• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 20
  • 2
  • 1
  • Tagged with
  • 143
  • 143
  • 92
  • 58
  • 55
  • 44
  • 43
  • 36
  • 33
  • 29
  • 25
  • 25
  • 24
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Calibracao de um sistema de camara de ionizacao de poco 4'pi'-'gamma' para medidas de atividade de radio-nuclideos

DIAS, M.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:41Z (GMT). No. of bitstreams: 1 00830.pdf: 1838856 bytes, checksum: 0f6a3f75b210d4e73e342ebf7544cc17 (MD5) / Dissertacao (Mestrado) / IEA/D / Escola Politecnica, Universidade de Sao Paulo - POLI/USP
42

Medidas e analises de ruido neutronico do reator de pesquisa, tipo piscina, do Instituto de Pesquisas Energeticas e Nucleares de Sao Paulo

SIMOES, GRACIETE P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:31:28Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:28Z (GMT). No. of bitstreams: 1 01062.pdf: 7947815 bytes, checksum: 1fba37a7a6f229b1bc3aa613ad4d76a3 (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
43

Sistema de medição câmara de ionização-eletrômetro para ensaios de proteção radiológica em equipamentos de raios X para procedimentos intervencionistas / Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipments for international procedures

BOTTARO, MARCIO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:37Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:02Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
44

Avaliacao do dispositivo eletronico de imagem portal 'portal dosimetry' no controle de qualidade de radioterapia de intensidade modulada / Evaluation of electronic imaging device portal 'portal dosimetry' in quality control in intensity modulated radiotherapy

WATANABE, ERIKA Y. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:05Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:20Z (GMT). No. of bitstreams: 0 / No presente trabalho serão apresentados testes de comissionamento e de avaliação da utilização do portal dosimetry, da Varian, no controle de qualidade dos planejamentos de radioterapia de intensidade modulada. Os testes de comissionamento foram realizados para caracterizar o portal dosimetry em termos dosimétricos e para avaliar a sua possível aplicação em radioterapia. Esses testes demonstraram que o portal dosimetry possui todas as características necessárias para ser utilizado em dosimetria na radioterapia tais como linearidade da resposta com a dose, independência com a taxa de dose, reprodutibilidade, dentre outras. A avaliação da utilização do portal dosimetry no controle de qualidade de IMRT foi realizada em duas etapas: avaliação da capacidade do dispositivo em detectar erros propositalmente introduzidos em fluências simples e em fluências complexas. Foram introduzidos erros de magnitude conhecida em áreas determinadas das fluências e foi realizado o controle de qualidade dessas fluências com o portal dosimetry e com mais três sistemas dosimétricos: câmara de ionização, filme e matriz de câmaras de ionização. Os dados obtidos com o portal foram comparados com os dos outros dispositivos e todos foram capazes de identificar os erros introduzidos de maneira satisfatória, sendo os valores, normalizados para a fluência original, obtidos com o dosímetro portal indênticos aos da câmara de ionização e aos da matriz de câmaras de ionização (seven29) e diferindo em até 2% dos valores obtidos com os filmes. As fluências medidas com o portal dosimetry foram avaliadas em termos quantitativos e qualitativos. Os índices da função gama fornecidos pelo software de análise do portal dosimetry não apresentaram regras definidas de comportamento em relação aos erros introduzidos e por essa razão a análise qualitativa se mostrou indispensável nos casos avaliados. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
45

Projeto, construcao e caracterizacao de camaras de ionizacao especiais para monitoracao de feixes de radiacao X / Design, construction and characterization of special ionization chambers for X radiation beams monitoring

YOSHIZUMI, MAIRA T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:45Z (GMT). No. of bitstreams: 0 / Os equipamentos de radiação X, por estarem ligados à rede elétrica, podem apresentar flutuações na intensidade de seus feixes de radiação. Essas variações na intensidade, podem, por sua vez, modificar a taxa de kerma no ar produzida por este feixe de radiação. Em um laboratório de calibração de instrumentos, onde são realizadas calibrações de diversos equipamentos detectores de radiação, utilizados principalmente em clínicas ou hospitais, essa possível variação na intensidade do feixe de radiação pode causar um erro na determinação da dose absorvida. As câmaras de ionização monitoras são utilizadas para verificar a constância da intensidade de feixes de radiação, e fornecer uma correção para possíveis oscilações. Neste trabalho foram projetadas, construídas e caracterizadas câmaras de ionização monitoras para feixes de radiação X. As câmaras de ionização desenvolvidas possuem formato inovador, anelar, com eletrodos de alumínio ou de grafite. Essas câmaras de ionização anelares apresentam a vantagem de não interferirem no feixe direto de radiação. Foi ainda construída uma câmara de ionização com volume duplo e eletrodos de grafite, similar à câmara de ionização monitora comercial utilizada no Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares. Essas câmaras de ionização foram testadas em diversos feixes de radiação padronizados e seus desempenhos foram comparados aos de câmaras de ionização comerciais. Os resultados obtidos mostram que duas dentre as quatro câmaras de ionização desenvolvidas apresentaram desempenho comparável ao das câmaras de ionização comerciais testadas. Além de apresentarem bons resultados, as câmaras de ionização desenvolvidas foram feitas artesanalmente e utilizando materiais de baixo custo, que são facilmente encontrados no mercado. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
46

