• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do conforto termico em industrias de calçados

Voltani, Eder Ricardo 13 August 2018 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-13T19:58:30Z (GMT). No. of bitstreams: 1 Voltani_EderRicardo_M.pdf: 1781580 bytes, checksum: 4e5a97494a32fe55f6e8a82e215edab3 (MD5) Previous issue date: 2009 / Resumo: Os métodos Predicted Mean Vote ¿ PMV e Predicted Percentage Dissatisfied ¿ PPD foram desenvolvidos por Ole Fanger e significaram um expressivo avanço nos estudos sobre avaliação de conforto térmico. No ano de 1984 estes métodos foram adotados pela International Organization for Standardization ¿ ISO como base da norma 7730. No entanto, diversas pesquisas foram realizadas com o objetivo de encontrar a sensação térmica para pessoas expostas a diferentes combinações das variáveis ambientais e pessoais, pois existiam alguns questionamentos a respeito da aplicabilidade desta norma em campo e para diferentes regiões climáticas. Dessa forma, esta pesquisa tem por objetivo obter informações para a análise da aplicabilidade do modelo PMV/PPD da norma ISO 7730 (2005) como meio de avaliação do conforto térmico em ambientes de trabalhos industriais, onde a atividade seja leve ou moderada. Esta pesquisa foi desenvolvida nas indústrias de calçado feminino da região de Jaú, SP. Quanto à metodologia, foram obtidos os dados da temperatura do ar, umidade relativa, velocidade relativa do ar e temperatura radiante média, conforme recomendações da norma ISO 7726 (1998). O isolamento térmico das vestimentas e as taxas de metabolismo foram estimados por meio de valores referenciais de tabelas das normas ISO 9920 (1995) e ISO 8996 (1990), respectivamente. Para calcular os valores de PMV e PPD foi utilizado o Software Conforto 2.03. Os votos de Sensação e Preferência Térmica foram obtidos através de um questionário aplicado junto à população pesquisada. Com o desenvolvimento de análises de Regressão Simples e Probit, foi possível encontrar a zona de conforto térmico da população pesquisada, comparar a correlação, temperatura de neutralidade e a porcentagem de pessoas insatisfeitas entre os votos obtidos dos trabalhadores com os resultados dos cálculos do PMV/ PPD. Através de simulações foi possível identificar que a interpretação das atividades desenvolvidas, o tipo de questionário aplicado e o controle das respostas da população provocam desvios de 8%, 12% e 7,6%, respectivamente, nos resultados da correlação entre os votos das sensações térmicas e os resultados do calculo de PMV. Por meio da análise Probit dos votos de sensação e preferência térmica da população com 1,4 met foi possível obter a temperatura de neutralidade de 23,35 °C, com 84,5% da população em conforto térmico e 15,5% em desconforto térmico. Conforme cálculo de PMV, para as mesmas condições, a temperatura de neutralidade é 22,4 °C / Abstract: The methods Predicted Mean Vote ¿ PMV and Predicted Percentage Dissatisfied ¿ PPD were developed by Ole Fanger and represent a meaningful advance in studies about assessment of thermal comfort. In 1984 these methods were adopted by the International Organization for Standardization -ISO as the basis for standard 7730. However, several researches were made with the purpose of finding the thermal sensation of people exposed to different combinations of environmental and personal variables because of some questionings regarding its applicability in field and in different climatic regions. Therefore, the aim of this work has been to collect information for the analysis of the applicability of the PMV/PPD methods in the standard ISO 7730 (2005), as a means to evaluate thermal comfort in industrial work environment with light sedentary or moderate activity. The research was carried out in female shoe-making industries in the region of Jaú, State of São Paulo. The adopted methodology was defined as follows: data collecting of air temperature, relative humidity, the relative air velocity, and mean radiant temperature, according to the recommendations of ISO 7726 (1998). The clothing insulation and the metabolic rates were estimated by means of the referential value tables in ISO 9920 (1995) and ISO 8996 (1990), respectively. The Comfort Software 2.03 was used to calculate the PMV and the PPD values. Questionnaires were applied among the workers with questions involving the personnel vote for the Thermal Sensation and Preferences. By running the analyses of Simple Regression and Probit, is was possible to compare the correlation between the temperature of neutrality and the percentage of dissatisfied people amongst the personnel votes to the outcomes of the PMV/PPD figures. Through simulations it was possible to identify that the interpretation of activities, the type of questionnaire applied and the control of the responses of the population caused deviations of 8%, 12% and 7.6%, respectively, in the results of the correlation between the votes for thermal sensations and the results of the calculation of PMV. The analyses Probit with the votes of sensation and thermal preference of people with activity 1.4 met the temperature of neutrality was 23.35 °C, with 84.5% of population in comfort and 15.5% in thermal discomfort. As for the calculation of PMV, in the same conditions, the temperature of neutrality is 22.4 °C / Mestrado / Arquitetura e Construção / Mestre em Engenharia Civil
2

