• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 13
  • 13
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generation

CARVALHO, DIEGO V. de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:06:37Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:06:37Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
2

Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generation

CARVALHO, DIEGO V. de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:06:37Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:06:37Z (GMT). No. of bitstreams: 0 / O estudo do efeito da colimação nos detectores de radiação sobre a qualidade de imagem do tomógrafo industrial de terceira geração desenvolvido no IPEN/CNEN-SP é descrito neste trabalho. Três conjuntos de colimadores de chumbo foram projetados e confeccionados, sendo um com janelas retangulares de 2 x 5 x 50 mm e outro com 4 x 10 x 50 mm (largura x comprimento x profundidade) e um terceiro com orifício circular de 5 mm de diâmetro x 40 mm de profundidade. Os colimadores foram projetados para poderem ser facilmente substituídos entre si nos detectores de radiação. Paralelamente, foram confeccionados e utilizadas a eletrônica associada, constituída de analisadores de sinais tipo multicanal de 8 bits contendo a unidade de alta tensão e o amplificador. Dentre as vantagens deste sistema destaca-se a sua capacidade de análise multicanal rápida e possuir uma eletrônica mais simples. Valores de resolução energética comparável com a da literatura foram encontrados utilizando a eletrônica desenvolvida acoplada ao detector de radiação de NaI(Tl). Os efeitos dos colimadores foram avaliados pelas medidas tomográficas em um fantom de polimetilmetacrilato contendo componentes multifásicos estáticos (ferro, alumínio e ar). Fontes de radiação com energias de das fontes de 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV e 400 keV), de 137Cs (662 keV) e de 192Ir (317 keV, 468 keV e 602 keV) observou-se que a melhor imagem do fantom foi obtida com os colimadores de janelas retangulares (fendas) de 2 x 5 x 50 mm. Na avaliação dinâmica da formação de bolhas em coluna simuladora de processos industriais, a melhor imagem foi obtida com a fonte de 192Ir. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
3

Radiografia com neutrons em tempo - real

MENEZES, MARIO O. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:25:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:40Z (GMT). No. of bitstreams: 1 06914.pdf: 2955248 bytes, checksum: 106449a86e70d89b0638f2132a9326c4 (MD5) / Tese [Doutoramento] / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
4

Emprego dos policarbonatos makrofol-de e CR-30 em radiografia com neutrons

PEREIRA, MARCO A.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:25:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:33Z (GMT). No. of bitstreams: 1 11313.pdf: 4364467 bytes, checksum: 80dca67e716c2de36cf87cbbab397c48 (MD5) / Dissertacao (Mestrado) / IPEN/D / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP
5

Determinacao de defeitos em profundidade (estereoradiografia)

CARVALHO, GILBERTO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:50Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:49Z (GMT). No. of bitstreams: 1 07313.pdf: 4614224 bytes, checksum: b35f3b3a0d88e2ee74e856c2c7883aaf (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
6

Otimizacao do sistema de radioprotecao nas instalacoes radiograficas de gamagrafia

ANTONIO FILHO, JOAO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:44Z (GMT). No. of bitstreams: 1 06775.pdf: 15025996 bytes, checksum: fbd53da186ea56301e555ed353c39360 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
7

Radiografia com neutrons em tempo - real

MENEZES, MARIO O. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:25:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:40Z (GMT). No. of bitstreams: 1 06914.pdf: 2955248 bytes, checksum: 106449a86e70d89b0638f2132a9326c4 (MD5) / Tese [Doutoramento] / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
8

Emprego dos policarbonatos makrofol-de e CR-30 em radiografia com neutrons

PEREIRA, MARCO A.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:25:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:33Z (GMT). No. of bitstreams: 1 11313.pdf: 4364467 bytes, checksum: 80dca67e716c2de36cf87cbbab397c48 (MD5) / Dissertacao (Mestrado) / IPEN/D / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP
9

Determinacao de defeitos em profundidade (estereoradiografia)

CARVALHO, GILBERTO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:50Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:49Z (GMT). No. of bitstreams: 1 07313.pdf: 4614224 bytes, checksum: b35f3b3a0d88e2ee74e856c2c7883aaf (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
10

Otimizacao do sistema de radioprotecao nas instalacoes radiograficas de gamagrafia

ANTONIO FILHO, JOAO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:44Z (GMT). No. of bitstreams: 1 06775.pdf: 15025996 bytes, checksum: fbd53da186ea56301e555ed353c39360 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0294 seconds