• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 4
  • Tagged with
  • 11
  • 11
  • 11
  • 5
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Fabrication and use of new solid state phosphate ion selective electrodes for monitoring phosphorylation and dephosphorylation reactions

Enemchukwu, Emeka Martin 06 1900 (has links)
Highly selective and sensitive phosphate sensors have been fabricated by constructing a solid membrane disk consisting of variable mixtures of aluminium powder (Al), aluminium phosphate (AlPO4) and powdered copper (Cu). Both binary and ternary electrode systems are produced depending on their composition. The ternary membranes exhibit greater selectivity over a wide range of concentrations. The ternary electrode with the composition 25% AlPO4, 25% Cu and 50% Al was selected as our preferred electrode. The newly fabricated ternary membrane phosphate selective electrodes exhibited linear potential response in the concentration range of 1.0 × 10−6 to 1.0 × 10−1 mol L−1. The electrodes also exhibit a fast response time of <60 s. Their detection limit is 1.0 × 10−6 mol L−1. The unique feature of the described electrodes is their ability to maintain a steady and reproducible response in the absence of an ionic strength control. The electrodes have a long lifetime and can be stored in air when not in use. The selectivity of the new phosphate selective electrodes with respect to other common ions is excellent. The results obtained provide further insight into the working principles of the newly fabricated phosphate selective electrodes. Dephosphorylation and phosphorylation reactions were monitored using the preferred phosphate selective electrode. The following reactions were studied and inferences drawn; (a) the reactions between *[{CoN4(OH)(OH2)}]2+ and *[OH(PO2O)]2- for 1:1, 2:1 and 3:1 *[{CoN4(OH)(OH2)}]2+ to *[OH(PO2O)]2- ratios.(b) the reactions between *[{CoN4(OH)(OH2)}]2+ and *[O2NC6H4PO2(O)(OH)]- for 1:1, 2:1 and 3:1 *[{CoN4(OH)(OH2)}]2+ to *[O2NC6H4PO2(O)(OH)]- ratios. (c) the reactions between *[{CoN4(OH)(OH2)}]2+ and *[(OH)2(PO2)2O]2- for 1:1, 2:1 and 3:1 [{CoN4(OH)(OH2)}]2+ to *[(OH)2(PO2)2O]2- ratios, and (d) the reactions between *[{CoN4(OH)(OH2)}]2+ and *[(OH)2(PO2)3O2]3- for the 1:1, 2:1 and 3:1 [{CoN4(OH)(OH2)}]2+ to *[(OH)2(PO2)3O2]3- ratios. Further insight into dephosphorylation and phosphorylation reactions is unravelled by the novel phosphate selective electrode monitoring. *For clarity of the complexes utilized, see chapter 4, table 4.1. KEY WORDS; Dephosphorylation, phosphorylation, ion selective electrodes, phosphate ion selective electrode, decontamination, electromotive force, potential difference, activity, concentration, selectivity coefficient, calibration, ionic strength, hydrolysis, inorganic phosphates, nitrophenylphosphate, pyrophosphate, tripolyphosphate, organophosphate esters. / Chemistry / D. Phil (Chemistry)

Page generated in 0.0129 seconds