Avaliação das ferramentas de controle de qualidade para pacientes submetidos ao IMRT / Evaluation tools of quality control for patients submitted to IMRT

LAVOR, MILTON 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:22Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:31Z (GMT). No. of bitstreams: 0 / Atualmente a radioterapia de intensidade modulada (IMRT) está sendo implementada em um número crescente de centros no Brasil. Como conseqüência disto, muitas instituições estão enfrentando o problema de executar um programa de controle de qualidade antes e durante a execução do IMRT na prática da rotina clínica. O objetivo deste trabalho é avaliar e propor uma metodologia para o controle de qualidade de tratamentos com IMRT. Uma câmara de ionização e um detector bidimensional foram utilizados para avaliar a dose absoluta total de todos os campos em um determinado ponto. A distribuição de dose relativa total de todos os campos foi medida com filmes radiocrômicos e um detector bidimensional em uma profundidade no objeto simulador. Uma comparação entre as distribuições de dose medidas e calculadas foi realizada usando o método do índice gama, avaliando o percentual de pontos que satisfazem os critérios de diferença dose de ±3% e distância de concordância de ±3 mm. Como resultado da dosimetria absoluta de 113 feixes de IMRT medidos com uma câmara de ionização e 81 feixes usando o detector bidimensional, foi proposto um nível de ação de cerca de ± 5% em relação ao sistema de planejamento e de tratamento para a verificação da dose em um único ponto na região de baixo gradiente de dose. A análise das medições com o detector bidimensional mostrou que o valor da função gama foi <1 para 97,7% dos dados e, para o filme, o valor da função gama foi <1 para 96,6% dos dados. Neste trabalho pode-se concluir que para uma entrega exata de dose em IMRT sliding-window com um colimador micro multilâminas, os parâmetros de dose total absoluta e distribuição de dose total relativa devem ser verificados por dosimetria absoluta e relativa respectivamente. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
47

Caracterizacao de sistemas tandem de camaras de ionizacao comerciais para dosimetria de feixes de raio X (nivel radioterapia)

GALHARDO, EDVALDO P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:03Z (GMT). No. of bitstreams: 1 06118.pdf: 5177469 bytes, checksum: 1a0ed58fc3fd28df339dcde05cba57d4 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
48

Caracterização de uma câmara de ionização ar-livre em feixes diretos de raios X utilizados em mamografia / Characterization of a free-air ionization chamber in direct X-ray beams as used in mammography

LIMA, MATEUS H. de 21 January 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-01-21T09:58:13Z No. of bitstreams: 0 / Made available in DSpace on 2015-01-21T09:58:13Z (GMT). No. of bitstreams: 0 / Neste trabalho foram realizados testes de estabilidade e de caracterização de uma câmara de ionização de ar-livre com cilindros concêntricos da marca Victoreen, modelo 481. Os testes foram feitos utilizando feixes diretos de mamografia como uma contribuição para a implantação desta câmara como sistema padrão primário para a grandeza kerma no ar. Os testes de caracterização realizados foram: curva de saturação, eficiência de coleção de íons, efeito de polaridade, linearidade da resposta com a taxa de kerma no ar e linearidade da resposta com a variação volumétrica. O teste de eficiência de coleção de íons possibilitou a determinação do fator de correção para recombinação iônica. A maioria dos testes realizados esteve em conformidade com os limites estabelecidos por normas internacionais. Foram obtidos os fatores de correção para atenuação de fótons no ar para as qualidades de mamografia com filtros de alumínio e molibdênio. Foram determinados também os fatores de correção para transmissão e espalhamento de fótons nas bordas do diafragma para as qualidades de mamografia com filtro de alumínio e para a qualidade padrão de mamografia com filtro de molibdênio. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
49

