• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Glucose Sensors Based on Copper Thin Films / Facile and Flexible Glucose Sensors Based on Copper Thin Films

ALAM, MD MAKSUD January 2023 (has links)
The electrochemical enzymatic electrodes dominate the world market for blood glucose monitoring devices for controlling, as well as reducing the detrimental effects of diabetes. However, the enzymatic electrodes exhibit constraints restricting their reliance on the enzyme’s activity which can be influenced by the external, and the environmental factors such as temperature, pH, and humidity etc. However, the greater thickness of the enzyme layer hinders the performance of the glucose biosensors resulting in signal dampening or loss. In addition, the selectivity of the electrodes is affected by the interferents present in blood. Moreover, the invasive nature of the electrodes is a major problem considering the patient’s perspective. In contrast, recent research activities demonstrated that the electrochemical non-enzymatic electrodes possess huge potential for inexpensive and highly sensitive glucose monitoring devices, yet these electrodes are invasive in nature. Therefore, the purpose of this research was to fabricate electrochemical non-enzymatic non-invasive electrodes for sweat glucose monitoring devices. A very simple low-cost fabrication technique has been shown to make the facile, flexible, and inexpensive electrodes to detect sugar in sweat bio-analyte for a non-invasive glucose monitoring system using the native stable Cu oxides (CuNOx), Cu2O, layers grown on 35 µm thin Cu foils keeping under ambient conditions (25℃- and 760-mm Hg) for more than 2 years so that the oxide layers are full-grown, and fully stable. Moreover, the foils also annealed at various temperatures such as 160, 230, and 280℃ with new temperature profile for reducing the required time of growing stable oxides and producing oxides with larger crystallized structures with higher surface – to – volume ratio. The X-ray photoelectron spectroscopy (XPS) and high-resolution transmission electron microscopy (HRTEM) results supported that at 280℃ annealing temperature the surface, mostly, transformed into highly electrocatalytic CuO with larger grain sizes, crystallized structures, and the uniform layer of ~ 140 nm. The electrochemical characterization, and sensing performance of the electrodes have been done by cyclic voltammetry (CV), one of the excellent and well accepted electrochemical methods, with the 3 – electrode configuration of the potentiostat. The CuNOx sensors of having ~10 nm layer of stable Cu2O exhibited a sensitivity of 603.42 μA mM−1 cm−2, a linear range beyond the desired limit of 7.00 mM with excellent linearity (R2 = 0.9983) and a low limit of detection of 94.21 μM. In contrast, the new annealing profile has. the CuNOx sensors annealed at 280 ºC using new temperature profile provided twin calibration curves of linear ranges of 0.05 – 1.00 mM and 1.00 – 7.00 mM, that applicable for sweat and blood glucose sensing, respectively, and exhibited a sensitivity of 1795 μA mM−1 cm−2, a linear range up to the desired limit of 1.00 mM for sweat glucose sensing with excellent linearity (R2 = 0.9844), and a lower limit of detection of 135.39 μM. In addition, it has been shown that the peak electro-oxidation current of glucose sensing is linearly related with the squire root of the annealing temperature, √T. This can help to figure out the required applied annealing temperature for getting desired peak electro-oxidation current of glucose in a human health monitoring system. / Dissertation / Doctor of Philosophy (PhD)
2

Monitoramento da saúde humana através de sensores: análise de incertezas contextuais através da teoria da evidência de Dempster-Shafer. / Human health monitoring by sensors: analysis of contextual uncertainties through Dempster-Shafer evidence theory.

