21

Estabelecimento de um novo método de calibração de câmaras de ionização tipo lápis para dosimetria em feixes de tomografia computadorizada / Establishment of a new calibration method of pencil ionization chamber for dosimetry in computed tomography

Dias, Daniel Menezes 15 December 2010 (has links)
As câmaras de ionização tipo lápis são utilizadas para dosimetria de feixes em equipamentos de tomografia computadorizada (CT). Neste estudo foi estabelecida uma nova metodologia de calibração destas câmaras, visando a adequação do Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI) aos atuais padrões metrológicos internacionais que tratam dos procedimentos específicos para calibração das câmaras utilizadas em CT. Primeiramente partiu-se da implantação das novas qualidades de radiação padrão RQT, que simulam feixes não atenuados usados para aplicações em CT, de acordo com a IEC 61267 da International Electrotechnical Commission (IEC). Após o estabelecimento dos campos padrões de radiação, foi implantada a metodologia de calibração específica para câmaras lápis segundo o Technical Report Series No. 457, da International Atomic Energy Agency (IAEA), que descreve as particularidades do procedimento a ser seguido pelos Laboratórios de Dosimetria Padrão Secundário (SSDLs) em termos de colimação e posicionamento em relação ao feixe de radiação. Inicialmente, foram realizadas medições de PPV (kV) e determinação das filtrações adicionais de cobre por meio dos valores de camada semi-redutora (CSR) recomendados pela norma IEC 61267, para que as qualidades de radiação de referência: RQT 8, RQT 9 e RQT 10 fossem implantadas. Para os filtros adicionais, foram utilizados alumínio e cobre de alta pureza (maior ou igual a 99,9%). Uma metodologia alternativa para determinar as filtrações adicionais também foi utilizada, através da qual se encontrou diretamente as RQTs em espessuras de filtros de cobre equivalente ao conjunto RQR (Al) + Filtração Adicional (Cu), sendo esta uma opção quando não se têm implantadas as RQRs. Com a implantação desta nova metodologia de calibração das câmaras de ionização tipo lápis, o LCI está pronto para calibrar estes instrumentos de acordo com as recentes recomendações internacionais. Permitindo assim uma melhoria na rastreabilidade das calibrações, como também na qualidade dos serviços metrológicos que o IPEN oferece para todo o País. / Pencil ionization chambers are used for beam dosimetry in computed tomography equipment (CT). In this study, a new calibration methodology was established, in order to make the Calibration Laboratory of Instituto de Pesquisas Energéticas e Nucleares (LCI) suitable to international metrological standards, dealing with specific procedures for calibration of these chambers used in CT. Firstly, the setup for the new RQT radiation qualities was mounted, in agreement with IEC61267 from the International Electrotechnical Commission (IEC). After the establishment of these radiation qualities, a specific calibration methodology for pencil ionization chambers was set, according to Technical Report Series No. 457, from the International Atomic Energy Agency (IAEA), which describes particularities of the procedure to be followed by the Secondary Standard Dosimetry Laboratories (SSDLs), concerning to collimation and positioning related to the radiation beam. Initially, PPV (kV) measurements and the determination of copper additional filtrations were carried out, measuring the half value layers (HVL) recommended by the IEC 61267 standard, after that the RQT 8, RQT 9 and RQT 10 radiation quality references were established. For additional filters, aluminum and copper of high purity (around 99.9%) were used. RQTs in thickness of copper filters equivalent to the set RQR (Al) + Additional Filtration (Cu) was directly found by an alternative methodology used to determine additional filtrations, which is a good option when RQRs have not the possibility of be setting up. With the establishment of this new methodology for the ionization pencil chambers calibration, the LCI is ready to calibrate these instruments according to the most recent international standards. Therefore, an improvement in calibration traceability, as well as in metrological services offered by IPEN to all Brazil is achieved.
22

Estabelecimento de um novo método de calibração de câmaras de ionização tipo lápis para dosimetria em feixes de tomografia computadorizada / Establishment of a new calibration method of pencil ionization chamber for dosimetry in computed tomography

