Testování jednotek Merging Unit v sestavě s proudovými a napěťovými převodníky / Testing of Merging Unit comprising voltage and current transducers in the set

Ziegler, Jiří January 2016 (has links)
The diploma thesis is focused on testing and design of a test system of merging unit which provides digital output according to IEC 61850-9-2. The parameters and distinguishing features of the test system are based on functional principles of merging unit and standards dealing with the testing of transducers. The proposed test system is based on modular PXI Express system from National Instruments. The desing is performed with respect to the possibility of generating test signals and measurements for voltage up to 38.4 kV and current up to 2000 A. The proposed test system meets the criteria for testing transducers of accuracy class up to 0.5. Assuming of calibration designed test system as a whole, this test setup has the potential to meet the technical requirements for testing transducers of accuracy class up to 0.1.
2

Systém chránění s využitím výstupu z elektronického senzorického systému měření proudu a napětí / The Protection System Working on Output of Electronic Sensor System Measuring Current and Voltage

Bajánek, Tomáš January 2017 (has links)
At present, there is a widespread use of alternative measurement technologies in electrical networks that include current and voltage sensors. Their use is closely related to the use of IEC 61850-9-2 for data transfer of measured values within the substation for the purpose of protection and measurement. The use of sensors and communication standard IEC 61850 together with high-speed Ethernet will simplify the concept of the arrangement of protection terminals in substations and enable the development of a new protection system based on central protection. The dissertation is focused on protection algorithms, which use the SV according to IEC 61850-9-2, and their implementation into the central protection model. Thesis describes development in the field of protection of substations and the currently available solutions using IEC 61850-9-2 and the principle of central protection. Thesis explains algorithms for selected protection functions - overcurrent protection, negative sequence overcurrent protection, logic busbar protection and differential protection. Further, thesis deals with the programming of protection function algorithms in LabView development environment in the form of a central protection model. The model processes data from a process bus according to IEC 61850-9-2 and sends a GOOSE message over Ethernet in the event of a failure. To verify the correct function of the programmed protection algorithms, a testing procedure was developed using OMICRON 256plus, the current sensor and the merging unit. The results of the testing of the central protection model and the proposed algorithms were compared with the results of testing the currently used protections. At the end, the thesis deals with the assessment of the benefits of central protection for protecting substations and the possibility of further utilization of the central protection model. The thesis highlights a new way of protecting the electrification system using digital data from MU transferred via the process bus described in IEC 61850-9-2.
3

Monitoring, protection, and voltage control of parallel power transformers based on IEC 61850-9-2 process bus

Pieters, Willem Diederick January 2019 (has links)
Thesis (MEng (Electrical Engineering)--Cape Peninsula University of Technology, 2019 / The purpose of an electrical power system is to supply electrical energy to the customers. Power transformers are required to transform the system voltage from generation to transmission and distribution levels. Protection and control systems must ensure that power system high voltage equipment such as transformers operate and deliver save, reliable and secure electricity supply. The aim of the project research work is to develop and implement a strategy, methods and algorithms for monitoring, protection and voltage control of parallel power transformers based on IEC 61850-9-2 process bus standard. NamPower is a power utility in Namibia. The IEC 61850 protocol for electrical substation automation system is used for the protection and control of 5 power transformers operated in parallel in an existing substation system. The IEC 61850-9-2 process bus standard is however not used in regards of Sampled Values (SV). Protection and control devices are connected to a substation communication network, routers and switches using fibre optic linked Ethernet. Inductive Current Transformers (CTs) and Voltage Transformers (VTs) secondary circuits are hardwired to Intelligent Electronic Devices (IEDs) and fibre optic links are not used for this purpose at process level communication. The research focuses on the implementation of the IEC 61850 standard with Merging Units (MUs) and sampled values to improve the existing implemented protection and control system at NamPower. This includes substation communication networks and MUs used for transformer protection, voltage regulator control and cooling fan control. At the present the CTs located at the transformer bushings and switchgear and the VTs located at the switchgear are hardwired to the inputs on protection and control IEDs. The research focuses on issues with the copper wires for voltage and currents signals and how these issues can be eliminated by using the MUs and the SV protocol. The MUs which are considered in this Thesis is to improve the voltage regulator control and the control of the cooling fan motors. The voltage regulator control IED is situated at the tap change motor drive of the On-Load Tap Changer (OLTC). The IED of each transformer is required to regulate the voltage level of the secondary side bus bar it is connected to. All the regulating IEDs are required to communicate with each other and collectively to control the bus bar voltage depending on the switching configuration of the parallel transformers. The control circuit for controlling the cooling fan motors is hardwired. Temperature analogue signal input into a programmable automation controller IED can be used for controlling the transformer cooling fans. A strategy, methods and algorithms for transformer protection, voltage regulator control and cooling fan motor control of parallel power transformers need to be developed and implemented based on IEC 61850-9-2 process bus. Power utilities and distributors can benefit from interpretation of the IEC 61850-9-2 standard and implementing MUs and SV in substations. MUs can be included in the power transformer protection, automation and control systems. A cost reduction in high voltage equipment, substation installation and commissioning costs and better performance of protection and control system are anticipated.
4

