• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Versatile low-energy electron source at the PHIL accelerator to characterise Micromegas with integrated Timepix CMOS readout and study dE/dx for low energy electrons / Source polyvalente d'électrons de basse énergie sur l'accélérateur PHIL pour caractériser des détecteurs Micromegas avec une lecture CMOS intégrée et étudier dE/dx pour les électrons de basse énergie

Krylov, Vladyslav 12 June 2018 (has links)
Dans le cadre de cette thèse, la conception, la construction et la mise en service de la plateforme de test LEETECH ont été réalisées. La performance de LEETECH, y compris le mode de fonctionnement à faible multiplicité a été démontrée. En fournissant des paquets d’électrons avec une énergie ajustable jusqu’à 3.5 MeV, une multiplicité ajustable à partir d’électrons simples et une durée des paquets jusqu’à 20ps, LEETECH prend sa place entre les faisceaux tests de hautes énergies et de coûts élevés d’un part et l’utilisation de sources radioactifs d’autre part. Dans la région, qui correspond à la particule d’ionisation minimale, la plateforme offre aux détecteurs de traces les conditions similaires aux celles de faisceaux des hautes énergies. Le mode de fonctionnement à faible multiplicité a été étudié en utilisant un détecteur diamant de grande surface. En plus une capacité d’un capteur diamant de résoudre des paquets à faible nombre des particules a été démontrée. Dans le cadre du développement de la chambre à projection temporelle (TPC) pour le projet ILC, une session de test a été dédiée à un détecteur Micromegas/InGrid de large surface. Pour la première fois les pertes d’énergie par un électron dans un mélange de gaz basée sur Helium ont été mesurées pour une énergie de quelques MeV. La résolution en dE/dx et un algorithme pour la reconstruction de traces ont été développés. Une caractérisation préliminaire du quartz barre lu par MCPPMT – un candidat pour le détecteur temps-de- vol (TOF) avec la mission de l’identification des hadrons chargés dans le futur usine tau-charm HIEPA – a été accomplie. La résolution temporelle de 50 ps obtenue pour le détecteur étudié met cette technologie prometteuse pour les études plus approfondies. / Within the present thesis the design, construction and commissioning of a new test beam facility LEETECH have been performed. Performance of the new facility, including low-multiplicity operation mode has been demonstrated. A number of interesting detector tests, including large-area diamond, Micromegas/InGrid and quartz bar detectors have been performed. Development of new detector technologies for future high-energy physics collider experiments calls for selection of versatile test beam facilities, permitting to choose or adjust beam parameters such as particles type, energy and beam intensity, are irreplaceable in characterization and tests of developed instruments. Major applications comprise generic detector R&D, conceptual design and choice of detector technologies, technical design, prototypes and full-scale detector construction and tests, detector calibration and commissioning. A new test beam facility LEETECH (Low Energy Electron TECHnique) was designed, constructed and commissioned in LAL (Orsay) as an extension of existing PHIL accelerator. Providing electron bunches of adjustable energy (up to 3.5 MeV), intensity (starting from a few particles per bunch) and bunch time duration (down to 20 ps), LEETECH fills the gap between high-cost high-energy test beam facilities and use of radioactive sources. Covering a minimum-ionization particles region (electrons of energy above 1.6 MeV), LEETECH provides for tracking detectors similar conditions as high-energy facilities. Using LEETECH as an electron source, several types of detectors were investigated in order to study their performance or applications, also providing a characterization of the LEETECH performance. First studies of the LEETECH facility were performed with a plastic scintillator coupled to the Micro-channel plate photomultiplier. A low-multiplicity mode was investigated using the diamond sensor, at the same time demonstrating its ability to resolve bunches consisting of a few particles. In framework of Time Projection Chamber development for the ILC project, a session dedicated to a large-area Micromegas/InGrid module was performed. For the first time the electron energy losses in Helium-based gas mixtures were measured for the energies of few MeV. The dE/dx resolution was obtained and track reconstruction algorithm was developed. Being a candidate for the time-of- flight detector of the BESIII upgrade and future HIEPA tau-charm factories, a preliminary characterization of the quartz bar performed. The time resolution of the detector module of 50 ps was obtained, giving a promising results for the further detector studies.