Silva, Kátia Cilene Neles da 26 November 2012 (has links)
O monitoramento remoto da saúde humana envolve basicamente o emprego da tecnologia de rede de sensores como meio de captura dos dados do paciente em observação e todo ambiente em que este se encontra. Esta tecnologia favorece o monitoramento remoto de pacientes com doenças cardíacas, com problemas respiratórios, com complicações pós-operatórias e ainda pessoas em tratamento residencial, dentre outros. Um importante elemento dos sistemas de monitoramento remoto da saúde é a sua capacidade de interagir com o meio no qual está inserido possibilitando-lhe, por exemplo, agir como provedor de informação e serviços relevantes para o usuário. Essa interação com o ambiente imputa a esse sistema características relacionadas com uma aplicação sensível ao contexto, pois esses sistemas reagem e se adaptam às mudanças nos ambientes, provendo-lhes assistência inteligente e proativa. Outro aspecto observado em sistemas de monitoramento remoto da saúde humana está relacionado às incertezas associadas à tecnologia empregada como meio para obtenção e tratamento dos dados e, aos dados que serão apresentados aos usuários especialistas - médicos. Entende-se que incertezas são elementos inevitáveis em qualquer aplicação ubíqua e sensível ao contexto, podendo ser geradas por dados incompletos ou imperfeitos. No âmbito do monitoramento da saúde humana, fatores como a influência mútua entre dados fisiológicos, comportamentais e ambientais também podem ser apontados como potenciais geradores de informação contextual incerta, além daqueles inerentes às aplicações ubíquas e sensíveis ao contexto. Nesta pesquisa, considera-se que cada sensor captura um tipo de dado e o envia para uma estação localizada na residência do paciente. O objetivo deste trabalho é apresentar um processo para a análise das incertezas contextuais presentes no monitoramento da saúde humana através de sensores. O processo empregado baseou-se na Teoria da Evidência de Dempster- Shafer e no Modelo de Fatores de Certeza. No processo denominado PRANINC, cada dado capturado pelos diferentes sensores é considerado uma evidência e o conjunto dessas evidências é considerado na formação das hipóteses. Três classes de incertezas contextuais foram especificadas: as incertezas provenientes da tecnologia empregada na transmissão dos dados capturados por sensores; as incertezas relacionadas aos próprios sensores, que estão sujeitos a erros e defeitos; e, as incertezas associadas à influência mútua entre as variáveis observadas. O método foi empregado a partir da realização de experimentos sobre arquivos com dados fisiológicos de pacientes reais, aos quais foram adicionados elementos comportamentais e ambientais. Como resultado, foi possível confirmar que o contexto influencia nos dados repassados pelo sistema de monitoramento, e que as incertezas contextuais podem influenciar na qualidade das informações fornecidas, devendo estas serem consideradas pelo especialista. / The remote monitoring of human health basically involves the use of sensor network technology as a means of capturing patient data and observation, in every environment. The sensor technology facilitates remote monitoring of patients with heart disease, respiratory problems, postoperative complications and even people in residential treatment. An important element of the health monitoring system is its ability to interact with the environment which allows, for example, act as a provider of relevant information and services to the user. The interaction with the environment provides to the system the characteristics related to a context-aware application, once this kind of system can react and adapt itself in face of environment´s changes, through a proactive and intelligent assistance. Another significant aspect of health monitoring systems is related to the uncertainties associated with the technology used as a means for obtaining and processing the data sensed by sensors, and the data which will be presented to the experts users - physicians. Uncertainties are inevitable elements in any ubiquitous and context-aware application and it can be generated by incomplete or imperfect data. In the human health monitoring by sensors factors, such as the mutual influence between physiological, behavioral and environmental data are mentioned as potential generators of uncertain contextual information. This research take into consideration that each sensor captures a data type and sends it to a station located in the patient\'s home. The objective of this paper is to present a process to analyze the contextual uncertainties present in the monitoring of human health via sensors. The method used was based on the Dempster-Shafer Evidence Theory and The Uncertainty Factor Model. The process named PRANINC, considers each data captured, by different sensors, as evidence and, all of the evidences are considered in the formation of hypotheses. Three contextual classes of uncertainties were specified: the uncertainties arising from the technology employed in transmitting the data captured by sensors, the uncertainties related to the actual sensors, which are subject to errors and defects, and the uncertainties associated with the mutual influence between the observed variables. The method was employed through conducting experiments on files with physiological data of real patients, to which, were added behavioral and environmental factors. As a result was possible to confirm that the context influences the data transferred by the monitoring system and that contextual uncertainties may influence the quality of the information which shall be considered by the specialist.
3

Monitoramento da saúde humana através de sensores: análise de incertezas contextuais através da teoria da evidência de Dempster-Shafer. / Human health monitoring by sensors: analysis of contextual uncertainties through Dempster-Shafer evidence theory.