Contribuições para a implementação de um barramento de processo segundo a norma IEC 61850-9. / Contributions for implementation of a process bus according to IEC 61850-9-2 standard.

Igarashi, Gilberto 27 November 2015 (has links)
Desde seu lançamento, em 2002, a Norma IEC 61850 vem evoluindo para se tornar o padrão adotado nos Sistemas de Automação de Subestações. Dentre seus vários aspectos, destacam- se os serviços de tempo real, que permitem a implementação de funções de automação e de proteção dentro da subestação através da troca de mensagens específicas entre Dispositivos Eletrônicos Inteligentes através de um barramento digital de rede de dados. O objetivo central deste trabalho é explorar algumas das questões que envolvem a implementação de uma classe de serviços de tempo real: a transmissão de valores amostrados através de Serviços SMV, definidos pela Norma IEC 61850-9. Primeiramente, apresenta-se um breve resumo das principais características da Norma IEC 61850 que possibilitam o atendimento dos três requisitos por ela estabelecidos como base: a interoperabilidade entre dispositivos de diferentes fabricantes, a versatilidade na configuração e reconfiguração do Sistema de Automação da Subestação, e a possibilidade de implementação de novas tecnologias. Em seguida, explora-se com maior profundidade todos os aspectos relevantes à implementação dos Serviços SMV. Devido à complexidade deste assunto, o autor propõe abordá-lo sob a ótica de cinco tópicos interdependentes: variações da Norma IEC 61850-9, confiabilidade do barramento de processo, sincronismo de tempo, análise da qualidade da medição e segurança cibernética. Com base nos resultados apresentados neste estudo, propõem-se duas plataformas, um protótipo de Transformador de Potencial Óptico e um protótipo de Relé de Proteção Diferencial para transformadores de potência, com o objetivo de explorar alguns dos aspectos pertinentes à implementação de um barramento de processo de acordo com a Norma IEC 61850-9. Também foram realizados testes de geração e transmissão de mensagens contendo valores de amostras de tensão/corrente do sistema elétrico (denominadas de SV Messages) com a finalidade de implementá-las de fato e avaliar as ferramentas de mercado disponíveis. Por fim foi proposto um modelo para a simulação do sistema de potência em conjunto com a rede de comunicação utilizando o programa Matlab/Simulink. O autor espera que este trabalho contribua para esclarecer os vários conceitos envolvidos na implementação do barramento de processo definido pela Norma IEC 61850-9, auxiliando na pesquisa e no desenvolvimento de novas ferramentas e dispositivos, e no aprimoramento da Norma IEC 61850. / Since its introduction, in 2002, the IEC 61850 Standard has been evolved to become the standard adopted in Substation Automation Systems. Among its various aspects it can be highlighted the real-time services, which allows the implementation of automation and protection functions within the substation by exchanging specific messages between Intelligent Electronic Devices via a digital data bus network. The main objective of this text is to explore some issues about the implementation of one class of real-time services: the transmission of sampled values through SMV Services, defined by IEC 61850-9 Standard. First, it is presented a brief summary of the main features of IEC 61850 Standard which allows it to meet the three main requirements on this standard: interoperability between devices from different manufacturers, versatility in configuration and reconfiguration of Substation Automation System, and possibility of implementation of new technologies. Next, it is explored, with more details, all aspects involved in the implementation of SMV Services. Due to the complexity of this subject, the author proposes approaches it from the perspective of five interdependent topics: variations of IEC 61850-9 Standard, process bus reliability, time synchronism, analysis of measurement quality, and cyber security. Based on results presented two platforms are proposed, an Optical Voltage Transformer prototype and a Differential Protection Relay prototype for power transformers, in order to explore some of aspects related to the implementation of a process bus according to IEC 61850-9 Standard. It was executed also some tests of generation and transmission of messages containing samples values of voltage/current from power system (referred as SV Messages) in order to implement them in fact, and to evaluate available market tools. At the end it is propoused a model for simulation of power system and network communication using Matlab/Simulink software. The author hopes this work may contribute to clarify the various concepts involved in the implementation of a process bus according to IEC 61850-9 Standard, aiding in research and development of new tools and devices, and improvement of IEC 61850 Standard.
5