2

Développement et optimisation des diagnostiques des faisceaux du LHC et du SPS basé sur le suivi de la lumière synchrotron / Development and Optimization of the LHC and the SPS Beam Diagnostics Based on Synchrotron Radiation Monitoring

Trad, Georges 22 January 2015 (has links)
La mesure de l’émittance transverse du faisceau est fondamentale pour tous les accélérateurs, et en particulier pour les collisionneurs, son évaluation precise étant essentielle pour maximiser la luminosité et ainsi la performance des faisceaux de collision.Le rayonnement synchrotron (SR) est un outil polyvalent pour le diagnostic non-destructif de faisceau, exploité au CERN pour mesurer la taille des faisceaux de protons des deux machines du complexe dont l’énergie est la plus élevée, le SPS et le LHC où l’intensité du faisceau ne permet plus les techniques invasives.Le travail de thèse documenté dans ce rapport s’est concentré sur la conception, le développement, la caractérisation et l’optimisation des moniteurs de taille de faisceau basés sur le SR. Cette étude est fondée sur un ensemble de calculs théoriques, de simulation numériques et d’expériences conduite au sein des laboratoires et accélérateurs du CERN. Un outil de simulation puissant a été développé, combinant des logiciels classiques de simulation de SR et de propagation optique, permettant ainsi la caractérisation complète d’un moniteur SR de la source jusqu’au détecteur.La source SR a pu être entièrement caractérisée par cette technique, puis les résultats validés par observation directe et par la calibration à basse énergie basée sur les mesures effectuées avec les wire-scanners (WS), qui sont la référence en terme de mesure de taille de faisceau, ou telles que la comparaison directe avec la taille des faisceaux obtenue par déconvolution de la luminosité instantanée du LHC.Avec l’augmentation de l’énergie dans le LHC (7TeV), le faisceau verra sa taille diminuer jusqu’à atteindre la limite de la technique d’imagerie du SR. Ainsi, plusieurs solutions ont été investiguées afin d’améliorer la performance du système: la sélection d’une des deux polarisations du SR, la réduction des effets liés à la profondeur de champ par l’utilisation de fentes optiques et l’utilisation d’une longueur d’onde réduite à 250 nm.En parallèle à l’effort de réduction de la diffraction optique, le miroir d’extraction du SR qui s’était avéré être la source principale des aberrations du système a été entièrement reconçu. En effet, la détérioration du miroir a été causée par son couplage EM avec les champs du faisceau, ce qui a conduit à une surchauffe du coating et à sa dégradation. Une nouvelle géométrie de miroir et de son support permettant une douce transition en termes de couplage d’impédance longitudinale dans le beam pipe a été définie et caractérisée par la technique dite du “streched wire”. Egalement, comme méthode alternative à l’imagerie directe, un nouveau moniteur basé sur la technique d’interférométrie à deux fentes du SR, non limité par la diffraction, a également été développé. Le principe de cette méthode est basé sur la relation directe entre la visibilité des franges d’interférence et la taille de faisceau.Comme l’emittance du faisceau est la donnée d’intérêt pour la performance du LHC, il est aussi important de caractériser avec précision l’optique du LHC à la source du SR. Dans ce but, la méthode “K-modulation” a été utilisée pour la première fois au LHC en IR4. Les β ont été mesurés à l’emplacement de tous les quadrupoles et ont été évalués via deux algorithmes de propagation différents au BSRT et au WS. / Measuring the beam transverse emittance is fundamental in every accelerator, in particular for colliders, where its precise determination is essential to maximize the luminosity and thus the performance of the colliding beams.
 Synchrotron Radiation (SR) is a versatile tool for non-destructive beam diagnostics, since its characteristics are closely related to those of the source beam. At CERN, being the only available diagnostics at high beam intensity and energy, SR monitors are exploited as the proton beam size monitor of the two higher energy machines, the Super Proton Synchrotron (SPS) and the Large Hadron Collider (LHC). The thesis work documented in this report focused on the design, development, characterization and optimization of these beam size monitors. Such studies were based on a comprehensive set of theoretical calculations, numerical simulations and experiments.A powerful simulation tool has been developed combining conventional softwares for SR simulation and optics design, thus allowing the description of an SR monitor from its source up to the detector. 
