, Jane, Crosswaite, Kate, Lamming, Laura, Cracknell, A., Lovatt, A., Mohammed, Mohammed A. 01 August 2019 (has links)
Yes / A recent initiative in hospital settings is the patient safety huddle (PSH): a brief multidisciplinary meeting held to highlight patient safety issues and actions to mitigate identified risks. The authors studied eight ward teams that had sustained PSHs for over 2 years in order to identify key contributory factors. Methods: Unannounced observations of the PSH on eight acute wards in one UK hospital were undertaken. Interviews and focus groups were also conducted. These were recorded and transcribed for framework analysis. Findings: A range of factors contributes to the sustainability of the PSH including a high degree of belief and consensus in purpose, adaptability, determination, multidisciplinary team involvement, a non-judgemental space, committed leadership and consistent reward and celebration. Conclusion: The huddles studied have developed and been shaped over time through a process of trial and error, and persistence. Overall this study offers insights into the factors that contribute to this sustainability.
4

An investigation into the factors affecting underutilisation of the Phelandaba clinic labour ward by low risk pregnant women in Maputaland Northern KwaZulu-Natal

Mathenjwa, Nozipho Celia Herietta January 2005 (has links)
Thesis (M.Tech.: Nursing)-Durban Institute of Technology, 2005 1 v. : ill. ; 30 cm / An exploratory descriptive research design was used for this study which investigated the underutilisation of a rural clinic’s labour ward by low risk pregnant women (LRPW). The study took place in Maputaland, Northern KwaZulu-Natal. Rosenstock’s health belief model (HBM) modified by Becker et al, in 1977 was adapted as a framework for this study.
5

The design of isolation ward for reducing airborne infection in common clinical settings. / 臨床環境條件下隔離病房設計以減少空氣傳播感染 / CUHK electronic theses & dissertations collection / Digital dissertation consortium / Lin chuang huan jing tiao jian xia ge li bing fang she ji yi jian shao kong qi chuan bo gan ran

January 2011 (has links)
According to recommendations from the Facility Guidelines Institute (FGI) of the American Institute of Architects (AIA), World Health Organization (WHO) and Center for Disease Control and Prevention (CDC), a common engineering approach to isolation room design is to maintain the air ventilation rate at a minimum of 12 air changes per hour (ACH) for mixing and dilution, and a negative pressure in the room to direct airflow inwards, instead of leaking outwards. / In collaborations with physicians in the Respiratory Division and the Intensive Care Unit (ICU) at the Chinese University of Hong Kong (CUHK), a series of experiments were carried out to verify the ventilation performance of an All room at the Princess Margaret Hospital (PMH). Experiments investigated the effects of ACH, the control of airflow direction, the air tightness of the automatic swing door and the application of positive pressure ventilation procedures, such as high flow rate oxygen masks, jet nebulizers and NPPV. These were extensively tested in two different isolation rooms of the Prince of Wales Hospital (PWH) and PMH, under common clinical circumstances and environmental conditions. / Many patients with severe respiratory infection require supportive therapy for respiratory failure. Common interventions involve supplemental oxygen to improve tissue oxygenation. In the worst scenario, mechanical ventilation via non-invasive positive pressure ventilation (NPPV) may be required. Since a large amount of aerosols is generated during these interventions, there is a great risk of spreading infectious aerosols from the respiratory tract of the patient to the surrounding environment. / The aerodynamic data in this thesis infonns architects and engineers on how to improve the hospital ward ventilation design so as to avoid aerosol and ventilation leakage. Ultimately, it is hoped that this work may play a role in preventing devastating nosocomial outbreaks in the future. / The design of airborne infection isolation (AII) room has become one of the major research domains following the emergence of the global concern of acute respiratory diseases in this century. These include severe acute respiratory syndrome (SARS) in 2003, H5N1 avian influenza, and pandemic influenza H1N1 in 2009. All of which have claimed thousands of lives. Even with the current stringent design and practice guidelines, nosocomial infection of healthcare workers (HCWs) and inpatients continues to occur. This implies that there might be limitations in current isolation ward designs. / The experiments implemented a high-fidelity human patient simulator (HPS) which could be programmed with different lung breathing conditions and oxygen flow rate settings. The patient exhaled air dispersion distances and airflow patterns were captured in detail with a non-intrusive, laser light sheet, smoke particle scattering technique, designed for this thesis. Thin laser light sheets were generated by a high energy YAG laser with custom cylindrical optics. Smoke concentration in the patient exhaled air and leakage jets was estimated from the intensity of light scattered, which was then expressed as nonnalized particle concentration contours using computer programs developed for this study. / The study quantitatively revealed the distinctive patient exhaled airflow patterns and the extent of bioaerosol, generated directly from the patient source with the application of different oxygen delivery interventions for different patient lung conditions and oxygen flow rates. It was found that contamination was more critical during the administration of oxygen therapies, which is common in clinical circumstances. Source control is therefore the most efficient and effective approach to the reduction and even elimination of patient exhaled bioaerosol contaminants. Thus, when working in an isolation room environment, full preventive measure should be taken and it is essential to consider the location of mechanical vents and the patient exhaled airflow patterns. It has also been shown in experiment that applications of bacterial viral filter could be a solution to the problem. / Chow, Ka Ming. / Advisers: Puay Peng Ho; Jin Yeu Tsou. / Source: Dissertation Abstracts International, Volume: 73-09(E), Section: A. / Thesis (Ph.D.)--Chinese University of Hong Kong, 2011. / Includes bibliographical references (leaves 115-147). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Electronic reproduction. Ann Arbor, MI : ProQuest Information and Learning Company, [200-] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstract also in Chinese.
6

