• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análisis de la resistencia unitaria lateral última de micropilotes inyectados en arcillas saturadas de Cusco a través de pruebas de carga / Analysis of the ultimate lateral unit resistance of micropiles injected in saturated clays of Cusco through load tests

Molina Lovatón, Rodrigo 15 August 2019 (has links)
La presente investigación tiene por objetivo determinar la resistencia unitaria lateral última del bulbo de micropilotes ejecutados mediante inyección repetitiva (IR) a partir de pruebas de carga, en suelos arcillosos saturados del distrito de San Sebastián – Cusco, 2016. El estudio fue elaborado a partir de la información brindada por empresas especializadas en estudio de suelos, ejecución de micropilotes y pruebas de carga. Se analizaron ocho de catorce pruebas de carga realizadas en total, porque estas alcanzaron la falla. En todas las pruebas se utilizó un manómetro que midió la fuerza ejercida por cuatro gatos hidráulicos, tal como indica la norma ASTM D1143. Para obtener la resistencia unitaria lateral última del bulbo (qs), primero, se determinó la carga última, luego, a este valor se restó el aporte de carga lateral en la longitud no inyectada, y ese resultado, fue dividido entre el área lateral de contacto entre el bulbo y el suelo circundante. Se determinó que los micropilotes alcanzaron cargas últimas desde 39.40 hasta 101.30 toneladas, además, las áreas de contacto entre el bulbo y el suelo se estimaron entre 16.51 y 38.46 m2, a partir de ello, se determinó que las resistencias unitarias laterales últimas varían entre 1.29 y 3.45 toneladas por metro cuadrado. La finalidad de esta investigación es contribuir a la mejor estimación de la resistencia unitaria lateral última del bulbo de micropilotes tipo IR en arcillas saturadas con número de SPT entre 19 y 28. / The objective of this research is to determine the ultimate lateral unitary resistance of the bulb of micropiles executed by repetitive injection (RI) based on load tests in saturated clay soils on the district of San Sebastian - Cusco, 2016. The study was prepared based on the information provided by companies specialized in soil studies, micropiles and load testing. Eight of fourteen load tests performed in total were analyzed, because they reached failure. In all tests, a manometer was used that measured the force exerted by four hydraulic jacks, as indicated by ASTM D1143. To obtain the last lateral unitary resistance of the bulb (qs), first, the last load was determined, then, at this value, the contribution of lateral load in the non-injected length was subtracted, and that result was divided between the lateral area of contact between the bulb and the surrounding soil. It was determined that the micropiles reached final loads from 39.40 to 101.30 tons, in addition, the contact areas between the bulb and the soil were estimated between 16.51 and 38.46 m2, from this, it was determined that the ultimate lateral unit resistances vary between 1.29 and 3.45 tons per square meter. The purpose of this research is to contribute to the best estimate of the ultimate lateral unitary resistance of the RI-type micropile bulb in saturated clays with SPT number between 10 and 32. / Tesis

Page generated in 0.0782 seconds