The simulations were confirmed by direct observations, and a detailed performance studies of the operational SR imaging monitor in the LHC, where different techniques for experimentally validating the system were applied, such as cross-calibrations with the wire scanners at low intensity (that are considered as a reference) and direct comparison with beam sizes de-convoluted from the LHC luminosity measurements.In 2015, the beam sizes to be measured with the further increase of the LHC beam energy to 7 TeV will decrease down to ∼190 μm. In these conditions, the SR imaging technique was found at its limits of applicability since the error on the beam size determination is proportional to the ratio of the system resolution and the measured beam size. Therefore, various solutions were probed to improve the system’s performance such as the choice of one light polarization, the reduction of depth of field effect and the reduction of the imaging wavelength down to 250 nm.In parallel to reducing the diffraction contribution to the resolution broadening, the extraction mirror, found as the main sources of aberrations in the system was redesigned. Its failure was caused by the EM coupling with the beam’s fields that led to overheating and deterioration of the coating. A new system’s geometry featuring a smoother transition in the beam pipe was qualified in terms of longitudinal coupling impedance via the stretched wire technique. A comparison with the older system was carried out and resulted in a reduction of the total power dissipated in the extraction system by at least a factor of four.A new, non-diffraction limited, SR-based monitor based on double slit interferometry was designed as well as an alternative method to the direct imaging. Its principle is based on the direct relation between the interferogram fringes visibility and the beam size.Since the beam emittance is the physical quantity of interest in the performance analysis of the LHC, determining the optical functions at the SR monitors is as relevant as measuring the beam size. The “K-modulation” method for the optical function determination was applied for the first time in the LHC IR4, where most of the profile monitors sit. The βs at the quadrupoles were measured and via two different propagation algorithms the βs at the BSRT and the WS were obtained reducing significantly the uncertainty at the monitors location.
3

Développement et optimisation des diagnostiques des faisceaux du LHC et du SPS basé sur le suivi de la lumière synchrotron / Development and Optimization of the LHC and the SPS Beam Diagnostics Based on Synchrotron Radiation Monitoring

Trad, Georges 22 January 2015 (has links)
La mesure de l’émittance transverse du faisceau est fondamentale pour tous les accélérateurs, et en particulier pour les collisionneurs, son évaluation precise étant essentielle pour maximiser la luminosité et ainsi la performance des faisceaux de collision.Le rayonnement synchrotron (SR) est un outil polyvalent pour le diagnostic non-destructif de faisceau, exploité au CERN pour mesurer la taille des faisceaux de protons des deux machines du complexe dont l’énergie est la plus élevée, le SPS et le LHC où l’intensité du faisceau ne permet plus les techniques invasives.Le travail de thèse documenté dans ce rapport s’est concentré sur la conception, le développement, la caractérisation et l’optimisation des moniteurs de taille de faisceau basés sur le SR. Cette étude est fondée sur un ensemble de calculs théoriques, de simulation numériques et d’expériences conduite au sein des laboratoires et accélérateurs du CERN. Un outil de simulation puissant a été développé, combinant des logiciels classiques de simulation de SR et de propagation optique, permettant ainsi la caractérisation complète d’un moniteur SR de la source jusqu’au détecteur.La source SR a pu être entièrement caractérisée par cette technique, puis les résultats validés par observation directe et par la calibration à basse énergie basée sur les mesures effectuées avec les wire-scanners (WS), qui sont la référence en terme de mesure de taille de faisceau, ou telles que la comparaison directe avec la taille des faisceaux obtenue par déconvolution de la luminosité instantanée du LHC.Avec l’augmentation de l’énergie dans le LHC (7TeV), le faisceau verra sa taille diminuer jusqu’à atteindre la limite de la technique d’imagerie du SR. Ainsi, plusieurs solutions ont été investiguées afin d’améliorer la performance du système: la sélection d’une des deux polarisations du SR, la réduction des effets liés à la profondeur de champ par l’utilisation de fentes optiques et l’utilisation d’une longueur d’onde réduite à 250 nm.En parallèle à l’effort de réduction de la diffraction optique, le miroir