Daniel Menezes Dias 15 December 2010 (has links)
As câmaras de ionização tipo lápis são utilizadas para dosimetria de feixes em equipamentos de tomografia computadorizada (CT). Neste estudo foi estabelecida uma nova metodologia de calibração destas câmaras, visando a adequação do Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI) aos atuais padrões metrológicos internacionais que tratam dos procedimentos específicos para calibração das câmaras utilizadas em CT. Primeiramente partiu-se da implantação das novas qualidades de radiação padrão RQT, que simulam feixes não atenuados usados para aplicações em CT, de acordo com a IEC 61267 da International Electrotechnical Commission (IEC). Após o estabelecimento dos campos padrões de radiação, foi implantada a metodologia de calibração específica para câmaras lápis segundo o Technical Report Series No. 457, da International Atomic Energy Agency (IAEA), que descreve as particularidades do procedimento a ser seguido pelos Laboratórios de Dosimetria Padrão Secundário (SSDLs) em termos de colimação e posicionamento em relação ao feixe de radiação. Inicialmente, foram realizadas medições de PPV (kV) e determinação das filtrações adicionais de cobre por meio dos valores de camada semi-redutora (CSR) recomendados pela norma IEC 61267, para que as qualidades de radiação de referência: RQT 8, RQT 9 e RQT 10 fossem implantadas. Para os filtros adicionais, foram utilizados alumínio e cobre de alta pureza (maior ou igual a 99,9%). Uma metodologia alternativa para determinar as filtrações adicionais também foi utilizada, através da qual se encontrou diretamente as RQTs em espessuras de filtros de cobre equivalente ao conjunto RQR (Al) + Filtração Adicional (Cu), sendo esta uma opção quando não se têm implantadas as RQRs. Com a implantação desta nova metodologia de calibração das câmaras de ionização tipo lápis, o LCI está pronto para calibrar estes instrumentos de acordo com as recentes recomendações internacionais. Permitindo assim uma melhoria na rastreabilidade das calibrações, como também na qualidade dos serviços metrológicos que o IPEN oferece para todo o País. / Pencil ionization chambers are used for beam dosimetry in computed tomography equipment (CT). In this study, a new calibration methodology was established, in order to make the Calibration Laboratory of Instituto de Pesquisas Energéticas e Nucleares (LCI) suitable to international metrological standards, dealing with specific procedures for calibration of these chambers used in CT. Firstly, the setup for the new RQT radiation qualities was mounted, in agreement with IEC61267 from the International Electrotechnical Commission (IEC). After the establishment of these radiation qualities, a specific calibration methodology for pencil ionization chambers was set, according to Technical Report Series No. 457, from the International Atomic Energy Agency (IAEA), which describes particularities of the procedure to be followed by the Secondary Standard Dosimetry Laboratories (SSDLs), concerning to collimation and positioning related to the radiation beam. Initially, PPV (kV) measurements and the determination of copper additional filtrations were carried out, measuring the half value layers (HVL) recommended by the IEC 61267 standard, after that the RQT 8, RQT 9 and RQT 10 radiation quality references were established. For additional filters, aluminum and copper of high purity (around 99.9%) were used. RQTs in thickness of copper filters equivalent to the set RQR (Al) + Additional Filtration (Cu) was directly found by an alternative methodology used to determine additional filtrations, which is a good option when RQRs have not the possibility of be setting up. With the establishment of this new methodology for the ionization pencil chambers calibration, the LCI is ready to calibrate these instruments according to the most recent international standards. Therefore, an improvement in calibration traceability, as well as in metrological services offered by IPEN to all Brazil is achieved.
23

Projeto, construção e caracterização de câmaras de ionização para utilização como sistemas padrões em feixes de radiação X e gama / Project, construction and characterization of ionization chambers for use as standard systems in X and gamma radiation beams

