Examination of Drying and Psychrometric Properties of High Water-Cement Ratio Concretes

McNicol, Thomas James 22 March 2016 (has links)
Moisture from concrete has been estimated to be responsible for over $1 billion annually from damages in floor coverings. To prevent damages, flooring manufacturers require installers to test concrete moisture levels to determine if the concrete has dried sufficiently to receive flooring or covering. Two of the main tests used in the United States to determine concrete moisture levels are moisture vapor emissions rate (MVER) tests and relative humidity (RH) tests. Changes in ambient temperature can affect the results of both RH and MVER tests. The goal of this study was to investigate the effects of ambient temperature changes on the RH of concrete, and compare the sensitivity of RH measurements to the results of MVER tests at the same ambient temperature. The RH of concrete was measured at 20%, 40%, 60%, and 80% of depth in each sample and tracked over a period of 24 days to develop drying curves at each depth, and drying profiles of each sample. The changes in concrete RH due to a change in ambient temperature were predicted using the psychrometric process and a model developed during this study. Due to size constraints on the concrete samples, ASTM 1869 had to be altered during the MVER tests. Typical RH change in the concrete samples was under 4% RH after either an increase or decrease in an ambient temperature of 5.5°C (10°F). The psychrometric process predicted that the concrete RH would change between 20% - 40% RH after the ambient temperature changed by 5.5°C. Psychrometric properties were not able to full describe the behavior of air in concrete pores so a new model was created to better predict the change in concrete RH after a change in ambient temperature. The developed model was able to predict concrete RH change within 5% error over the range of tested temperatures. / Master of Science
2

Case Study on Residential Humidity Control at U.S. Coast Guard Bayamon Housing

Meneses, Ivan R. 21 November 2004 (has links)
The intention of this study is to investigate the main source of unacceptable humidity levels at the U.S. Coast Guard Housing located in Bayamon, Puerto Rico. The aim of this research is to use a systematic approach to resolve the humidity and mold issues by testing the least expensive solutions first. This study involves the recording of indoor air quality conditions for six months as an analysis tool to investigate current air conditions and to document how physical changes to the air conditioning units will affect the resulting air conditions. This research will investigate and implement different approaches geared to solving the high humidity issues. Some of the most relevant changes that will be tested are the installation of heat pipe technology, the addition of fresh air to existing air conditioning units to create positive pressure, and the review of the space load design of currently installed air conditioning units to determine if the units were over-designed. In addition, this study will verify the relationship between energy-saving thermostats and high humidity, determine any connection between roof leaks and high humidity indoors, and determine the estimated cost to the Coast Guard to implement the recommended changes.