Contribuições para a implementação de um barramento de processo segundo a norma IEC 61850-9. / Contributions for implementation of a process bus according to IEC 61850-9-2 standard.

Gilberto Igarashi 27 November 2015 (has links)
Desde seu lançamento, em 2002, a Norma IEC 61850 vem evoluindo para se tornar o padrão adotado nos Sistemas de Automação de Subestações. Dentre seus vários aspectos, destacam- se os serviços de tempo real, que permitem a implementação de funções de automação e de proteção dentro da subestação através da troca de mensagens específicas entre Dispositivos Eletrônicos Inteligentes através de um barramento digital de rede de dados. O objetivo central deste trabalho é explorar algumas das questões que envolvem a implementação de uma classe de serviços de tempo real: a transmissão de valores amostrados através de Serviços SMV, definidos pela Norma IEC 61850-9. Primeiramente, apresenta-se um breve resumo das principais características da Norma IEC 61850 que possibilitam o atendimento dos três requisitos por ela estabelecidos como base: a interoperabilidade entre dispositivos de diferentes fabricantes, a versatilidade na configuração e reconfiguração do Sistema de Automação da Subestação, e a possibilidade de implementação de novas tecnologias. Em seguida, explora-se com maior profundidade todos os aspectos relevantes à implementação dos Serviços SMV. Devido à complexidade deste assunto, o autor propõe abordá-lo sob a ótica de cinco tópicos interdependentes: variações da Norma IEC 61850-9, confiabilidade do barramento de processo, sincronismo de tempo, análise da qualidade da medição e segurança cibernética. Com base nos resultados apresentados neste estudo, propõem-se duas plataformas, um protótipo de Transformador de Potencial Óptico e um protótipo de Relé de Proteção Diferencial para transformadores de potência, com o objetivo de explorar alguns dos aspectos pertinentes à implementação de um barramento de processo de acordo com a Norma IEC 61850-9. Também foram realizados testes de geração e transmissão de mensagens contendo valores de amostras de tensão/corrente do sistema elétrico (denominadas de SV Messages) com a finalidade de implementá-las de fato e avaliar as ferramentas de mercado disponíveis. Por fim foi proposto um modelo para a simulação do sistema de potência em conjunto com a rede de comunicação utilizando o programa Matlab/Simulink. O autor espera que este trabalho contribua para esclarecer os vários conceitos envolvidos na implementação do barramento de processo definido pela Norma IEC 61850-9, auxiliando na pesquisa e no desenvolvimento de novas ferramentas e dispositivos, e no aprimoramento da Norma IEC 61850. / Since its introduction, in 2002, the IEC 61850 Standard has been evolved to become the standard adopted in Substation Automation Systems. Among its various aspects it can be highlighted the real-time services, which allows the implementation of automation and protection functions within the substation by exchanging specific messages between Intelligent Electronic Devices via a digital data bus network. The main objective of this text is to explore some issues about the implementation of one class of real-time services: the transmission of sampled values through SMV Services, defined by IEC 61850-9 Standard. First, it is presented a brief summary of the main features of IEC 61850 Standard which allows it to meet the three main requirements on this standard: interoperability between devices from different manufacturers, versatility in configuration and reconfiguration of Substation Automation System, and possibility of implementation of new technologies. Next, it is explored, with more details, all aspects involved in the implementation of SMV Services. Due to the complexity of this subject, the author proposes approaches it from the perspective of five interdependent topics: variations of IEC 61850-9 Standard, process bus reliability, time synchronism, analysis of measurement quality, and cyber security. Based on results presented two platforms are proposed, an Optical Voltage Transformer prototype and a Differential Protection Relay prototype for power transformers, in order to explore some of aspects related to the implementation of a process bus according to IEC 61850-9 Standard. It was executed also some tests of generation and transmission of messages containing samples values of voltage/current from power system (referred as SV Messages) in order to implement them in fact, and to evaluate available market tools. At the end it is propoused a model for simulation of power system and network communication using Matlab/Simulink software. The author hopes this work may contribute to clarify the various concepts involved in the implementation of a process bus according to IEC 61850-9 Standard, aiding in research and development of new tools and devices, and improvement of IEC 61850 Standard.
6

