• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação in vitro da infiltração marginal em inlays de resinas compostas em função de tipos de fontes de luz e agentes de cimentação

Calabrez Filho, Saturnino [UNESP] 14 September 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-09-14Bitstream added on 2014-06-13T19:41:15Z : No. of bitstreams: 1 calabrezfilho_s_dr_arafo.pdf: 1543575 bytes, checksum: 53cda3ebc681f14a9c6a7769226d8a18 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a infiltração marginal da resina Flow Filtek e do cimento resinoso dual RelyX na fixação de inlays de cerômeros fotoativados com LEDs e Luz Halógena. Foram selecionados 32 dentes íntegros recém-extraídos armazenados em solução de soro fisiológico no freezer, divididos em quatro grupos: Grupo I - aparelho Elipar FreeLight e resina Flow Filtek ; Grupo II - aparelho Ultralux® e Resina Flow Filtek ; Grupo III - aparelho Elipar FreeLight e cimento resinoso RelyX e Grupo IV - aparelho Ultralux® e cimento resinoso RelyX . Foram feitos 64 preparos cavitários com término em esmalte e cemento a 1 mm acima e abaixo da junção amelo-cementária respectivamente. As inlays foram jateadas internamente com óxido de alumínio de 100 æm com 40 Bar de pressão e, posteriormente foi feito o condicionamento das superfícies das inlays com ácido fosfórico a 37% durante 60 segundos, as quais foram lavadas e silanizadas. Após o condicionamento das inlays, foi feito o preparo da superfície dental com ácido fosfórico a 37% durante 15 segundos, as quais foram lavadas, secas com papel absorvente, tendo sido aplicado o adesivo dentinário Single Bond (3m/Espe), e fixadas com seus respectivos cimentos. Posteriormente à fixação, foram fotoativadas pelos aparelhos em íntimo contato com sua superfície por 60 segundos, termociclados com 1.000 ciclos variando-se a temperatura de 5ºC a 55ºC, em seguida imersas em solução de fucsina básica a 5% durante 24 horas, lavadas e seccionadas no centro da restauração para que fosse feita a medida da infiltração em um Software Image Tool calibrado em milímetros, pelo qual foram selecionados os resultados que apresentavam maiores infiltrações em medidas lineares para aplicação dos testes estatísticos.... / The objective of this work was to evaluate the microleakage of the Flow Filtek resin and dual luting RelyX in the fixation of composite resin inlays cured with LEDs and Halogenic Light units. 32 recently extracted complete teeth were selected stored in solution of physiologic serum in freezer, divided in four groups: I Group I- Elipar FreeLight unit and Flow Filtek resin; Group II- Ultralux® unit Flow Filtek resin; Group III- Elipar FreeLight unit and RelyX luting and Group IV- Ultralux® unit RelyX luting. They were made 64 cavitary preparations with end in enamel and dentine with 1 mm above and below enamel-dentin junction respectively, the inlays were sandblasted internally with 100æm/40 pressure Bar and later made the conditioning of the surfaces of the inlays with phosphoric acid to 37% goes 60 seconds, washed and silanizadas. After the conditioning of the inlays they were made the preparation of the dental surface with phosphoric acid to 37% for 15 seconds, washed, dried with absorbent and applied paper the dentinal sticker Single Bond (3m/Espe) and fastened with their respective luting. Later the fixation, these were cured for the units in intimate contact with its surface for 60 seconds. The samples were then thermocycled with 1000 cycles varying the temperature of 5ºC and 55ºC, soon afterwards immersed in solution of basic fucsina to 5% for 24 hours, washed and split up in the center of the restoration so that it was made the measure of the microleakage in a Software Image Tool gaged in millimeters, where they were selected the results that presented larger leakage in lineal measures for application of the statistical tests... (Complete abstract, click electronic address below).
2

Avaliação in vitro da infiltração marginal em inlays de resinas compostas em função de tipos de fontes de luz e agentes de cimentação /