Ana Paula Perini 05 November 2013 (has links)
As câmaras de ionização apresentam várias vantagens em comparação com os demais dosímetros: facilidade de uso, dependência energética pequena e excelente precisão. Estas vantagens aliadas ao grande número de exames de radiodiagnóstico e tratamentos radioterápicos motivaram o desenvolvimento deste plano de doutorado. Neste projeto foram desenvolvidas e caracterizadas câmaras de ionização para aplicação em dosimetria de feixes de radiodiagnóstico e em terapia, com boa precisão e desempenho nos testes de caracterização dentro dos limites recomendados internacionalmente. Elas foram construídas de maneira simples com materiais nacionais de baixo custo, para que elas possam ser reproduzidas e aplicadas em laboratórios de calibração. Os projetos das câmaras de ionização desenvolvidas e caracterizadas neste projeto apresentam diferenças relacionadas ao material e configuração geométrica em comparação às câmaras de ionização comerciais disponíveis no mercado. Além do desenvolvimento de câmaras de ionização para serem utilizadas em feixes padrões de radiação X como padrões de trabalho, neste projeto também foram desenvolvidas e caracterizadas experimentalmente e por simulação de Monte Carlo duas câmaras de ionização cavitárias de grafite de placas paralelas, que foram caracterizadas como sistemas padrões de referência para determinação da taxa de kerma no ar de fontes de radiação gama. Comparando a taxa de kerma no ar determinada com o padrão de referência do Laboratório de Calibração do IPEN, uma câmara de ionização tipo Farmer, com os valores de taxa de kerma no ar obtidos com as câmaras de ionização de grafite, as máximas diferenças obtidas foram de apenas 1,7% e 1,2% para as câmaras de ionização de grafite G1 e G2, respectivamente. Além disso, estas câmaras de ionização apresentaram fatores de correção próximos de 1,000, que é o ideal para uma câmara de ionização ser caracterizada como um sistema de referência. / Ionization chambers present some advantages in relation to other dosimeters: easiness of handling, low energy dependence and high precision. The advantages associated to ionization chambers and the large number of diagnostic radiology exams and therapeutic treatments motivated the development of this project. In this project ionization chambers were developed and characterized to be applied in diagnostic radiology and therapy beam dosimetry, with high precision and performance, in compliance with international recommendations. They were assembled in a simple way, utilizing low-cost national materials, so they can be reproduced and applied at calibration laboratories. The project of these ionization chambers presents some differences in relation to commercial ionization chambers, as the materials utilized and geometrical arrangements. Besides the development of the ionization chambers to be utilized in standard X-ray beam dosimetry as work standard systems, two graphite parallel-plate ionization chambers were developed and characterized to be applied as reference standard systems for determining the air kerma rates of gamma radiation sources. Comparing the air kerma rates determined with the reference standard of the Calibration Laboratory of IPEN, a Farmer ionization chamber, with the values of the air kerma rates obtained with the graphite ionization chambers, the maximum differences obtained were only 1.7% and 1.2% for the G1 and G2 graphite ionization chambers, respectively. Moreover, these ionization chambers presented correction factors close to 1.000, which is ideal for an ionization chamber be characterized as a reference standard system.
24

Estabelecimento de um sistema padrão primário para raios X de energias baixas com uma câmara de ionização de ar livre / Establishment a primary standard system for low energy X-rays using a free air ionization chamber

