21

Dispositivo de extração de cálculos intracoledocianos por inclusão em polímero auto expansível / Device for extraction of choledochal calculi by inclusion in auto expandable polymer

Nascimento Neto, Saturnino Ribeiro do 07 April 2017 (has links)
A cirurgia geral tem experimentado após a década de noventa, com o desenvolvimento da laparoscopia, espetacular melhoria em todos os resultados. Uma menor morbimortalidade se deve ao menor trauma cirúrgico causado pelas cirurgias feitas por pequenos orifícios. O desenvolvimento tecnológico de endoscópios rígidos e flexíveis, propiciou aos médicos um acesso direto às patologias abdominais sem a necessidade de grandes aberturas da cavidade celômica. Assim, houve grande melhoria não somente dos resultados estéticos, mas principalmente na redução de morbidade. Nas cirurgias das vias biliares isso não foi diferente. Com o aprimoramento da técnica cirúrgica laparoscópica, a via de acesso cirúrgico endoscópica passou a ser preferida. Entretanto, a realidade da laparoscopia em muitos locais não se faz presente no tratamento da coledocolitíase, principalmente quando tal patologia é tratada em centros com menor aporte de recursos financeiros. A retirada de cálculos da via biliar principal exige o uso de fibroscópios de alto custo, bem como dispositivos descartáveis de alto valor, forçando o cirurgião desprovido de tais recursos muitas vezes a realizar a cirurgia de maneira convencional ou, no mínimo, aumentado a dificuldade do procedimento por via laparoscópica. Com o intuito de equacionar tal dificuldade, propõe-se com este dispositivo, mais um conceito de abordagem para este problema, inédito, testado em macroambiente, com utilização de cateter contendo balão com polímero autoexpansivo capaz de apreender os cálculos da via biliar principal por meio de inclusão. Utilizando os preceitos da colangiografia per operatória, o novo método propõe a retirada dos cálculos da via biliar principal de maneira indireta com auxílio de métodos de imagem comuns à maioria dos hospitais de média complexidade. / General surgery has experienced after the nineties, with the development of laparoscopy, spectacular improvement in outcomes. Lower morbidity and mortality is due to less surgical trauma caused by surgeries performed by small orifices. The technological development of rigid and flexible endoscopes gave doctors direct access to abdominal pathologies without the need for large openings in the coelomic cavity. Thus, there was a great improvement not only in the aesthetic results, but mainly in the reduction of morbidity. In biliary surgeries this was not different. With the improvement of the laparoscopic surgical technique, the endoscopic cirurgical approach was favored. However, the reality of laparoscopy in many places is not present in the treatment of choledocholithiasis, especially when such pathology is treated in centers with lower financial resources. Removal of stones from the main biliary tract requires the use of high-cost fibroscopes as well as high-value disposable devices, forcing the surgeon devoid of such resources, many times undergoing conventional surgery or at a minimum, increasing the difficulty of the procedure by laparoscopic approach. With the purpose of equating this difficulty, it is proposed with this device, another concept of approach to this problem, novel, tested in macro environment, with the use of balloon catheter containing self expanding polymer capable of grasping the calculi of the common bile duct by inclusion. Using the trans-operative cholangiography precepts, the new method proposes to extract the principal biliary tract calculi indirectly with the help of imaging methods common to the most hospitals.
22

Desenvolvimento de um sistema para medir potência ativa em equipamentos eletrocirúrgicos em tempo real / System development for active power calculation in electrosurgical units

