• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Three-dimensional geometry characterization using structured light fields

Tavares, Paulo José da Silva January 2008 (has links)
Tese de doutoramento. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2008
2

Avaliação em 3D da cabeça da mandíbula em crianças portadoras de mordida cruzada posterior unilateral por meio de tomografia computadorizada de feixe cônico / 3D evaluation of the condyle in children with unilateral posterior cross bite using Cone Beam Computed Tomography

Illipronti Filho, Edson 20 January 2016 (has links)
Durante o desenvolvimento da oclusão, a instalação de maloclusões podem resultar em desarmonias dento faciais de natureza e severidade diversas, podendo provocar alterações no desenvolvimento crânio facial, dentre as estruturas envolvidas as Articulações Temporo Mandibulares (ATM), podem sofrer alguma influência, dessa forma a avaliação desta região, no aspecto morfológico e funcional, constituí tema de interesse, sempre que levados em conta os aspectos funcionais da oclusão. A relação entre a forma e a função, tanto das cabeças da mandíbula, bem como o contorno da fossa mandibular com as maloclusões ainda é controversa e não está compreendida por completo, porém a literatura sobre o assunto, demonstra correlação entre a instalação de maloclusões e modificações neste sistema, mesmo que algumas alterações não sejam de ordem estatística e em amostras de indivíduos em tenra idade, as mesmas podem comprometer o desenvolvimento adequado em indivíduos adultos ou mesmo adultos jovens. Tendo como propósito nesse estudo a avaliação das cabeças da mandíbula quanto ao volume e superficíe dos lados direito e esquerdo, cruzado e não cruzado, a amostra selecionada foi de 20 indivíduos com mordida cruzada posterior unilateral, com idades entre 06 e 09 anos de idade, utilizando imagens de tomografia computadorizada por feixe cônico, imagens obtidas por um equipamento modelo i- Cat, sendo utilizado na reformatação e manipulação das imagens o programa computacional - NemoCeph 3D® versão 11.5. Nas medições propostas para esse estudo, utilizou-se o teste t pareado de Student para amostras com distribuição normal. Na observação das tabelas e seus respectivos gráficos, podemos verificar que na comparação entre os lados direito e esquerdo, e cruzado e não cruzado das cabeças da mandíbula, com relação ao volume e superfície, existem diferenças numéricas entre elas, porém não pode ser observado diferenças estatísticas significantes, nessa amostra especifica com a metodologia empregada para esse estudo. Assim foi possível concluir que nas Mordidas Cruzadas Posteriores Unilaterais as cabeças da mandíbula tanto em seu volume como em sua superfície não apresentaram diferenças estatisticamente significantes na amostra estudada. / During the development of occlusion, malocclusions installation may result in disharmony dento facial nature and various severity, can cause changes in craniofacial development, among the structures involved in the temporomandibular joints mandibular (ATM), may suffer some influence, thus the evaluation of this region, the morphological and functional aspect, constitutes topic of interest, when taken into account the functional aspects of occlusion. The relationship between form and function, both the heads of the jaw, as well as the outline of the mandibular fossa with malocclusion remains controversial and is not fully understood, but the literature on the subject shows correlation between the installation of malocclusions and modifications to this system, even if some changes are not of statistical order and samples from individuals at an early age, they can compromise the proper development in adults and even young adults. With the intent of this study was to evaluate the heads of the jaw as the volume and surface of the right and left sides, crossed and uncrossed, the selected sample of 20 subjects with unilateral posterior cross bite, aged from 06 to 09 years old, using computed tomography cone beam, images obtained by a device model i-Cat, being used in reformatting and manipulation of images the computer program - NemoCeph 3D® version 11.5. The proposals measurements for this study, we used the paired t-test of Student for samples with normal distribution. The observation of the tables and their graphs, we can see that the comparison between the right and left sides, and crossed and uncrossed the heads of the mandible in relation to the volume and surface, there are numerical differences between them, but can not be observed differences statistically significant, this sample specifies the methodology used for this study. Thus it was concluded that the Unilateral Posterior Crossbites the heads of the jaw in both its volume and its surface showed no statistically significant differences
3

Avaliação em 3D da cabeça da mandíbula em crianças portadoras de mordida cruzada posterior unilateral por meio de tomografia computadorizada de feixe cônico / 3D evaluation of the condyle in children with unilateral posterior cross bite using Cone Beam Computed Tomography