Natália Fiorini da Silva 22 March 2016 (has links)
Neste trabalho foi estabelecido um sistema padrão primário para raios X de energias baixas (10 kV a 50 kV), utilizando uma câmara de ionização de ar livre de cilindros concêntricos da marca Victoreen (modelo 481-5) no Laboratório de Calibração de Instrumentos (LCI) do Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP). Para isso foi desenvolvido um novo protocolo de alinhamento da câmara de ionização no sistema de radiação e foi feita uma modificação no suporte dos micrômetros utilizados para o movimento dos cilindros internos. Os resultados obtidos nos testes de estabilidade e de caracterização ficaram dentro dos limites estabelecidos pelas normas IEC 61674 e IEC 60731. Foram determinados também os fatores de correção para atenuação de fótons no ar, transmissão e espalhamento no diafragma, espalhamento e fluorescência, e recombinação iônica. Esses valores foram comparados com os valores obtidos pelo laboratório padrão primário alemão,Physikalisch-Technische Bundesanstalt (PTB), mostrando boa concordância. Por último, foi determinado o valor absoluto da grandeza taxa de kerma no ar para as qualidades padronizadas de mamografia de feixes diretos WMV28 e WMV35 e feixes atenuados WMH28 e WMH35; os resultados são compatíveis, com diferença máxima de 3,8% com os valores obtidos utilizando o sistema padrão secundário do LCI. / In this work a primary standard system was established for low energy X-rays (10 kV to 50 kV), using a free air ionization chamber with concentric cylinders, Victoreen (Model 481-5), at the Calibration Laboratory of Instruments (LCI) of the Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP). For this, a new ionization chamber alignment protocol was developed for the radiation system and a modification on the micrometer housing used for the movement of the internal cylinders was made. The results obtained for the stability and characterization tests showed to be within the limits established by the standards IEC 61674 and IEC 60731. The correction factors for photon attenuation in the air, transmission and scattering in the diaphragm, scattering and fluorescence and ion recombination were also determined. These values were compared with those obtained by the German primary standard laboratory, Physikalisch-Technische Bundesanstalt (PTB), showing good agreement. Finally, the absolute values of the quantity air kerma rate for the standard qualities direct beams MWV28 and WMV35 and the attenuated beams WMH28 and WMH35 were determined; the results are in agreement, with a maximum difference of 3,8% with the values obtained using the secondary standard system of LCI.
25

Projeto, construção e caracterização de câmaras de ionização para utilização como sistemas padrões em feixes de radiação X e gama / Project, construction and characterization of ionization chambers for use as standard systems in X and gamma radiation beams

Perini, Ana Paula 05 November 2013 (has links)
As câmaras de ionização apresentam várias vantagens em comparação com os demais dosímetros: facilidade de uso, dependência energética pequena e excelente precisão. Estas vantagens aliadas ao grande número de exames de radiodiagnóstico e tratamentos radioterápicos motivaram o desenvolvimento deste plano de doutorado. Neste projeto foram desenvolvidas e caracterizadas câmaras de ionização para aplicação em dosimetria de feixes de radiodiagnóstico e em terapia, com boa precisão e desempenho nos testes de caracterização dentro dos limites recomendados internacionalmente. Elas foram construídas de maneira simples com materiais nacionais de baixo custo, para que elas possam ser reproduzidas e aplicadas em laboratórios de calibração. Os projetos das câmaras de ionização desenvolvidas e caracterizadas neste projeto apresentam diferenças relacionadas ao material e configuração geométrica em comparação às câmaras de ionização comerciais disponíveis no mercado. Além do desenvolvimento de câmaras de ionização para serem utilizadas em feixes padrões de radiação X como padrões de trabalho, neste projeto também foram desenvolvidas e caracterizadas experimentalmente e por simulação de Monte Carlo duas câmaras de ionização cavitárias de grafite de placas paralelas, que foram caracterizadas como sistemas padrões de referência para determinação da taxa de kerma no ar de fontes de radiação gama. Comparando a taxa de kerma no ar determinada com o padrão de referência do Laboratório de Calibração do IPEN, uma câmara de ionização tipo Farmer, com os valores de taxa de kerma no ar obtidos com as câmaras de ionização de grafite, as máximas diferenças obtidas foram de apenas 1,7% e 1,2% para as câmaras de ionização de grafite G1 e G2, respectivamente. Além disso, estas câmaras de ionização apresentaram fatores de correção próximos de 1,000, que é o ideal para uma câmara de ionização ser caracterizada como um sistema de referência. / Ionization chambers present some advantages in relation to other dosimeters: easiness of handling, low energy dependence and high precision. The advantages associated to ionization chambers and the large number of diagnostic radiology exams and therapeutic treatments motivated the development of this project. In this project ionization chambers were developed and characterized to be applied in diagnostic radiology and therapy beam dosimetry, with high precision and performance, in compliance with international recommendations. They were assembled in a simple way, utilizing low-cost national materials, so they can be reproduced and applied at calibration laboratories. The project of these ionization chambers presents some differences in relation to commercial ionization chambers, as the materials utilized and geometrical arrangements. Besides the development of the ionization chambers to be utilized in standard X-ray beam dosimetry as work standard systems, two graphite parallel-plate ionization chambers were developed and characterized to be applied as reference standard systems for determining the air kerma rates of gamma radiation sources. Comparing the air kerma rates determined with the reference standard of the Calibration Laboratory of IPEN, a Farmer ionization chamber, with the values of the air kerma rates obtained with the graphite ionization chambers, the maximum differences obtained were only 1.7% and 1.2% for the G1 and G2 graphite ionization chambers, respectively. Moreover, these ionization chambers presented correction factors close to 1.000, which is ideal for an ionization chamber be characterized as a reference standard system.
26