Desarrollo de modelos matemáticos y análisis de sensibilidad para el estudio energético de edificaciones

Robledo Fava, Roberto 07 January 2019 (has links)
Presentamos un análisis de la sensibilidad de los resultados de simulaciones numéricas basadas en Building Information Modeling (BIM), a las variaciones en los valores de los parámetros humanos subjetivos (SHP) definidos en la norma ISO 7730, como vestimenta o actividad. Nuestro análisis muestra que los pequeños cambios en los SHP pueden producir oscilaciones significativas en los resultados de los cálculos numéricos, que, en nuestro caso, se realizaron con el software TRNSYS. Para verificar la validez de nuestro enfoque, hemos implementado un código Monte Carlo, para analizar los efectos principales de las diferentes variables de forma sistemática. / Presentem una anàlisi de la sensibilitat dels resultats de simulacions numèriques basades en Building Information Modeling (BIM) , a les variacions en els valors dels paràmetres humans subjectius (SHP) definits en la norma ISO 7730, com a vestimenta o activitat. La nostra anàlisi mostra que els xicotets canvis en els SHP poden produir oscil·lacions significatives en els resultats dels càlculs numèrics, que, en el nostre cas, es van realitzar amb el programari TRNSYS. Per a verificar la validesa del nostre enfocament, hem implementat un codi Monte Carlo, per a analitzar els efectes principals de les diferents variables de forma sistemàtica. / We present an analysis of the sensitivity of the results of Building Information Modeling (BIM)-based numerical simulations, to variations in the values of subjective human parameters (SHPs) defined in the ISO standard 7730, like clothing or activity. Our analysis shows that slight changes on SHPs may yield significant oscillations on the results of the numerical calculations, which in our case were made with TRSYS software. To check the validity of our approach, we have implemented a Monte Carlo code, to analyze the main effects of the different variables in a systematic way. / Robledo Fava, R. (2018). Desarrollo de modelos matemáticos y análisis de sensibilidad para el estudio energético de edificaciones [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/114795 / TESIS
3

Avaliação de conforto térmico para consumidores de supermercado na cidade de Balneário Camboriú

Russo, Gustavo D`amaral Pereira Granja 31 July 2013 (has links)
Made available in DSpace on 2016-12-12T20:17:54Z (GMT). No. of bitstreams: 1 114385.pdf: 1033554 bytes, checksum: 0a2576777b25dd52f4ddfcf3ac5cf790 (MD5) Previous issue date: 2013-07-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A revisão da literatura acerca das questões relacionadas ao conforto térmico aponta que um desdobramento da ciência se dá no campo da adequação ou tentativa de proposição de um modelo de predição de conforto térmico para regiões de clima tropical. É neste sentido que o presente trabalho se desenvolve, tendo por objetivo encontrar a zona de conforto térmico para consumidores de supermercado da região de Balneário Camboriú, SC, Brasil. Especificamente a atividade de compras chamou a atenção pela escassez de material estudando a relação de conforto de pessoas neste tipo de atividade. A hipótese trabalhada busca corroborar as várias propostas já encontradas: a norma ISO 7730 - 1994 necessita de um fator de ajuste para se adequar às condições do público citado. O estudo apresentado traz resultados de medições ambientais, aplicação de questionário verificando a sensação e preferência térmica, e por fim a comparação dos resultados colhidos com a predição conforme ISO 7730/1994 - 1994. O resultado encontrado revela que a norma não está adequada ao caso pesquisado, e as pessoas pesquisadas têm preferência por um ambiente mais frio que o modelo predito.

Page generated in 0.0237 seconds