Dums, José Flávio 23 November 2017 (has links)
FUMDES/UNIEDU; FITEJ; / Este trabalho apresenta a concepção de estruturas eletrônicas que podem ser utilizadas para a leitura de tensão e de corrente em conversores estáticos de energia, chaveados ou não, que trabalham em frequências superiores a 100 kHz, em especial as frequências eletrocirúrgicas (300 kHz..5 MHz). Além das estruturas de leitura, também a potência instantânea e a potência ativa são determinadas de forma analógica, possibilitando o futuro desenvolvimento de um sistema de controle da potência ativa de saída de um equipamento eletrocirúrgico. O objetivo é apresentar uma estrutura cuja reatância seja desprezível na faixa de frequências considerada, ou cujo efeito possa ser compensado, possibilitando a criação de circuitos amostradores de sinais complexos, de alta frequência, com um baixo custo de implementação, e usar estas amostras para determinar a potência ativa entregue. Um breve estudo das características reais dos resistores axiais de sinal (resistores com corpo cilíndrico, revestido por um filme de carbono ou filme metálico e com fixação por terminais através de furos na placa de circuito impresso, do inglês Pin Through Hole - PTH), de superfície (Surface Mounted Device - SMD) e resistores de potência de fio também é apresentado. Em seguida, dois modelos simplificados, porém realísticos, são apresentados, sendo um para resistências inferiores a 100 Ohms (Ω) e outro para resistências superiores a 100 Ω. Na sequência, um sistema analógico que realiza a amostragem dos sinais de tensão e de corrente de saída é proposto, bem como um sistema que determina a potência ativa em tempo real. Cada sistema é desenvolvido e testado individualmente, sendo que os resultados validados de um estágio são utilizados para aferir a eficácia do estágio subsequente. Ao final, o conjunto é testado, por meio de uma sequência de ensaios, cujos resultados são analisados e as considerações acerca do sistema como um todo são apresentadas, enfatizando que o erro máximo no cálculo da potência ativa ficou abaixo de 20%, como exige a norma NBR IEC 60601-2-2, assim como o baixo custo de implementação foi alcançado. Por fim, estes resultados mostram uma maneira viável de implementar um sistema de medição de potência ativa para saídas de equipamentos eletrocirúrgicos. / This work presents the design of electronic structures that can be used for voltage and current probing in static power converters, switched or not, which work at frequencies above 100 kHz, in particular electrosurgical frequencies (300 kHz..5 MHz). In addition, also the instantaneous power and the active power are determined analogically, allowing the development of a control system that stabilizes active output power of an electrosurgical unit. The purpose of this work is to find a structure with neglectable reactance in the frequency band considered, or compensate them, creating low cost sampler circuits for complex high frequency signals. A brief study of Pin Through Holes (PTH) signal resistors, Surface Mounted Devices (SMD) signal resistor, and power wire resistors above 100 Ω characteristics is presented. Two realistic simplified models are proposed. One for signal resistances lower than 100 Ω and power wire resistors lower than 100 Ω. Another one for signal resistance greater than 100 Ω. Further, an analog system for reading the output voltage and current are proposed as well as one for real time active power determination. Each system is individually designed and tested. Validated results of one stage are used to assess the effectiveness of the subsequent stage. In the end, the full circuit is tested, and the results are analyzed demonstrating that a lower than 20% error is achieved as well as the low implementation cost. Finally, these results show a way to implement an active power measurement system for electrosurgical units that is unprecedented up to now.
23

Protocolo de verificação do processo de esterilização por vapor de formaldeído / Verification protocol of the formaldehyde steam sterilization process

Borini, Júlio Cesar 08 December 2016 (has links)
Este trabalho apresenta o estudo do processo de esterilização de materiais e instrumentais cirúrgicos em autoclaves que se utilizam do agente esterilizante, o vapor à baixa temperatura de formaldeído. Processo esse utilizado para materiais termosensiveis, ou seja, que não suportam temperaturas superiores a 80°C. Assim objetivo desse trabalho, foi avaliar essa tecnologia de esterilização a baixa temperatura, que já é utilizada há mais de 20 anos em vários países, inclusive aqui no Brasil, porém com pouco detalhes de estudos conclusivos sobre o assunto na literatura nacional e internacional. Este estudo foi baseado nas Normas ABNT NBR 15659 e NF EN ISO 25424 que tratam especificamente dos requisitos, métodos e cuidados na esterilização de vapor a baixa temperatura e formaldeído, implementando um protocolo de verificação para estudo da tecnologia. Para tanto foi elaborada uma metodologia de avaliação, da instalação de esterilizadores que utilizam como agente esterilizante o formaldeído. Na verificação da eficácia da metodologia 3 tipos de equipamentos de esterilização foram testados. Os equipamentos testados são de fabricação brasileira (02 deles) e um de fabricação sueca. Os testes foram feitos em 6 hospitais, onde foram avaliados desde a sua instalação, avaliação dos parâmetros de tempo, temperatura e pressão (com equipamentos calibrados e rastreados pelo INMETRO), avaliação do nível de resíduos no material (com laudos feitos por laboratórios credenciados), uso de indicadores de processo (biológicos e químicos), avaliação ambiental (ar e saída do dejeto para o esgoto), controles de manutenções preventivas e segurança do operador (EPI). Todos os ciclos avaliados apresentaram resultados dentro dos parâmetros mínimos sugerido na Norma ABNT NBR 15659 e NF EN ISO 25424. Concluindo que se seguindo rigorosamente o que pede a Norma e os manuais dos fabricantes dos equipamentos, pode-se perfeitamente obter um processo seguro de esterilização para o Hospital, e atender todos os níveis de segurança tanto para o operador como para o paciente que irá usar o material processado no ciclo de esterilização. / This work presents the study of the sterilization process of surgical materials and instruments in autoclaves using the sterilizing agent, the low temperature vapor of formaldehyde. This process is used for thermosensitive materials, is they do not withstand temperatures above 80 ° C. The objective of this study was to evaluate the low temperature sterilization technology, which has been used for more than 20 years in several countries, including here in Brazil, but with little details of conclusive studies on the subject in the national and international literature. This study was based on the ABNT NBR 15659 and NF EN ISO 25424 standards that specifically deal with the requirements, methods and care in low temperature steam sterilization and formaldehyde, implementing a verification protocol for technology study. For this, an evaluation methodology was elaborated for the installation of sterilizers that use formaldehyde as the sterilizing agent. In the verification of the effectiveness of the methodology 3 types of sterilization equipment were tested. The equipment tested is of Brazilian manufacture (02 of them) and one of Swedish manufacture. The tests were carried out in 6 hospitals, where they were evaluated since its installation, evaluation of parameters of time, temperature and pressure (with equipment calibrated and tracked by INMETRO), evaluation of the level of residues in the material (with reports made by accredited laboratories), use of process indicators (biological and chemical), environmental assessment (air and exits to the sewage), preventive maintenance controls and operator safety (EPI). All the evaluated cycles presented results within the minimum parameters suggested in the Standard ABNT NBR 15659 and NF EN ISO 25424. Concluding that strictly following the norms and the manuals of the equipment manufacturers, it is perfectly possible to obtain a safe process of sterilization To the Hospital, and meet all levels of safety for both the operator and the patient who will use the material processed in the sterilization cycle.
24