Estudo de uma câmara de ionização tipo poço através de simulação Monte Carlo / Study of a well-type ionization chamber by Monte Carlo simulation

Mairon Marques dos Santos 25 September 2009 (has links)
O uso de simulação Monte Carlo do transporte de radiação na matéria tem sido cada vez mais empregado nas áreas de física radiológica e dosimétrica. Em Medicina Nuclear é possível usar diversos códigos de simulação como ferramenta para estudar diferentes características de resposta de calibradores de dose. O código de simulação Monte Carlo PENELOPE (Penetration and ENErgy LOss of Positron and Electrons) possui um algoritmo misto do transporte de radiação, condensando eventos de interação, conforme os parâmetros de entrada estabelecidos. Neste trabalho, o código de simulação PENELOPE foi usado para estudar a resposta de uma câmara de ionização em função de diversos parâmetros que influenciam suas características de resposta. Neste trabalho os parâmetros de resposta de uma câmara de ionização tipo poço foram estudados através de simulação Monte Carlo, comparando-se os resultados obtidos com dados experimentais. A eficiência da câmara foi testada através de simulação e mostrou-se condizente com os valores previstos através de cálculos. Com relação à atividade, a resposta se mostrou linear para todos os nuclídeos estudados, sendo possível se obter a sensibilidade relativa da câmara através de simulação e de medidas experimentais. A resposta da câmara em função a energia, obtida através de simulação, também representou bem os valores experimentais, sendo possível extendê-los para energias mais altas e mais baixas que os valores das medidas experimentais. Estudos do volume de radiofármaco e da posição da fonte no poço da câmara obtidos através de simulação apresentaram comportamento esperado de acordo com a literatura. O código PENELOPE foi validado para o estudo desta câmara de ionização, permitindo que parâmetros geométricos e de materiais sejam estudados sem os custos e as dificudades dos arranjos experimentais. / The use of Monte Carlo simulation to the radiation transport in matter has been widly applied in the radiological and dosimetric areas. In Nuclear Medicine it is possible to use a variety of simulation codes as tools to study different response characteristics of dose calibrators used to measure radionuclides activities. The PENELOPE (Penetration and ENErgy LOss of Positron and Electrons) Monte Carlo simulation code has a mixed algorithm for the transport of radiation, which condenses the interaction events according to the input parameters. In this work, the PENELOPE code of simulation was used to study the response of an ionization chamber as function of parameters influencing its response. The chamber efficiency was tested by simulation and it showed a good agreement with calculated results. To the activity, its response showed a linear behavior for all studied nuclides, allowing one to obtain its sensitivity by simulation and measurements. The response of the chamber as a function of the energy obtained by simulation also showed a good agreement with the measurements, allowing one to extrapolate it to energies below and above the measured ones. The analysis with the volume of radiopharmaceuticals and position of the sourse in the chamber well obtained by simulation showed the expected behavior compared to the ones in literature. PENELOPE was validated to study this ionization chamber, so allow one to perform geometric and material parameters studies without experimental costs and difficulties.
27

Neutron spectroscopy of an accelerator based ⁷Li(p,n) neutron source with a ³He ionization chamber

