• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Nanoparticules multimodales à base de lanthanides pour l'imagerie biomédicale et le suivi de cellules mésenchymateuses / Lanthanide-based multimodal nanoparticles for biomedical imaging and mesenchymal cells tracking

Santelli, Julien 12 April 2018 (has links)
L'objectif de ces travaux a été de mettre en pratique l'utilisation de nanoparticules multimodales (NPs) à base de lanthanides pour l'imagerie biomédicale en général et le suivi de cellules mésenchymateuses (MSCs) en particulier. Dans cette optique, deux types de NPs ont été utilisées, présentant toutes deux une matrice d'oxysulfure de gadolinium (Gd2O2S) permettant l'imagerie par résonnance magnétique (IRM) et la tomodensitométrie. L'ajout d'éléments dopants apporte des propriétés de fluorescence : l'europium (Gd2O2S :Eu3+), plus adapté à un examen in vitro et le couple ytterbium/thulium (Gd2O2S :Yb3+/Tm3+) à un examen in vivo grâce au phénomène de conversion ascendante de photons (up-conversion). Nous avons, dans un premier temps, démontré la possibilité de visualiser ces NPs au cours du temps au sein d'un organisme vivant par des méthodes complémentaires (IRM et fluorescence). L'étude complète de leur distribution et des voies d'élimination nous a permis de mettre en évidence une métabolisation hépatobiliaire associée à une lente excrétion dans les fèces. Le marquage d'un grand nombre de types cellulaires (lignées et cellules primaires d'espèces différentes) a également mis en avant leur potentiel en tant que traceur cellulaire universel. Nous avons par la suite concentré nos travaux sur le suivi de cellules mésenchymateuses dans un contexte de thérapie cellulaire. La biocompatibilité cellulaire à court, moyen et long terme a été validée par une série d'analyses (MTT, rouge neutre, wound healing, différenciation) et la fiabilité du traceur a été confirmée par l'étude approfondie du marquage cellulaire. Enfin, après mise au point d'un système personnalisé dédié à l'imagerie par up-conversion chez le petit animal, nous avons pu réaliser le suivi de ces cellules marquées, au cours du temps après injection dans un organe solide. Nous avons alors été en mesure de visualiser les MSCs par imagerie multimodale : IRM ; tomodensitométrie et fluorescence par up-conversion. L'ensemble de ces résultats met en avant le potentiel de ces nanoparticules pour l'imagerie à long terme dans des études précliniques et/ou cliniques. / The objective of these works was to put into practice the use of lanthanide-based multimodal nanoparticles (NPs) for biomedical imaging in general and mesenchymal cells (MSCs) tracking in particular. To that purpose, two types of NPs have been used, both presenting a gadolinium oxysulfide (Gd2O2S) matrix allowing magnetic resonance imaging (MRI) and computed tomography. The addition of dopant elements brings fluorescence properties: europium (Gd2O2S :Eu3+) is more appropriate for an in vitro examination whereas the combination ytterbium/thulium (Gd2O2S :Yb3+/Tm3+) is more appropriate for an in vivo examination through the up-conversion process. First, we have demonstrated the possibility of visualizing those NPs over-time in a living organism with complementary methods (MRI and fluorescence). The complete study of their biodistribution and ways of elimination allowed us to highlight a hepatobiliary metabolization associated with a slow feces excretion. The labeling of a wide variety of cell types (lines and primary cells from different species) has also pointed out their potential as a universal cell tracer. Thereafter, we focused our research on mesenchymal cells tracking in a cell therapy context. Short, medium and long term biocompatibility was validated via a series of analyses (MTT, neutral red, wound healing and differentiation) and the reliability of the tracer was confirmed by detailed study of the cell labeling. Finally, after developing a custom-made system dedicated to up-conversion imaging in small animals, we were able to perform over-time tracking of those labeled cells after injection in a solid organ. We achieved multimodal imaging of the MSCs with MRI, computed tomography and up-conversion. Altogether, these results underline the potential of these nanoparticles for long term imaging in preclinical and/or clinical studies.
2

Limited angular range X-ray micro-computerized tomography : derivation of anatomical information as a prior for optical luminescence tomography / Micro-tomographie par rayons X à angle limité : dérivation d’une information anatomique a priori pour la tomographie optique par luminescence

Barquero, Harold 22 May 2015 (has links)
Cette thèse traite du couplage d'un tomographe optique par luminescence (LCT) et d'un tomographe par rayons X (XCT), en présence d'une contrainte sur la géométrie d'acquisition du XCT. La couverture angulaire du XCT est limitée à 90 degrés pour satisfaire des contraintes spatiales imposées par le LCT existant dans lequel le XCT doit être intégré. L'objectif est de dériver une information anatomique, à partir de l'image morphologique issue du XCT. Notre approche a consisté i) en l'implémentation d'un algorithme itératif régularisé pour la reconstruction tomographique à angle limité, ii) en la construction d'un atlas anatomique statistique de la souris et iii) en l'implémentation d'une chaîne automatique réalisant la segmentation des images XCT, l'attribution d'une signification anatomique aux éléments segmentés, le recalage de l'atlas statistique sur ces éléments et ainsi l'estimation des contours de certains tissus à faible contraste non identifiables en pratique dans une image XCT standard. / This thesis addresses the combination of an Optical Luminescence Tomograph (OLT) and X-ray Computerized Tomograph (XCT), dealing with geometrical constraints defined by the existing OLT system in which the XCT must be integrated. The result is an acquisition geometry of XCT with a 90 degrees angular range only. The aim is to derive an anatomical information from the morphological image obtained with the XCT. Our approach consisted i) in the implementation of a regularized iterative algorithm for the tomographic reconstruction with limited angle data, ii) in the construction of a statistical anatomical atlas of the mouse and iii) in the implementation of an automatic segmentation workflow performing the segmentation of XCT images, the labelling of the segmented elements, the registration of the statistical atlas on these elements and consequently the estimation of the outlines of low contrast tissues that can not be identified in practice in a standard XCT image.

Page generated in 0.3129 seconds