Calabrez Filho, Saturnino. January 2005 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: José Roberto Cury Saad / Banca: Osmir Batista de Oliveira Júnior / Banca: Luis Henrique Borges / Banca: Fernando Carlos Hueb de Menezes / Resumo: O objetivo deste trabalho foi avaliar a infiltração marginal da resina Flow Filtek™ e do cimento resinoso dual RelyX™ na fixação de inlays de cerômeros fotoativados com LEDs e Luz "Halógena". Foram selecionados 32 dentes íntegros recém-extraídos armazenados em solução de soro fisiológico no freezer, divididos em quatro grupos: Grupo I - aparelho Elipar™ FreeLight e resina Flow Filtek™; Grupo II - aparelho Ultralux® e Resina Flow Filtek™; Grupo III - aparelho Elipar™FreeLight e cimento resinoso RelyX™ e Grupo IV - aparelho Ultralux® e cimento resinoso RelyX™. Foram feitos 64 preparos cavitários com término em esmalte e cemento a 1 mm acima e abaixo da junção amelo-cementária respectivamente. As inlays foram jateadas internamente com óxido de alumínio de 100 æm com 40 Bar de pressão e, posteriormente foi feito o condicionamento das superfícies das inlays com ácido fosfórico a 37% durante 60 segundos, as quais foram lavadas e silanizadas. Após o condicionamento das inlays, foi feito o preparo da superfície dental com ácido fosfórico a 37% durante 15 segundos, as quais foram lavadas, secas com papel absorvente, tendo sido aplicado o adesivo dentinário Single Bond™ (3m/Espe), e fixadas com seus respectivos cimentos. Posteriormente à fixação, foram fotoativadas pelos aparelhos em íntimo contato com sua superfície por 60 segundos, termociclados com 1.000 ciclos variando-se a temperatura de 5ºC a 55ºC, em seguida imersas em solução de fucsina básica a 5% durante 24 horas, lavadas e seccionadas no centro da restauração para que fosse feita a medida da infiltração em um Software Image Tool calibrado em milímetros, pelo qual foram selecionados os resultados que apresentavam maiores infiltrações em medidas lineares para aplicação dos testes estatísticos...(Resumo completo, clicar no acesso eletrônico abaixo). / Abstract: The objective of this work was to evaluate the microleakage of the Flow Filtek™resin and dual luting RelyX™ in the fixation of composite resin inlays cured with LEDs and Halogenic Light units. 32 recently extracted complete teeth were selected stored in solution of physiologic serum in freezer, divided in four groups: I Group I- Elipar™ FreeLight unit and Flow Filtek™ resin; Group II- Ultralux® unit Flow Filtek™resin; Group III- Elipar™FreeLight unit and RelyX™ luting and Group IV- Ultralux® unit RelyX™luting. They were made 64 cavitary preparations with end in enamel and dentine with 1 mm above and below enamel-dentin junction respectively, the inlays were sandblasted internally with 100æm/40 pressure Bar and later made the conditioning of the surfaces of the inlays with phosphoric acid to 37% goes 60 seconds, washed and silanizadas. After the conditioning of the inlays they were made the preparation of the dental surface with phosphoric acid to 37% for 15 seconds, washed, dried with absorbent and applied paper the dentinal sticker Single Bond™ (3m/Espe) and fastened with their respective luting. Later the fixation, these were cured for the units in intimate contact with its surface for 60 seconds. The samples were then thermocycled with 1000 cycles varying the temperature of 5ºC and 55ºC, soon afterwards immersed in solution of basic fucsina to 5% for 24 hours, washed and split up in the center of the restoration so that it was made the measure of the microleakage in a Software Image Tool gaged in millimeters, where they were selected the results that presented larger leakage in lineal measures for application of the statistical tests... (Complete abstract, click electronic address below). / Doutor

Page generated in 0.1039 seconds