Matysiak, Witold 07 1900 (has links)
Significant discrepancies had been identified by many research groups world wide between calculated and measured neutron doses from the ⁷Li(p,n) accelerator based neutron source, and therefore precise characterization of the source was needed. In this work neutron spectra from the ⁷Li(p,n) source were measured with a ³He ion chamber in the incident proton energy range from 1.95 to 2.3 MeV. The ³He detector is hypersensitive to slow neutrons, so a time-of-flight based slow neutron rejection acquisition system was built and tested. The system is based on an electrostatic proton chopper and an acquisition system working on coincidence mode. The response function of the ³He was extended down to 30 keV neutron energy and the collected neutron spectra were unfolded using two methods: van Cittert iterative algorithm with Jansson constraint, and a regularized constrained inversion. Theoretical neutron spectra emitted by the ⁷Li(p,n) source were calculated and compared with experimental unfolded spectra, as well as with results of the Monte Carlo simulations of the lithium target assembly and the walls of the experimental area. Using fluence to kerma conversion coefficients, the neutron dose was calculated and compared with results obtained from an independent experiment using the microdosimetric technique with a tissue equivalent proportional counter. Total neutron yield of the ⁷Li(p,n) reaction was measured using induced activity of ⁷Be. Results showed a negative energy offset of the incident proton beam between 50 and 58 keV with respect to the generating voltmeter indication of the accelerator terminal. Shapes of the measured neutron spectra showed significant moderation originating from neutron scattering on the lithium target assembly and walls of the experimental area. When accounting for this offset, neutron yields showed an agreement with calculated values within 22% for 1.95 MeV and within approximately 7% for higher proton energies. / Thesis / Doctor of Philosophy (PhD)
28

A quantitative method for reproducible ionization chamber alignment to a water surface for external beam radiation therapy depth dose measurements

Ververs, James 30 August 2011 (has links)
Ionization chambers (ICs) are the most commonly used detectors for radiation therapy dose measurements. Typical IC measurements use cylindrical ICs in a water phantom and therefore require initial IC alignment to the water surface. This alignment has long been ignored and only recently has a qualitative governing recommendation been made. This thesis describes a reproducible methodology for quantitative ionization chamber water surface alignment. Depth-ionization measurements are taken with twenty-eight IC designs under varying conditions including, but not limited to, changes in scan direction, speed, and resolution, radiation beam type, field size, energy, and electron contamination. Measurements are acquired using standard radiotherapy accelerators in the Virginia Commonwealth University Department of Radiation Oncology and at the National Research Council of Canada, where a customized scanning system capable of better than 0.15 mm IC positioning precision is used. Measurements are also performed with standard commercial scanning equipment on the Accuray CyberKnife, a specialized radiosurgery-class accelerator. An analytical model is developed from basic principles to test the theoretical foundations of IC response near a water surface. The theoretical foundation is further validated via Monte Carlo simulation models that fully account for all details of the ICs used to take measurements. It is determined that the dose gradient as a function of depth is maximized when a given IC reaches the water surface when moving from depth in water. This effect is unchanged under all of the measurement scenarios tested. Measurements taken at 0.1 mm resolution for several seconds per point over several millimeters near the surface will yield a gradient peak that can be used for quantitative alignment. Using developed software, multiple scans at variant resolutions can be stitched into typical clinical scans so as not to significantly affect clinical measurement workflow. The recommended measurement method is developed in a format suitable for inclusion into a clinical protocol for depth-ionization measurement acquisition.
29

Desenvolvimento de fontes radioativas seladas imobilizadas em resina epóxi para verificação de detectores utilizados em Medicina Nuclear / Development of sealed radioactive sources immobilized in Epoxy resin for verification of detectors used in nuclear medicine

