• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Predicting Task-­specific Performance for Iterative Reconstruction in Computed Tomography

Chen, Baiyu January 2014 (has links)
<p>The cross-sectional images of computed tomography (CT) are calculated from a series of projections using reconstruction methods. Recently introduced on clinical CT scanners, iterative reconstruction (IR) method enables potential patient dose reduction with significantly reduced image noise, but is limited by its "waxy" texture and nonlinear nature. To balance the advantages and disadvantages of IR, evaluations are needed with diagnostic accuracy as the endpoint. Moreover, evaluations need to take into consideration the type of the imaging task (detection and quantification), the properties of the task (lesion size, contrast, edge profile, etc.), and other acquisition and reconstruction parameters. </p><p>To evaluate detection tasks, the more acceptable method is observer studies, which involve image preparation, graphical user interface setup, manual detection and scoring, and statistical analyses. Because such evaluation can be time consuming, mathematical models have been proposed to efficiently predict observer performance in terms of a detectability index (d'). However, certain assumptions such as system linearity may need to be made, thus limiting the application of the models to potentially nonlinear IR. For evaluating quantification tasks, conventional method can also be time consuming as it usually involves experiments with anthropomorphic phantoms. A mathematical model similar to d' was therefore proposed for the prediction of volume quantification performance, named the estimability index (e'). However, this prior model was limited in its modeling of the task, modeling of the volume segmentation process, and assumption of system linearity.</p><p>To expand prior d' and e' models to the evaluations of IR performance, the first part of this dissertation developed an experimental methodology to characterize image noise and resolution in a manner that was relevant to nonlinear IR. Results showed that this method was efficient and meaningful in characterizing the system performance accounting for the non-linearity of IR at multiple contrast and noise levels. It was also shown that when certain criteria were met, the measurement error could be controlled to be less than 10% to allow challenging measuring conditions with low object contrast and high image noise.</p><p>The second part of this dissertation incorporated the noise and resolution characterizations developed in the first part into the d' calculations, and evaluated the performance of IR and conventional filtered backprojection (FBP) for detection tasks. Results showed that compared to FBP, IR required less dose to achieve a threshold performance accuracy level, therefore potentially reducing the required dose. The dose saving potential of IR was not constant, but dependent on the task properties, with subtle tasks (small size and low contrast) enabling more dose saving than conspicuous tasks. Results also showed that at a fixed dose level, IR allowed more subtle tasks to exceed a threshold performance level, demonstrating the overall superior performance of IR for detection tasks.</p><p>The third part of this dissertation evaluated IR performance in volume quantification tasks with conventional experimental method. The volume quantification performance of IR was measured using an anthropomorphic chest phantom and compared to FBP in terms of accuracy and precision. Results showed that across a wide range of dose and slice thickness, IR led to accuracy significantly different from that of FBP, highlighting the importance of calibrating or expanding current segmentation software to incorporate the image characteristics of IR. Results also showed that despite IR's great noise reduction in uniform regions, IR in general had quantification precision similar to that of FBP, possibly due to IR's diminished noise reduction at edges (such as nodule boundaries) and IR's loss of resolution at low dose levels. </p><p>The last part of this dissertation mathematically predicted IR performance in volume quantification tasks with an e' model that was extended in three respects, including the task modeling, the segmentation software modeling, and the characterizations of noise and resolution properties. Results showed that the extended e' model correlated with experimental precision across a range of image acquisition protocols, nodule sizes, and segmentation software. In addition, compared to experimental assessments of quantification performance, e' was significantly reduced in computational time, such that it can be easily employed in clinical studies to verify quantitative compliance and to optimize clinical protocols for CT volumetry.</p><p>The research in this dissertation has two important clinical implications. First, because d' values reflect the percent of detection accuracy and e' values reflect the quantification precision, this work provides a framework for evaluating IR with diagnostic accuracy as the endpoint. Second, because the calculations of d' and e' models are much more efficient compared to conventional observer studies, the clinical protocols with IR can be optimized in a timely fashion, and the compliance of clinical performance can be examined routinely.</p> / Dissertation
2