d’extraction du SR qui s’était avéré être la source principale des aberrations du système a été entièrement reconçu. En effet, la détérioration du miroir a été causée par son couplage EM avec les champs du faisceau, ce qui a conduit à une surchauffe du coating et à sa dégradation. Une nouvelle géométrie de miroir et de son support permettant une douce transition en termes de couplage d’impédance longitudinale dans le beam pipe a été définie et caractérisée par la technique dite du “streched wire”. Egalement, comme méthode alternative à l’imagerie directe, un nouveau moniteur basé sur la technique d’interférométrie à deux fentes du SR, non limité par la diffraction, a également été développé. Le principe de cette méthode est basé sur la relation directe entre la visibilité des franges d’interférence et la taille de faisceau.Comme l’emittance du faisceau est la donnée d’intérêt pour la performance du LHC, il est aussi important de caractériser avec précision l’optique du LHC à la source du SR. Dans ce but, la méthode “K-modulation” a été utilisée pour la première fois au LHC en IR4. Les β ont été mesurés à l’emplacement de tous les quadrupoles et ont été évalués via deux algorithmes de propagation différents au BSRT et au WS. / Measuring the beam transverse emittance is fundamental in every accelerator, in particular for colliders, where its precise determination is essential to maximize the luminosity and thus the performance of the colliding beams.
 Synchrotron Radiation (SR) is a versatile tool for non-destructive beam diagnostics, since its characteristics are closely related to those of the source beam. At CERN, being the only available diagnostics at high beam intensity and energy, SR monitors are exploited as the proton beam size monitor of the two higher energy machines, the Super Proton Synchrotron (SPS) and the Large Hadron Collider (LHC). The thesis work documented in this report focused on the design, development, characterization and optimization of these beam size monitors. Such studies were based on a comprehensive set of theoretical calculations, numerical simulations and experiments.A powerful simulation tool has been developed combining conventional softwares for SR simulation and optics design, thus allowing the description of an SR monitor from its source up to the detector. 
The simulations were confirmed by direct observations, and a detailed performance studies of the operational SR imaging monitor in the LHC, where different techniques for experimentally validating the system were applied, such as cross-calibrations with the wire scanners at low intensity (that are considered as a reference) and direct comparison with beam sizes de-convoluted from the LHC luminosity measurements.In 2015, the beam sizes to be measured with the further increase of the LHC beam energy to 7 TeV will decrease down to ∼190 μm. In these conditions, the SR imaging technique was found at its limits of applicability since the error on the beam size determination is proportional to the ratio of the system resolution and the measured beam size. Therefore, various solutions were probed to improve the system’s performance such as the choice of one light polarization, the reduction of depth of field effect and the reduction of the imaging wavelength down to 250 nm.In parallel to reducing the diffraction contribution to the resolution broadening, the extraction mirror, found as the main sources of aberrations in the system was redesigned. Its failure was caused by the EM coupling with the beam’s fields that led to overheating and deterioration of the coating. A new system’s geometry featuring a smoother transition in the beam pipe was qualified in terms of longitudinal coupling impedance via the stretched wire technique. A comparison with the older system was carried out and resulted in a reduction of the total power dissipated in the extraction system by at least a factor of four.A new, non-diffraction limited, SR-based monitor based on double slit interferometry was designed as well as an alternative method to the direct imaging. Its principle is based on the direct relation between the interferogram fringes visibility and the beam size.Since the beam emittance is the physical quantity of interest in the performance analysis of the LHC, determining the optical functions at the SR monitors is as relevant as measuring the beam size. The “K-modulation” method for the optical function determination was applied for the first time in the LHC IR4, where most of the profile monitors sit. The βs at the quadrupoles were measured and via two different propagation algorithms the βs at the BSRT and the WS were obtained reducing significantly the uncertainty at the monitors location.

Page generated in 0.1206 seconds