Kátia Cilene Neles da Silva 26 November 2012 (has links)
O monitoramento remoto da saúde humana envolve basicamente o emprego da tecnologia de rede de sensores como meio de captura dos dados do paciente em observação e todo ambiente em que este se encontra. Esta tecnologia favorece o monitoramento remoto de pacientes com doenças cardíacas, com problemas respiratórios, com complicações pós-operatórias e ainda pessoas em tratamento residencial, dentre outros. Um importante elemento dos sistemas de monitoramento remoto da saúde é a sua capacidade de interagir com o meio no qual está inserido possibilitando-lhe, por exemplo, agir como provedor de informação e serviços relevantes para o usuário. Essa interação com o ambiente imputa a esse sistema características relacionadas com uma aplicação sensível ao contexto, pois esses sistemas reagem e se adaptam às mudanças nos ambientes, provendo-lhes assistência inteligente e proativa. Outro aspecto observado em sistemas de monitoramento remoto da saúde humana está relacionado às incertezas associadas à tecnologia empregada como meio para obtenção e tratamento dos dados e, aos dados que serão apresentados aos usuários especialistas - médicos. Entende-se que incertezas são elementos inevitáveis em qualquer aplicação ubíqua e sensível ao contexto, podendo ser geradas por dados incompletos ou imperfeitos. No âmbito do monitoramento da saúde humana, fatores como a influência mútua entre dados fisiológicos, comportamentais e ambientais também podem ser apontados como potenciais geradores de informação contextual incerta, além daqueles inerentes às aplicações ubíquas e sensíveis ao contexto. Nesta pesquisa, considera-se que cada sensor captura um tipo de dado e o envia para uma estação localizada na residência do paciente. O objetivo deste trabalho é apresentar um processo para a análise das incertezas contextuais presentes no monitoramento da saúde humana através de sensores. O processo empregado baseou-se na Teoria da Evidência de Dempster- Shafer e no Modelo de Fatores de Certeza. No processo denominado PRANINC, cada dado capturado pelos diferentes sensores é considerado uma evidência e o conjunto dessas evidências é considerado na formação das hipóteses. Três classes de incertezas contextuais foram especificadas: as incertezas provenientes da tecnologia empregada na transmissão dos dados capturados por sensores; as incertezas relacionadas aos próprios sensores, que estão sujeitos a erros e defeitos; e, as incertezas associadas à influência mútua entre as variáveis observadas. O método foi empregado a partir da realização de experimentos sobre arquivos com dados fisiológicos de pacientes reais, aos quais foram adicionados elementos comportamentais e ambientais. Como resultado, foi possível confirmar que o contexto influencia nos dados repassados pelo sistema de monitoramento, e que as incertezas contextuais podem influenciar na qualidade das informações fornecidas, devendo estas serem consideradas pelo especialista. / The remote monitoring of human health basically involves the use of sensor network technology as a means of capturing patient data and observation, in every environment. The sensor technology facilitates remote monitoring of patients with heart disease, respiratory problems, postoperative complications and even people in residential treatment. An important element of the health monitoring system is its ability to interact with the environment which allows, for example, act as a provider of relevant information and services to the user. The interaction with the environment provides to the system the characteristics related to a context-aware application, once this kind of system can react and adapt itself in face of environment´s changes, through a proactive and intelligent assistance. Another significant aspect of health monitoring systems is related to the uncertainties associated with the technology used as a means for obtaining and processing the data sensed by sensors, and the data which will be presented to the experts users - physicians. Uncertainties are inevitable elements in any ubiquitous and context-aware application and it can be generated by incomplete or imperfect data. In the human health monitoring by sensors factors, such as the mutual influence between physiological, behavioral and environmental data are mentioned as potential generators of uncertain contextual information. This research take into consideration that each sensor captures a data type and sends it to a station located in the patient\'s home. The objective of this paper is to present a process to analyze the contextual uncertainties present in the monitoring of human health via sensors. The method used was based on the Dempster-Shafer Evidence Theory and The Uncertainty Factor Model. The process named PRANINC, considers each data captured, by different sensors, as evidence and, all of the evidences are considered in the formation of hypotheses. Three contextual classes of uncertainties were specified: the uncertainties arising from the technology employed in transmitting the data captured by sensors, the uncertainties related to the actual sensors, which are subject to errors and defects, and the uncertainties associated with the mutual influence between the observed variables. The method was employed through conducting experiments on files with physiological data of real patients, to which, were added behavioral and environmental factors. As a result was possible to confirm that the context influences the data transferred by the monitoring system and that contextual uncertainties may influence the quality of the information which shall be considered by the specialist.

Page generated in 0.0691 seconds