Spelling suggestions: "subject:"intraradicular retained"" "subject:"intraradicular retain""
1 |
Estudo comparativo entre diferentes cimentos endodônticos em relação à resistência de união do conjunto cimento resinoso/pino de fibra de vidro à dentina radicular / Comparative study between different endodontic sealers in relation to the bond strength of the resin cement / fiberglass post complex to the root dentinSoares, Isadora Mello Vilarinho 03 August 2018 (has links)
O objetivo do estudo foi avaliar, comparativamente, a influência do cimento biocerâmico EndoSequence BC a diferentes cimentos endodônticos sobre a resistência de união do conjuno cimento resinoso/pino de fibra de vidro à dentina radicular. Setenta e dois dentes caninos selecionados tiveram a coroa seccionada transversalmente e o remanescente radicular padronizado em 17mm. O canal radicular foi preparado com Reciproc R50 e NaOCl 1%. Os espécimes foram distribuídos conforme o cimento obturador utilizado (n=12): G1-controle (sem cimento); G2- óxido de zinco e eugenol (EndoFill) G3- hidróxido de cálcio (Sealapex); G4- resina epóxi (AHPlus); G5-resina epóxi e hidróxido de cálcio (Sealer Plus) e G6- biocerâmico (EndoSequence BC). Decorridas 48h da obturação, as raízes foram desobturadas e preparadas para receber o pino de fibra de vidro. Após secagem do canal, os pinos foram cimentados com Panavia F 2.0. Dez raízes de cada grupo foram seccionadas transversalmente para obtenção dos slices. O primeiro slice de cada terço foi submetido ao teste de resistência de união (push-out) e padrão de falha. No segundo slice foi avaliada a interface adesiva dentina/cimento resinoso, por meio de microscopia de varredura confocal a laser (MVCL). Dois espécimes de cada grupo não tiveram o pino cimentado no canal radicular e foram destinados à microscopia eletrônica de varredura para observação de remanescente de material obturador na superfície dentinária. Os dados referentes à resistência de união foram submetidos ao teste Shapiro-Wilk, seguido de ANOVA two way. Os dados referentes à MVCL foram analisados pelo teste Kruskal-Wallis seguido pelo teste Dunn ( = 5%). Os grupos controle e AHPLus apresentaram os maiores valores de RU (p<0,05). Os cimentos EndoSequence BC, Sealer Plus e Sealapex apresentaram os valores intermediários de RU, sem diferença estatística entre eles. O cimento EndoFill apresentou os menores valores de RU com diferença estatisticamente significante em relação aos demais grupos (p<0,05). Quanto aos terços radiculares, os maiores valores de RU foram observados no terço cervical (p<0,05). As imagens de MEV demonstraram no geral, presença de poucos remanescentes de material obturador na superfície radicular em todos os grupos. Quanto a análise da interface cimento resinoso/dentina, a maioria dos grupos apresentou adaptação razoável, com exceção do EndoFill. Concluiu-se que os cimentos endodônticos Endosequence BC, Sealapex, Sealer Plus e EndoFill influenciaram negativamente a RU do conjunto pino/cimento resinoso à dentina radicular / The aim of this study was to compare the influence of EndoSequence BC bioceramic sealer on the bond strength (BS) of resin cement/fiber post in root canals filled with different sealers. The coronary of seventy-two canines were removed and the root length standardized at 17mm. The root canal was prepared with Reciproc R50 and 1% NaOCl. The specimens were distributed according to the filling material used (n=12): G1- control (no sealer); G2- zinc oxide and eugenol (EndoFill) G3- calcium hydroxide (Sealapex); G4- epoxy resin (AHPlus); G5- epoxy resin and calcium hydroxide (Sealer Plus) and G6- bioceramic (EndoSequence BC). Later forthy eight hours, the roots were prepared to insert the fiberpost. Fiberposts were attached with Panavia F 2.0. Ten roots of each group were sectioned transversely, obtaining slices of cervical, medium and apical root canal thirds. The BS of the first slice of each third was evaluated by push-out test and failures was analyzed by stereo microscope. The interface between dentin wall/resin cement of the second slice was evaluated by confocal laser microscopy (CLM). Two specimens from group were not restored with fiberpost, and assigned to scanning electron microscopy (SEM) to analyze the remaining material on the dentin surface. Data