Desenvolvimento de um sistema para medir potência ativa em equipamentos eletrocirúrgicos em tempo real / System development for active power calculation in electrosurgical units

Dums, José Flávio 23 November 2017 (has links)
FUMDES/UNIEDU; FITEJ; / Este trabalho apresenta a concepção de estruturas eletrônicas que podem ser utilizadas para a leitura de tensão e de corrente em conversores estáticos de energia, chaveados ou não, que trabalham em frequências superiores a 100 kHz, em especial as frequências eletrocirúrgicas (300 kHz..5 MHz). Além das estruturas de leitura, também a potência instantânea e a potência ativa são determinadas de forma analógica, possibilitando o futuro desenvolvimento de um sistema de controle da potência ativa de saída de um equipamento eletrocirúrgico. O objetivo é apresentar uma estrutura cuja reatância seja desprezível na faixa de frequências considerada, ou cujo efeito possa ser compensado, possibilitando a criação de circuitos amostradores de sinais complexos, de alta frequência, com um baixo custo de implementação, e usar estas amostras para determinar a potência ativa entregue. Um breve estudo das características reais dos resistores axiais de sinal (resistores com corpo cilíndrico, revestido por um filme de carbono ou filme metálico e com fixação por terminais através de furos na placa de circuito impresso, do inglês Pin Through Hole - PTH), de superfície (Surface Mounted Device - SMD) e resistores de potência de fio também é apresentado. Em seguida, dois modelos simplificados, porém realísticos, são apresentados, sendo um para resistências inferiores a 100 Ohms (Ω) e outro para resistências superiores a 100 Ω. Na sequência, um sistema analógico que realiza a amostragem dos sinais de tensão e de corrente de saída é proposto, bem como um sistema que determina a potência ativa em tempo real. Cada sistema é desenvolvido e testado individualmente, sendo que os resultados validados de um estágio são utilizados para aferir a eficácia do estágio subsequente. Ao final, o conjunto é testado, por meio de uma sequência de ensaios, cujos resultados são analisados e as considerações acerca do sistema como um todo são apresentadas, enfatizando que o erro máximo no cálculo da potência ativa ficou abaixo de 20%, como exige a norma NBR IEC 60601-2-2, assim como o baixo custo de implementação foi alcançado. Por fim, estes resultados mostram uma maneira viável de implementar um sistema de medição de potência ativa para saídas de equipamentos eletrocirúrgicos. / This work presents the design of electronic structures that can be used for voltage and current probing in static power converters, switched or not, which work at frequencies above 100 kHz, in particular electrosurgical frequencies (300 kHz..5 MHz). In addition, also the instantaneous power and the active power are determined analogically, allowing the development of a control system that stabilizes active output power of an electrosurgical unit. The purpose of this work is to find a structure with neglectable reactance in the frequency band considered, or compensate them, creating low cost sampler circuits for complex high frequency signals. A brief study of Pin Through Holes (PTH) signal resistors, Surface Mounted Devices (SMD) signal resistor, and power wire resistors above 100 Ω characteristics is presented. Two realistic simplified models are proposed. One for signal resistances lower than 100 Ω and power wire resistors lower than 100 Ω. Another one for signal resistance greater than 100 Ω. Further, an analog system for reading the output voltage and current are proposed as well as one for real time active power determination. Each system is individually designed and tested. Validated results of one stage are used to assess the effectiveness of the subsequent stage. In the end, the full circuit is tested, and the results are analyzed demonstrating that a lower than 20% error is achieved as well as the low implementation cost. Finally, these results show a way to implement an active power measurement system for electrosurgical units that is unprecedented up to now.
25