Tiezzi, Rodrigo 04 February 2016 (has links)
As fontes radioativas seladas são usadas na verificação de detectores de câmara de ionização, os quais medem a atividade dos radioisótopos usados nas mais diversas áreas, como na Medicina Nuclear. A medida da atividade dos radioisótopos deve ser feita com exatidão, pois será administrada em um paciente. Para garantir o adequado funcionamento dos detectores de câmara de ionização, são estipulados ensaios normatizados pela Agência Internacional de Energia Atômica (IAEA) e a Comissão Nacional de Energia Nuclear (CNEN) utilizando-se fontes radioativas seladas de Bário-133, Césio-137 e Cobalto-57. Os testes avaliam a exatidão, precisão, reprodutibilidade e linearidade da resposta do equipamento. O foco deste trabalho foi o estudo e o desenvolvimento dessas fontes radioativas padrão de Bário-133, Césio-137 e Cobalto-57, utilizando um polímero, no caso resina epóxi comerciais do tipo éter diglicidílico do bisfenol A e um agente de cura a base de poliamina modificada da dietilenotriamina ,para imobilizar o material radioativo. A matriz polimérica apresenta a função primordial de fixar e imobilizar o conteúdo radioativo não permitindo seu vazamento dentro dos limites técnicos exigidos pelas normas de proteção radiológica no quesito de características de uma fonte selada e, adicionalmente, ter a capacidade de reter a emanação de quaisquer gases que venham a se formar durante o processo de fabricação e do período de vida útil deste artefato. O processo de manufatura de uma fonte selada padrão consiste no envasamento, em um frasco de geometria padronizada, de uma quantidade, em volume fixo, de uma matriz polimérica no interior da qual é adicionada e dispersada homogeneamente uma quantidade precisa e exata em atividade de um material radioativo padrão. Nesse sentido, realizou-se um estudo para a escolha da resina epóxi, analisando suas características e propriedades. Foram realizados estudos e testes, verificando a máxima miscibilidade da resina com a água (solução ácida, simulando as condições da solução radiativa), perdas de propriedades mecânicas e térmicas, bem como o controle de dose radioativa para a completa cura (irradiadores de cobalto).Foram produzidas fontes de césio-137 e bário-133, realizou-se testes para determinação do grau de homogeneidade na dispersão do material radioativo na matriz e testes de imersão das fontes seladas produzidas para verificar a estanqueidade do sistema desenvolvido, obtendo um resultado satisfatório de acordo com as normas. Analisando todos os resultados obtidos, as fontes seladas podem ser confeccionadas em matriz epóxi DGEBA e endurecedor poliamínico DETA modificado, desde que a quantidade de material radioativo, na forma de solução ácida, adicionado à composição não ultrapasse um teor de 20%. A cura da resina epóxi pode ser melhorada em relação a ambiente, com uso da irradiação desde que seja exposta a uma dose ao redor de 33 kGy durante a cura. Nos testes de estanqueidade, verificou-se que as fontes são estanques, as medições da atividade da água utilizada nos testes mostraram um valor inferior a 185 Bq (de acordo com a International Standard Organization- Radiation protection sealed radioactive sources - ISO 9978), comprovando a eficiência da resina epóxi como material para selar o material radioativo. Tendo a finalidade de criar uma tecnologia nacional capaz de suprir a demanda deste produto no mercado interno e atingir excelência em qualidade através da acreditação e certificação do produto junto aos órgãos competentes. / The radioactive sealed sources are used in verification ionization chamber detectors, which measure the activity of radioisotopes used in several areas, such as in nuclear medicine. The measurement of the activity of radioisotopes must be made with accuracy, because it is administered to a patient. To ensure the proper functioning of the ionization chamber detectors, standardized tests are set by the International Atomic Energy Agency (IAEA) and the National Nuclear Energy Commission using sealed radioactive sources of Barium-133, Cesium-137 and Cobalt-57. The tests assess the accuracy, precision, reproducibility and linearity of response of the equipment. The focus of this work was the study and the development of these radioactive sources with standard Barium-133 and Cesium-137, using a polymer, in case commercial epoxy resin of diglycidyl ether of bisphenol A (DGEBA) and a curing agent based on modified polyamine diethylenetriamine (DETA), to immobilize the radioactive material. The polymeric matrix has the main function of fix and immobilize the radioactive contents not allowing them to leak within the technical limits required by the standards of radiological protection in the category of characteristics of a sealed source and additionally have the ability to retain the emanation of any gases that may be formed during the manufacture process and the useful life of this artifact. The manufacturing process of a sealed source standard consists of the potting ,into bottle standardized geometry, in fixed volume of a quantity of a polymeric matrix within which is added and dispersed homogeneously to need and exact amount in activity of the radioactive materials standards. Accordingly, a study was conducted for the choice of epoxy resin, analyzing its characteristics and properties. Studies and tests were performed, examining the maximum miscibility of the resin with the water (acidic solution, simulating the conditions of radioactive solution), loss of mechanical and thermal properties, as well as the radioactive dose control for complete curing (cobalt irradiators). For this work was produced a sources of barium-133 and cesium -137,tests were conducted to determination the degree of homogeneity in the dispersion of the radioactive material in the matrix and immersion tests of sealed sources produced to verify the leakage (ISO 9978) of the developed system, occurring obtaining a satisfactory result. With the purpose of creating a national technology able to meet the demand of this product in the domestic market and achieve excellence in quality through accreditation and certification of the product by the appropriate bodies.
30

