• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Planejamento de tarefas de manutenções centradas em confiabilidade para redes de distribuição de energia elétrica /

Rodríguez, Antonio Misari January 2017 (has links)
Orientador: José Roberto Sanches Mantovani / Resumo: Neste trabalho propõe-se o desenvolvimento de uma ferramenta computacional para a gestão eficiente de tarefas de manutenções de redes elétricas de distribuição; otimizando os recursos humanos e materiais, permitindo ações efetivas que preservem a qualidade da energia fornecida ao consumidor, procurando atender deste modo os critérios estabelecidos pelo PRODIST (Procedimento de Distribuição de Energia Elétrica no Sistema Elétrico Nacional). O problema é tratado como um modelo de otimização multi-objetivo não linear dinâmico misto. No modelo proposto, busca-se minimizar os custos com a realização de tarefas de manutenção em equipamentos e componentes dos sistemas de distribuição e maximizar a confiabilidade dos mesmos, sob as restrições dos índices individuais de continuidade e frequência do fornecimento de energia elétrica (o DIC e o FIC), da disponibilidade de recursos financeiros e de equipes de manutenção, entre outras. A modelagem é totalmente centrada sobre os índices de confiabilidade dos equipamentos e componentes, os quais são avaliados por uma abordagem envolvendo modelos probabilísticos de falhas e sistemas de inferência fuzzy. Para a solução do modelo utiliza-se um algoritmo evolutivo NSGA-II. / Mestre
2

Planejamento de tarefas de manutenções centradas em confiabilidade para redes de distribuição de energia elétrica / Planning of maintenance tasks centered in reliability for power distribution systems

Rodríguez, Antonio Misari [UNESP] 16 August 2017 (has links)
Submitted by ANTONIO MISARI RODRÍGUEZ null (antonio4330@gmail.com) on 2017-10-03T11:39:54Z No. of bitstreams: 1 Dissertação_Mestrado.pdf: 6919936 bytes, checksum: b093314169f27d80cbe2ab33097636a8 (MD5) / Approved for entry into archive by Monique Sasaki (sayumi_sasaki@hotmail.com) on 2017-10-03T16:33:47Z (GMT) No. of bitstreams: 1 rodriguez_am_me_ilha.pdf: 6919936 bytes, checksum: b093314169f27d80cbe2ab33097636a8 (MD5) / Made available in DSpace on 2017-10-03T16:33:47Z (GMT). No. of bitstreams: 1 rodriguez_am_me_ilha.pdf: 6919936 bytes, checksum: b093314169f27d80cbe2ab33097636a8 (MD5) Previous issue date: 2017-08-16 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Neste trabalho propõe-se o desenvolvimento de uma ferramenta computacional para a gestão eficiente de tarefas de manutenções de redes elétricas de distribuição; otimizando os recursos humanos e materiais, permitindo ações efetivas que preservem a qualidade da energia fornecida ao consumidor, procurando atender deste modo os critérios estabelecidos pelo PRODIST (Procedimento de Distribuição de Energia Elétrica no Sistema Elétrico Nacional). O problema é tratado como um modelo de otimização multi-objetivo não linear dinâmico misto. No modelo proposto, busca-se minimizar os custos com a realização de tarefas de manutenção em equipamentos e componentes dos sistemas de distribuição e maximizar a confiabilidade dos mesmos, sob as restrições dos índices individuais de continuidade e frequência do fornecimento de energia elétrica (o DIC e o FIC), da disponibilidade de recursos financeiros e de equipes de manutenção, entre outras. A modelagem é totalmente centrada sobre os índices de confiabilidade dos equipamentos e componentes, os quais são avaliados por uma abordagem envolvendo modelos probabilísticos de falhas e sistemas de inferência fuzzy. Para a solução do modelo utiliza-se um algoritmo evolutivo NSGA-II. / In this work, the development of a computational tool for the efficient management of maintenance tasks of electrical distribution networks is proposed; optimizing human and material resources, allowing effective actions that preserve the quality of energy supplied to the consumer, thus seeking to meet the criteria established by PRODIST (Procedure for Distribution of Electric Energy in the National Electric System). The problem is treated as a mixed dynamic nonlinear multi-objective optimization model. In the proposed model, it is sought to minimize the costs of performing maintenance tasks on equipment and components of the distribution systems and to maximize their reliability, under the constraints of individual indices of continuity and frequency of electric power supply (DIC and FIC), of the availability of financial resources and maintenance equipment, among others. The modeling is totally focused on the reliability indices of the equipment and components, which are evaluated by an approach involving probabilistic fault models and fuzzy inference systems. For the solution of the model, an evolutionary algorithm NSGA-II is used. / CNPq: 159614/2015-5
3