Edson Illipronti Filho 20 January 2016 (has links)
Durante o desenvolvimento da oclusão, a instalação de maloclusões podem resultar em desarmonias dento faciais de natureza e severidade diversas, podendo provocar alterações no desenvolvimento crânio facial, dentre as estruturas envolvidas as Articulações Temporo Mandibulares (ATM), podem sofrer alguma influência, dessa forma a avaliação desta região, no aspecto morfológico e funcional, constituí tema de interesse, sempre que levados em conta os aspectos funcionais da oclusão. A relação entre a forma e a função, tanto das cabeças da mandíbula, bem como o contorno da fossa mandibular com as maloclusões ainda é controversa e não está compreendida por completo, porém a literatura sobre o assunto, demonstra correlação entre a instalação de maloclusões e modificações neste sistema, mesmo que algumas alterações não sejam de ordem estatística e em amostras de indivíduos em tenra idade, as mesmas podem comprometer o desenvolvimento adequado em indivíduos adultos ou mesmo adultos jovens. Tendo como propósito nesse estudo a avaliação das cabeças da mandíbula quanto ao volume e superficíe dos lados direito e esquerdo, cruzado e não cruzado, a amostra selecionada foi de 20 indivíduos com mordida cruzada posterior unilateral, com idades entre 06 e 09 anos de idade, utilizando imagens de tomografia computadorizada por feixe cônico, imagens obtidas por um equipamento modelo i- Cat, sendo utilizado na reformatação e manipulação das imagens o programa computacional - NemoCeph 3D® versão 11.5. Nas medições propostas para esse estudo, utilizou-se o teste t pareado de Student para amostras com distribuição normal. Na observação das tabelas e seus respectivos gráficos, podemos verificar que na comparação entre os lados direito e esquerdo, e cruzado e não cruzado das cabeças da mandíbula, com relação ao volume e superfície, existem diferenças numéricas entre elas, porém não pode ser observado diferenças estatísticas significantes, nessa amostra especifica com a metodologia empregada para esse estudo. Assim foi possível concluir que nas Mordidas Cruzadas Posteriores Unilaterais as cabeças da mandíbula tanto em seu volume como em sua superfície não apresentaram diferenças estatisticamente significantes na amostra estudada. / During the development of occlusion, malocclusions installation may result in disharmony dento facial nature and various severity, can cause changes in craniofacial development, among the structures involved in the temporomandibular joints mandibular (ATM), may suffer some influence, thus the evaluation of this region, the morphological and functional aspect, constitutes topic of interest, when taken into account the functional aspects of occlusion. The relationship between form and function, both the heads of the jaw, as well as the outline of the mandibular fossa with malocclusion remains controversial and is not fully understood, but the literature on the subject shows correlation between the installation of malocclusions and modifications to this system, even if some changes are not of statistical order and samples from individuals at an early age, they can compromise the proper development in adults and even young adults. With the intent of this study was to evaluate the heads of the jaw as the volume and surface of the right and left sides, crossed and uncrossed, the selected sample of 20 subjects with unilateral posterior cross bite, aged from 06 to 09 years old, using computed tomography cone beam, images obtained by a device model i-Cat, being used in reformatting and manipulation of images the computer program - NemoCeph 3D® version 11.5. The proposals measurements for this study, we used the paired t-test of Student for samples with normal distribution. The observation of the tables and their graphs, we can see that the comparison between the right and left sides, and crossed and uncrossed the heads of the mandible in relation to the volume and surface, there are numerical differences between them, but can not be observed differences statistically significant, this sample specifies the methodology used for this study. Thus it was concluded that the Unilateral Posterior Crossbites the heads of the jaw in both its volume and its surface showed no statistically significant differences
4

Análise da dinâmica e quantificação metabólica de imagens de medicina nuclear na modalidade PET/CT. / Analysis of the dynamic and metabolic quantification of nuclear medicine images in the PET/CT modality.

Florez Pacheco, Edward 28 March 2016 (has links)
A presença da Medicina Nuclear como modalidade de obtenção de imagens médicas é um dos principais procedimentos utilizados hoje nos centros de saúde, tendo como grande vantagem a capacidade de analisar o comportamento metabólico do paciente, traduzindo-se em diagnósticos precoces. Entretanto, sabe-se que a quantificação em Medicina Nuclear é dificultada por diversos fatores, entre os quais estão a correção de atenuação, espalhamento, algoritmos de reconstrução e modelos assumidos. Neste contexto, o principal objetivo deste projeto foi melhorar a acurácia e a precisão na análise de imagens de PET/CT via processos realísticos e bem controlados. Para esse fim, foi proposta a elaboração de uma estrutura modular, a qual está composta por um conjunto de passos consecutivamente interligados começando com a simulação de phantoms antropomórficos 3D para posteriormente gerar as projeções realísticas PET/CT usando a plataforma GATE (com simulação de Monte Carlo), em seguida é aplicada uma etapa de reconstrução de imagens 3D, na sequência as imagens são filtradas (por meio do filtro de Anscombe/Wiener para a redução de ruído Poisson caraterístico deste tipo de imagens) e, segmentadas (baseados na teoria Fuzzy Connectedness). Uma vez definida a região de interesse (ROI) foram produzidas as Curvas de Atividade de Entrada e Resultante requeridas no processo de análise da dinâmica de compartimentos com o qual foi obtida a quantificação do metabolismo do órgão ou estrutura de estudo. Finalmente, de uma maneira semelhante imagens PET/CT reais fornecidas pelo Instituto do Coração (InCor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP) foram analisadas. Portanto, concluiu-se que a etapa de filtragem tridimensional usando o filtro Anscombe/Wiener foi relevante e de alto impacto no processo de quantificação metabólica e em outras etapas importantes do projeto em geral. / The presence of Nuclear Medicine as a medical imaging modality is one of the main procedures utilized nowadays in medical centers, and the great advantage of that procedure is its capacity to analyze the metabolic behavior of the patient, resulting in early diagnoses. However, the quantification in Nuclear Medicine is known to be complicated by many factors, such as degradations due to attenuation, scattering, reconstruction algorithms and assumed models. In this context, the goal of this project is to improve the accuracy and the precision of quantification in PET/CT images by means of realistic and well-controlled processes. For this purpose, we proposed to develop a framework, which consists in a set of consecutively interlinked steps that is initiated with the simulation of 3D anthropomorphic phantoms. These phantoms were used to generate realistic PET/CT projections by applying the GATE platform (with Monte Carlo simulation). Then a 3D image reconstruction was executed, followed by a filtering process (using the Anscombe/Wiener filter to reduce Poisson noise characteristic of this type of images) and, a segmentation process (based on the Fuzzy Connectedness theory). After defining the region of interest (ROI), input activity and output response curves are required for the compartment analysis in order to obtain the Metabolic Quantification of the selected organ or structure. Finally, in the same manner real images provided from the Heart Institute (InCor) of Hospital das Clínicas, Faculty of Medicine, University of São Paulo (HC-FMUSP) were analysed. Therefore, it is concluded that the three-dimensional filtering step using the Ascombe/Wiener filter was preponderant and had a high impact on the metabolic quantification process and on other important stages of the whole project.
5