on the bond strength were submitted to the Shapiro-Wilk test, followed by two way ANOVA. The CLM data were submitted to the Kruskal-Wallis and Dunn tests ( = 5%). The control and AHPLus groups had the highest RU values (p <0.05). The EndoSequence BC, Sealer Plus and Sealapex sealers presented the intermediate values of RU, with no statistical difference between them. EndoFill sealer presented the lowest values of RU with a statistically significant difference in relation to the other groups (p <0.05). Regarding root thirds, the highest BS values were observed in cervical third (p <0.05). SEM images showed presence of few remaning filling material on the root surface in all groups. Regarding the dentine/resin cement interfaces analyzes most of the groups presented average adaptation, unless the G2. It was concluded that Endosequence BC, Sealapex, Sealer Plus and EndoFill endodontic sealers poor influenced the BS of the fiber post/resin cement in root canal dentin
|
2 |
Análise da performance mecânico-estrutural e resistência de união de diferentes técnicas de utilização de pinos de fibra de vidro. /Hoshino, Isis Almela Endo January 2019 (has links)
Orientador: Rodolfo Bruniera Anchieta / Resumo: O objetivo deste trabalho foi avaliar “in vitro” e “in silico” a integridade estrutural da interface de cimentação, o comportamento biomecânico, e a resistência de união da interface dentina/cimento de diferentes técnicas de cimentação de pinos de fibra de vidro (PFV) em canais amplos. Para tanto, foram utilizados 33 incisivos bovinos. Após o tratamento endodôntico, os espécimes foram divididos aleatoriamente em três grupos (n=11): PCN- Pino convencional cimentado em dente com conduto normal; PCA- Pino convencional cimentado em dente com conduto amplo; PAA- Pino anatômico cimentado em dente com conduto amplo. Em seguida, foram executados os preparos intrarradiculares de acordo com cada grupo com brocas pré-estabelecidas, tratamento de superfície dos PFV (WhitePost nº3 DC, FGM) e cimentação dos mesmos com o cimento resinoso autoadesivo (Rely X U200, 3M ESPE). Então, 6 espécimes de cada grupo foram submetidos ao escaneamento em um microtomógrafo de alta resolução (SkyScan 1272) para avaliação da integridade, volume e presença de bolhas na interface de cimentação. Posteriormente, com base nos dados do µCT e imagens de microscopia (n=1), dois modelos tridimensionais de cada grupo foram confeccionados para a análise de elementos finitos, sendo que o primeiro foi considerado ideal (G1, G3 e G5), sem defeitos na interface, e o segundo continha as condições encontradas pela análise de µCT(G2, G4 e G6). Após o envelhecimento em estufa por 7 meses, todos os espécimes foram submetidos a... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate “in vitro” and “in silico” the structural integrity of the cementation interface, the biomechanical behavior and the bond strength of different fiberglass post cementation techniques in flared root canal. To this end, 33 bovine incisors were used. After the endodontic treatment, the specimens were randomly divided into three groups (n = 11): PCN - conventional post cemented in tooth with normal canal lumen; PCA- Conventional fiberglass post cemented in flared root canal; PAA- Fiberglass post relined with composite resin and cemented in flared root canal; Then, the intra-radicular preparations were performed according to each group with pre-established drills, surface treatment of PFV (WhitePost Nº. 3DC, FGM) and cementation with self-adhesive resin cement (Rely X U200, 3M ESPE). Then, 6 specimens from each group were submitted to scanning in a high resolution microtomograph (SkyScan 1272) to evaluate the integrity, volume and presence of bubbles at the cementation interface. Then, based on the μCT data and the microscopic images (n = 1), two three-dimensional models of each group were made to analyze finite elements, the first one being considered ideal (G1, G3 and G5), without interface defects and the second contained the conditions found by μCT analysis (G2, G4 and G6). After being stored for 7 months, all specimens were submitted to the pushout bond strength test (n = 10). Data were submitted to ANOVA with repeated measures and ... (Complete abstract click electronic access below) / Mestre
|
Page generated in 0.0936 seconds