Metodologia experimental para testes padronizados de confiabilidade em dispositivos indicadores de faltas / Experimental methodology for standardized reliability tests in fault indicator devices

Bacalini, Marcelo 12 December 2011 (has links)
Os dispositivos indicadores de faltas são utilizados para sinalizar a passagem de uma corrente de curto-circuito nos alimentadores de distribuição de energia elétrica. Tais dispositivos permitem uma redução significativa no tempo de inspeção das equipes de manutenção durante a busca pela região faltosa. Entretanto, associada a estes dispositivos, encontra-se uma elevada taxa de falhas de suas operações, que comprometem a confiabilidade do equipamento e, conseqüentemente, o tempo de localização de faltas. Neste trabalho é apresentada uma metodologia de ensaios laboratoriais a fim de complementar os testes padrões dos fabricantes de indicadores de faltas, buscando-se então identificar os fatores que colaboram para as falhas de tais equipamentos. Os resultados obtidos mostraram a eficiência da metodologia desenvolvida em detectar falhas de operação dos indicadores de faltas, as quais também não puderam ser detectadas por testes fornecidos por fabricantes. / Fault Indicators are devices used to signal the passage of a short-circuit current in electricity distribution feeders. Such devices allow a significant reduction in patrol time by maintenance linemen during the search for the faulty region. However, associated with these devices, it is a high failure rate of operations that compromise the equipment reliability and, consequently, the time of fault location. This work presents a new methodology for single-phase laboratory tests in order to complement the standard tests accomplished by the manufacturers of fault indicators, aiming to then identify the factors that contribute to failures of such equipment. The results showed the efficiency of the methodology developed to detect operation failures of faults indicators that could not be detected by tests provided by manufacturers.
4

Metodologia experimental para testes padronizados de confiabilidade em dispositivos indicadores de faltas / Experimental methodology for standardized reliability tests in fault indicator devices

Marcelo Bacalini 12 December 2011 (has links)
Os dispositivos indicadores de faltas são utilizados para sinalizar a passagem de uma corrente de curto-circuito nos alimentadores de distribuição de energia elétrica. Tais dispositivos permitem uma redução significativa no tempo de inspeção das equipes de manutenção durante a busca pela região faltosa. Entretanto, associada a estes dispositivos, encontra-se uma elevada taxa de falhas de suas operações, que comprometem a confiabilidade do equipamento e, conseqüentemente, o tempo de localização de faltas. Neste trabalho é apresentada uma metodologia de ensaios laboratoriais a fim de complementar os testes padrões dos fabricantes de indicadores de faltas, buscando-se então identificar os fatores que colaboram para as falhas de tais equipamentos. Os resultados obtidos mostraram a eficiência da metodologia desenvolvida em detectar falhas de operação dos indicadores de faltas, as quais também não puderam ser detectadas por testes fornecidos por fabricantes. / Fault Indicators are devices used to signal the passage of a short-circuit current in electricity distribution feeders. Such devices allow a significant reduction in patrol time by maintenance linemen during the search for the faulty region. However, associated with these devices, it is a high failure rate of operations that compromise the equipment reliability and, consequently, the time of fault location. This work presents a new methodology for single-phase laboratory tests in order to complement the standard tests accomplished by the manufacturers of fault indicators, aiming to then identify the factors that contribute to failures of such equipment. The results showed the efficiency of the methodology developed to detect operation failures of faults indicators that could not be detected by tests provided by manufacturers.

Page generated in 0.0781 seconds