Análise da dinâmica e quantificação metabólica de imagens de medicina nuclear na modalidade PET/CT. / Analysis of the dynamic and metabolic quantification of nuclear medicine images in the PET/CT modality.

Edward Florez Pacheco 28 March 2016 (has links)
A presença da Medicina Nuclear como modalidade de obtenção de imagens médicas é um dos principais procedimentos utilizados hoje nos centros de saúde, tendo como grande vantagem a capacidade de analisar o comportamento metabólico do paciente, traduzindo-se em diagnósticos precoces. Entretanto, sabe-se que a quantificação em Medicina Nuclear é dificultada por diversos fatores, entre os quais estão a correção de atenuação, espalhamento, algoritmos de reconstrução e modelos assumidos. Neste contexto, o principal objetivo deste projeto foi melhorar a acurácia e a precisão na análise de imagens de PET/CT via processos realísticos e bem controlados. Para esse fim, foi proposta a elaboração de uma estrutura modular, a qual está composta por um conjunto de passos consecutivamente interligados começando com a simulação de phantoms antropomórficos 3D para posteriormente gerar as projeções realísticas PET/CT usando a plataforma GATE (com simulação de Monte Carlo), em seguida é aplicada uma etapa de reconstrução de imagens 3D, na sequência as imagens são filtradas (por meio do filtro de Anscombe/Wiener para a redução de ruído Poisson caraterístico deste tipo de imagens) e, segmentadas (baseados na teoria Fuzzy Connectedness). Uma vez definida a região de interesse (ROI) foram produzidas as Curvas de Atividade de Entrada e Resultante requeridas no processo de análise da dinâmica de compartimentos com o qual foi obtida a quantificação do metabolismo do órgão ou estrutura de estudo. Finalmente, de uma maneira semelhante imagens PET/CT reais fornecidas pelo Instituto do Coração (InCor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP) foram analisadas. Portanto, concluiu-se que a etapa de filtragem tridimensional usando o filtro Anscombe/Wiener foi relevante e de alto impacto no processo de quantificação metabólica e em outras etapas importantes do projeto em geral. / The presence of Nuclear Medicine as a medical imaging modality is one of the main procedures utilized nowadays in medical centers, and the great advantage of that procedure is its capacity to analyze the metabolic behavior of the patient, resulting in early diagnoses. However, the quantification in Nuclear Medicine is known to be complicated by many factors, such as degradations due to attenuation, scattering, reconstruction algorithms and assumed models. In this context, the goal of this project is to improve the accuracy and the precision of quantification in PET/CT images by means of realistic and well-controlled processes. For this purpose, we proposed to develop a framework, which consists in a set of consecutively interlinked steps that is initiated with the simulation of 3D anthropomorphic phantoms. These phantoms were used to generate realistic PET/CT projections by applying the GATE platform (with Monte Carlo simulation). Then a 3D image reconstruction was executed, followed by a filtering process (using the Anscombe/Wiener filter to reduce Poisson noise characteristic of this type of images) and, a segmentation process (based on the Fuzzy Connectedness theory). After defining the region of interest (ROI), input activity and output response curves are required for the compartment analysis in order to obtain the Metabolic Quantification of the selected organ or structure. Finally, in the same manner real images provided from the Heart Institute (InCor) of Hospital das Clínicas, Faculty of Medicine, University of São Paulo (HC-FMUSP) were analysed. Therefore, it is concluded that the three-dimensional filtering step using the Ascombe/Wiener filter was preponderant and had a high impact on the metabolic quantification process and on other important stages of the whole project.

Page generated in 0.1124 seconds