Protocolo de verificação do processo de esterilização por vapor de formaldeído / Verification protocol of the formaldehyde steam sterilization process

Borini, Júlio Cesar 08 December 2016 (has links)
Este trabalho apresenta o estudo do processo de esterilização de materiais e instrumentais cirúrgicos em autoclaves que se utilizam do agente esterilizante, o vapor à baixa temperatura de formaldeído. Processo esse utilizado para materiais termosensiveis, ou seja, que não suportam temperaturas superiores a 80°C. Assim objetivo desse trabalho, foi avaliar essa tecnologia de esterilização a baixa temperatura, que já é utilizada há mais de 20 anos em vários países, inclusive aqui no Brasil, porém com pouco detalhes de estudos conclusivos sobre o assunto na literatura nacional e internacional. Este estudo foi baseado nas Normas ABNT NBR 15659 e NF EN ISO 25424 que tratam especificamente dos requisitos, métodos e cuidados na esterilização de vapor a baixa temperatura e formaldeído, implementando um protocolo de verificação para estudo da tecnologia. Para tanto foi elaborada uma metodologia de avaliação, da instalação de esterilizadores que utilizam como agente esterilizante o formaldeído. Na verificação da eficácia da metodologia 3 tipos de equipamentos de esterilização foram testados. Os equipamentos testados são de fabricação brasileira (02 deles) e um de fabricação sueca. Os testes foram feitos em 6 hospitais, onde foram avaliados desde a sua instalação, avaliação dos parâmetros de tempo, temperatura e pressão (com equipamentos calibrados e rastreados pelo INMETRO), avaliação do nível de resíduos no material (com laudos feitos por laboratórios credenciados), uso de indicadores de processo (biológicos e químicos), avaliação ambiental (ar e saída do dejeto para o esgoto), controles de manutenções preventivas e segurança do operador (EPI). Todos os ciclos avaliados apresentaram resultados dentro dos parâmetros mínimos sugerido na Norma ABNT NBR 15659 e NF EN ISO 25424. Concluindo que se seguindo rigorosamente o que pede a Norma e os manuais dos fabricantes dos equipamentos, pode-se perfeitamente obter um processo seguro de esterilização para o Hospital, e atender todos os níveis de segurança tanto para o operador como para o paciente que irá usar o material processado no ciclo de esterilização. / This work presents the study of the sterilization process of surgical materials and instruments in autoclaves using the sterilizing agent, the low temperature vapor of formaldehyde. This process is used for thermosensitive materials, is they do not withstand temperatures above 80 ° C. The objective of this study was to evaluate the low temperature sterilization technology, which has been used for more than 20 years in several countries, including here in Brazil, but with little details of conclusive studies on the subject in the national and international literature. This study was based on the ABNT NBR 15659 and NF EN ISO 25424 standards that specifically deal with the requirements, methods and care in low temperature steam sterilization and formaldehyde, implementing a verification protocol for technology study. For this, an evaluation methodology was elaborated for the installation of sterilizers that use formaldehyde as the sterilizing agent. In the verification of the effectiveness of the methodology 3 types of sterilization equipment were tested. The equipment tested is of Brazilian manufacture (02 of them) and one of Swedish manufacture. The tests were carried out in 6 hospitals, where they were evaluated since its installation, evaluation of parameters of time, temperature and pressure (with equipment calibrated and tracked by INMETRO), evaluation of the level of residues in the material (with reports made by accredited laboratories), use of process indicators (biological and chemical), environmental assessment (air and exits to the sewage), preventive maintenance controls and operator safety (EPI). All the evaluated cycles presented results within the minimum parameters suggested in the Standard ABNT NBR 15659 and NF EN ISO 25424. Concluding that strictly following the norms and the manuals of the equipment manufacturers, it is perfectly possible to obtain a safe process of sterilization To the Hospital, and meet all levels of safety for both the operator and the patient who will use the material processed in the sterilization cycle.