Secure digital documents using Steganography and QR Code

Hassanein, Mohamed Sameh January 2014 (has links)
With the increasing use of the Internet several problems have arisen regarding the processing of electronic documents. These include content filtering, content retrieval/search. Moreover, document security has taken a centre stage including copyright protection, broadcast monitoring etc. There is an acute need of an effective tool which can find the identity, location and the time when the document was created so that it can be determined whether or not the contents of the document were tampered with after creation. Owing the sensitivity of the large amounts of data which is processed on a daily basis, verifying the authenticity and integrity of a document is more important now than it ever was. Unsurprisingly document authenticity verification has become the centre of attention in the world of research. Consequently, this research is concerned with creating a tool which deals with the above problem. This research proposes the use of a Quick Response Code as a message carrier for Text Key-print. The Text Key-print is a novel method which employs the basic element of the language (i.e. Characters of the alphabet) in order to achieve authenticity of electronic documents through the transformation of its physical structure into a logical structured relationship. The resultant dimensional matrix is then converted into a binary stream and encapsulated with a serial number or URL inside a Quick response Code (QR code) to form a digital fingerprint mark. For hiding a QR code, two image steganography techniques were developed based upon the spatial and the transform domains. In the spatial domain, three methods were proposed and implemented based on the least significant bit insertion technique and the use of pseudorandom number generator to scatter the message into a set of arbitrary pixels. These methods utilise the three colour channels in the images based on the RGB model based in order to embed one, two or three bits per the eight bit channel which results in three different hiding capacities. The second technique is an adaptive approach in transforming domain where a threshold value is calculated under a predefined location for embedding in order to identify the embedding strength of the embedding technique. The quality of the generated stego images was evaluated using both objective (PSNR) and Subjective (DSCQS) methods to ensure the reliability of our proposed methods. The experimental results revealed that PSNR is not a strong indicator of the perceived stego image quality, but not a bad interpreter also of the actual quality of stego images. Since the visual difference between the cover and the stego image must be absolutely imperceptible to the human visual system, it was logically convenient to ask human observers with different qualifications and experience in the field of image processing to evaluate the perceived quality of the cover and the stego image. Thus, the subjective responses were analysed using statistical measurements to describe the distribution of the scores given by the assessors. Thus, the proposed scheme presents an alternative approach to protect digital documents rather than the traditional techniques of digital signature and watermarking.
3

Pokročilé metody snímání a hodnocení kvality 3D videa / Advanced Methods for 3D Video Capturing and Evaluation

Kaller, Ondřej January 2018 (has links)
Disertační práce se zabývá metodami snímání a hodnocení kvality 3D obrazů a videí. Po krátkém shrnutí fyziologie prostorového vnímání, obsahuje práce stav poznání v oblastech problému adaptivní paralaxy a konfigurace kamer pro snímání klasického stereopáru. Taktéž shrnuje dnešní možnosti odhadu hloubkové mapy. Zmíněny jsou aktivní i pasivní metody, detailněji je vysvětleno profilometrické skenování. Byly změřeny některé technické parametry dvou technologií současných 3D zobrazovačů, a to polarizačně-oddělujících a využívajících časový multiplex, například přeslechy mezi levým a pravým snímkem. Jádro práce tvoří nová metoda pro vytváření hloubkové mapy při snímání 3D scény, kterážto byla autorem navržena a testována. Inovativnost tohoto přístupu spočívá v chytré kombinaci současných aktivních a pasivních metod snímání hloubky scény, která vtipně využívá výhod obou metod. Nakonec jsou prezentovány výsledky subjektivních testů kvality 3D videa. Největší přínos zde má navržená metrika modelující výsledky subjektivních testů kvality 3D videa.

Page generated in 0.1212 seconds