IFMIF-LIPAc Beam Diagnostics. Profiling and Loss Monitoring Systems / Les Diagnostics faisceau de IFMIF / LIPAc. Les moniteurs de profils et de pertes du faisceau

Egberts, Jan 25 September 2012 (has links)
IFMIF sera constitué de deux accélérateurs de deutons délivrant des faisceaux continus de 125mA et d’énergie 40MeV qui bombarderont une cible de lithium liquide. Face à cette très haute puissance faisceau de 10 MW, de nouveaux défis doivent être relevés pour le développement de tels accélérateurs. C’est pour cette raison qu’a été prise la décision de construire un accélérateur prototype, LIPAc (Linear IFMIF Prototype Accelerator) ayant les mêmes caractéristiques faisceau qu’IFMIF, mais avec une énergie limitée à 9MeV. Dans le cadre de cette thèse, des instruments de diagnostics faisceau ont été développés pour IFMIF et LIPAc. Ces diagnostics concernent des moniteurs de pertes faisceau ainsi que des profileurs transverse de faisceau travaillant en mode intercepteur ou non.Pour la surveillance des pertes faisceau, des chambres à ionisation et des détecteurs au diamant ont été testés et calibrés en neutrons et en γ dans la gamme en énergie de LIPAc. Lors de ces expériences, pour la première fois des diamants ont été testés avec succès à des températures cryogéniques. Pour les profileurs interceptant le faisceau, des simulations thermiques ont été réalisées afin d’assurer leur bon fonctionnement. Pour les profileurs n’interceptant pas le faisceau, des moniteurs basés sur l’ionisation du gaz résiduel (IPM) contenu dans le tube faisceau ont été développés. Un prototype a été construit et testé, puis s’inspirant de ce retour d’expérience les IPMs finals ont été conçus et construits. Pour contrecarrer la charge d’espace générée par le faisceau, un algorithme a été élaboré afin de reconstruire le profil réel du faisceau. / The IFMIF accelerator will accelerate two 125mA continuous wave (cw) deuteron beams up to 40MeV and blasts them onto a liquid lithium target to release neutrons. The very high beam power of 10MW pose unprecedented challenges for the accelerator development. Therefore, it was decided to build a prototype accelerator, the Linear IFMIF Prototype Accelerator (LIPAc), which has the very same beam characteristic, but is limited to 9 MeV only. In the frame of this thesis, diagnostics devices for IFMIF and LIPAc have been developed. The diagnostics devices consist of beam loss monitors and interceptive as well as non-interceptive profile monitors. For the beam loss monitoring system, ionization chambers and diamond detectors have been tested and calibrated for neutron and γ radiation in the energy range expected at LIPAc. During these tests, for the first time, diamond detectors were successfully operated at cryogenic temperatures. For the interceptive profilers, thermal simulations were performed to ensure safe operation. For the non-interceptive profiler, Ionization Profile Monitors (IPMs) were developed. A prototype has been built and tested, and based on the findings, the final IPMs were designed and built. To overcome the space charge of accelerator beam, a software algorithm was written to reconstruct the actual beam profile.