• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • No language data
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An Analytical Study on the Behavior of Reinforced Concrete Interior Beam-Column Joints

Xing, Chenxi 06 August 2019 (has links)
Reinforced concrete (RC) moment frame structures make up a notable proportion of buildings in earthquake-prone regions in the United States and throughout the world. The beam-column (BC) joints are the most crucial regions in a RC moment frame structure as any deterioration of strength and/or stiffness in these areas can lead to global collapse of the structure. Thus, accurate simulations of the joint behavior are important for assessment of the local and global performance of both one-way and two-way interior BC joints. Such simulations can be used to study the flexural-shear-bond interaction, the failure modes, and sensitivity of various parameters of structural elements. Most of the existing analytical approaches for interior BC joints have either failed to account for the cyclic bond-slip behavior and the triaxial compressive state of confined concrete in the joint correctly or require so many calibrations on parameters as to render them impractical. The core motivation for this study is the need to develop robust models to test current design recommendations for 3D beam-column-slab subassemblies subjected to large drifts. The present study aims to first evaluate the flexural-shear-bond interactive behavior of two-way beam-column-slab interior connections by both finite element and nonlinear truss methodologies. The local performance such as bond-slip and strain history of reinforcing steel are compared with the experimental results for the first time. The reliability of applied finite element approach is evaluated against a series of one-way interior BC joints and a two-way interior beam-column-slab joint. The accuracy and efficiency of the nonlinear truss methodology is also evaluated by the same series of joints. Results show good agreement for finite element method against both global and local response, including hysteretic curve, local bond-slip development and beam longitudinal bar stress/strain distributions. The nonlinear truss model is also capable in obtaining satisfactory global response, especially in capturing large shear cracks. A parametric study is exhibited for a prototype two-way interior beam-column-slab joint described in an example to ACI 352R-02, to quantify several non-consensus topics in the design of interior BC connections, such as the joint shear force subjected to bidirectional cyclic loading, the development of bond-slip behavior, and the failure modes of two-way interior joints with slab. Results from connections with different levels of joint shear force subjected to unidirectional loading show that meeting the requirements from ACI 352 is essential to maintain the force transfer mechanism and the integrity of the joint. The connections achieved satisfactory performance under unidirectional loading, while the bidirectional monotonic loading decreases the joint shear force calculated by ACI 352 by 10%~26% based on current results. Poorer performance is obtained for wider beams and connections fail by shear in the joint rather than bond-slip behavior when subjected to bidirectional cyclic loading. In general, the study indicates that the ACI352-02 design methodology generally results in satisfactory performance when applied to 2D joints (planar) under monotonic and cyclic loads. Less satisfactory performance was found for cases of 3D joints with slabs. / Doctor of Philosophy / Reinforced concrete (RC) moment frames are one of the most popular structure types because of their economical construction and adaptable spaces. Moment frames consist of grid-like assemblages of vertical columns and horizontal beams joined by cruciform connections commonly labelled as beam-column joints. Because of the regularity of the grid and the ability to have long column spacing, moment frames are easy to form and cast and result in wide open bays that can be adapted and readapted to many uses. In RC structures, steel bars embedded in the concrete are used to take tensile forces, as concrete is relatively weak when loaded in tension. Forces are transferred between the steel and concrete components by so-called “bond” forces at the perimeter of the bars. The proper modeling of the behavior of bond forces inside the beam-column joints of reinforced concrete moment frames is the primary objective of this dissertation. Reinforced concrete moment frames constitute a notable proportion of the existing buildings in earthquake-prone regions in the United States and throughout the world. The beam-column joints are the most crucial elements in a RC moment frame structure as any deterioration of strength and/or stiffness in these areas can lead to global collapse of the structure. Physical experimentation is the most reliable means of studying the performance of beam-column joints. However, experimental tests are expensive and time-consuming. This is why computational simulation must always be used as a supplemental tool. Accurate simulations of the behavior of beam-column joints is important for assessment of the local and global behavior of beam-column joints. However, most of the existing analytical approaches for interior beam-column joints have either failed to account for the bond-slip behavior and the triaxial compressive state of confined concrete in the joint correctly or require so many calibration parameters as to render them impractical. The present study aims to provide reliable numerical methods for evaluating the behavior of two-way beam-column-slab interior joints. Two methods are developed. The v first method is a complex finite element model in which the beam-column joint is subdivided into many small 3D parts with the geometrical and material characteristics of each part carefully defined. Since the number of parts may be in the hundreds of thousands and the geometry and material behavior highly non-linear, setting up the problem and its solution of this problem requires large effort on the part of the structural engineer and long computation times in supercomputers. Finite element models of this type are generally accurate and are used to calibrate simpler models. The second method developed herein is a nonlinear truss analogy model. In this case the structure is modelled as nonlinear truss elements, or elements carrying only axial forces. When properly calibrated, this method can produce excellent results especially in capturing large shear cracks. To evaluate the accuracy and to quantify the current seismic design procedure for beam-column joints, a prototype two-way interior beam-column-slab joint described in an example to ACI 352R-02, the current design guide used for these elements in the USA, is analytically studied by the finite element methodology. The study indicates that the ACI352-02 design methodology generally results in satisfactory performance when applied to one-way (planar) joints under monotonic and cyclic loads. Less satisfactory performance was found for cases of three-dimensional (3D) joints with slabs.

Page generated in 0.0543 seconds