An investigation into the factors affecting underutilisation of the Phelandaba clinic labour ward by low risk pregnant women in Maputaland Northern KwaZulu-Natal

Mathenjwa, Nozipho Celia Herietta January 2005 (has links)
Thesis (M.Tech.: Nursing)-Durban Institute of Technology, 2005 1 v. : ill. ; 30 cm / An exploratory descriptive research design was used for this study which investigated the underutilisation of a rural clinic’s labour ward by low risk pregnant women (LRPW). The study took place in Maputaland, Northern KwaZulu-Natal. Rosenstock’s health belief model (HBM) modified by Becker et al, in 1977 was adapted as a framework for this study.
7

Patient satisfaction with nursing care : a comparison analysis of critical care and medical units

Singleton, Alsy R. January 1997 (has links)
Patient satisfaction is an outcome of care that represents the patient's judgment on the quality of care. An important aspect of quality affecting patient's judgment can be attributed to patients' expectations and experiences regarding nursing care according to type of unit. The purpose of this study was to examine differences between patients' perceptions of satisfaction with nursing care in critical care units and medical units in one Midwestern hospital.The conceptual framework was "A Framework of Expectation" developed by Oberst in 1984, which asserted that patients have expectations of hospitals and health care professionals regarding satisfaction and dissatisfaction with care. The instrument used to measure patient satisfaction was Risser's Patient Satisfaction Scale, with three dimensions of patient satisfaction: (a) Technical-Professional, (b) Interpersonal-Educational, (c) Interpersonal-Trusting. The convenience sample included 99 patients50 from critical care units and 49 from medical wards. Participation was voluntary. The study design was comparative descriptive and data was analyzed using a t-test.The demographic data showed that the majority of patients had five or more admission. About one-third of the patients were 45-55, 56-65, 66-75, respectively. Findings related to the research questions were that: (a) 84 percent of the respondents rated overall satisfaction in the satisfactory to excellent range, (b) results of a t-test showed significant differences in overall patient satisfaction with patients being more satisfied with care in critical care units. Significant differences were found in three subscales with critical care being more satisfied. No relationship was found between patient satisfaction and age/and/or type of unit.Conclusions were that in both medical and critical care units patients were more satisfied with Technical-Professional and Interpersonal-Trusting than with Interpersonal-Educational. Also noted was that patients in the units where nurse-to-patient ratio was higher participants perceived that nurses had more time, energy and ability to meet patient expectation. Implications call for analysis of nurse/patient ratio in relation to patient satisfaction and nurses in relation to patient education as well as patient's perceptions of getting their needs met. / School of Nursing
8

La qualité des services offerts au Centre Hospitalier St-Georges de Beauce /

Poulin, Jacynthe. January 1994 (has links)
Mémoire (M.P.M.O.)-- Université du Québec à Chicoutimi, 1994. / Résumé disponible sur Internet. CaQCU Document électronique également accessible en format PDF. CaQCU
9

Limited semi-private a study of private patients on a ward service : submitted to the Program in Hospital Administration ... in partial fulfillment ... for the degree in Master of Hospital Administration /

Neuhauser, Duncan, January 1963 (has links)
Thesis (M.H.A.)--University of Michigan, 1963.
10

Limited semi-private a study of private patients on a ward service : submitted to the Program in Hospital Administration ... in partial fulfillment ... for the degree in Master of Hospital Administration /

Neuhauser, Duncan, January 1963 (has links)
Thesis (M.H.A.)--University of Michigan, 1963.

Page generated in 0.0584 seconds