Distanční ochrana využívající digitální vstupní data / Distance Protection Design Using Digital Input Data

Wannous, Kinan Hasan Wafaa January 2020 (has links)
Standard IEC 61850-9-2 definuje přenos vzorkovaných měřených hodnot (sampled measured values, SMV) prostřednictvím sítě Ethernet a využití SMV získaných ze slučovacích jednotek nebo přístrojových transformátorů. Implementace IEC 61850-9-2 závisí na vlastnostech datového souboru, jakými jsou časová synchronizace, počet vzorků a časový interval. Dizertační práce je zaměřena na algoritmy chránění a analýzu vlivu standardu IEC61850-9-2LE na fyzická zařízení ochran s analogově/digitálními vstupními daty o proudu a napětí. S ohledem na narůstající míru interakce mezi fyzickými zařízeními a komunikačními prvky byl navržen test pro analýzu komunikace pro rozvodnu využívající konvenční metody (analogové vstupy) a metody digitální založené na standardu IEC 61850-9-2. Práce dále popisuje funkci slučovací jednotky využívající standard IEC61850-9-2LE. Navržená metoda definuje zdroj SMV a analyzuje přenos dat. V rámci práce byl za využití softwaru Matlab naprogramován algoritmus ochrany. Vytvořený model je schopen vyhodnotit vliv harmonického zkreslení na funkci digitálních ochran a vliv přesycení proudového transformátoru na distanční ochranu. V práci jsou zhodnoceny i možnosti zrychlení testování systémů chránění s využitím neuronové sítě. Závěrečná kapitola se zabývá aplikacemi v reálném čase, využívajícími data z rozvodny v blízkosti Vysokého učení technického v Brně. K přenosu dat z rozvodny do univerzitní laboratoře je zde využíváno SMV přenášených optickým kabelem o délce 16 km. Aplikace je vytvořena v programu Matlab a je schopna číst data z ethernetového portu, dekódovat je, převést z formátu ASCII do desítkové soustavy a poté vykreslit průběhy proudu a napětí. Mezi vlastnosti aplikace se řadí jednoduchost použití, schopnost implementace funkcí distanční ochrany, výpočet RMS hodnot proudu a napětí a harmonického zkreslení, harmonická analýza prostřednictvím rychlé Fourierovy transformace a výpočet impedance poruchové smyčky. Všechny výpočty běží v reálném čase a provedena je i citlivostní analýza modelu.