"Intercomparação de câmaras de ionização em feixes padrões de Raios-X, níveis radioterapia, radiodiagnóstico e radioproteção" / INTERCOMPARISON OF IONIZATION CHAMBERS IN STANDARD X-RAY BEAMS, AT RADIOTHERAPY, DIAGNOSTIC RADIOLOGY AND RADIOPROTECTION LEVELS

Ana Carolina Moreira de Bessa 05 January 2007 (has links)
Tendo em vista a importância da calibração de instrumentos medidores de radiação e do conhecimento das principais características destes instrumentos, diversos tipos de câmaras de ionização foram intercomparados em termos de seus coeficientes de calibração e dependência energética, em feixes padrões de raios X, níveis radioterapia, radiodiagnóstico e radioproteção. Foi realizada uma intercomparação de activímetros utilizados em medicina nuclear, com três radionuclídeos: 67Ga, 201Tl e 99mTc. Todos os activímetros que participaram da intercomparação apresentaram resultados dentro dos limites recomendados pela norma CNEN-NE-3.05. Para completar o conjunto de qualidades de radiação do Laboratório de Calibração de Instrumentos do IPEN, foram estabelecidos feixes de radiação-X, nível radioproteção e radioterapia de energias baixas, seguindo recomendações internacionais. Três metodologias para a obtenção de coeficientes de calibração de câmaras de ionização não seladas em feixes de radiação-X foram estudadas e comparadas. Um conjunto de câmaras de ionização Victoreen, especialmente projetado para uso em intercomparações laboratoriais, foi submetido a testes de caracterização. O desempenho destas câmaras mostrou que elas podem ser utilizadas em feixes de radiação-X nível radioproteção de maneira segura, visto que nestes feixes estas câmaras apresentaram resultados em conformidade com recomendações internacionais. No entanto, seu uso em feixes de radioterapia e de radiodiagnóstico deve ser feito com algumas considerações, pois especialmente nos testes de dependência energética e de tempo de estabilização, estas câmaras não atenderam às respectivas recomendações internacionais. Este trabalho apresenta dados sobre o desempenho de diversos modelos de câmaras de ionização em diferentes feixes de radiação-X, fornecendo uma ferramenta para a escolha do instrumento mais adequado para a realização de medições em feixes de radiação ionizante / Since the calibration of radiation measurement instruments and the knowledge of their major characteristics are very important subjects, several different types of ionization chambers were intercompared in terms of their calibration coefficients and their energy dependence, in radiotherapy, diagnostic radiology and radioprotection standard beams. An intercomparison of radionuclide calibrators for nuclear medicine was performed, using three radionuclides: 67Ga, 201Tl and 99mTc; the results obtained were all within the requirements of the national standard CNEN-NE-3.05. In order to complete the range of radiation qualities of the Calibration Laboratory of IPEN, standard radiation beam qualities, radiation protection and low energy radiation therapy levels, were established, according international recommendations. Three methodologies for the calibration of unsealed ionization chambers in X-ray beams were studied and compared. A set of Victoreen ionization chambers, specially designed for use in laboratorial intercomparisons, was submitted to characterization tests. The performance of these Victoreen ionization chambers showed that they are suitable for use in radioprotection beams, because the results obtained agree with international recommendations. However, these Victoreen ionization chambers can be used in radiotherapy and diagnostic radiology beams only with some considerations, since their performance in these beams, especially in relation to the energy dependence and stabilization time tests, did not agree with the international recommendations for dosimeters used in radiotherapy and diagnostic radiology beams. This work presents data on the performance of several types of ionization chambers in different X-ray beams, that may be useful for choosing the appropriate instrument for measurements in ionizing radiation beams.
50

Desenvolvimento de uma metodologia para calibração de câmaras de ionização de placas paralelas em feixes de raios X de energia baixa em termos de dose absorvida em água / Development of a methodology for calibration of parallel plate ionization chambers for X-ray beams of low energy in terms of absorbed dose to water

Oliveira, Camila Trindade de 10 December 2015 (has links)
O objetivo deste trabalho foi estabelecer uma metodologia de calibração em termos de dose absorvida na água para câmaras de ionização de placas paralelas a serem utilizadas em feixes de radiação X de energia baixa (10 kV a 100 kV) para fins terapêuticos. Atualmente, no Brasil nenhum laboratório de calibração está oferecendo este tipo de serviço. Para o estabelecimento desta metodologia de calibração foram utilizadas duas câmaras de ionização PTW modelos 23344. Ambas as câmaras foram caracterizadas e testadas qualitativamente segundo recomendações de normas internacionais. Os testes de caracterização realizados foram: a medição da taxa de dose mínima efetiva, a curva de saturação, a eficiência da coleção de íons, a resposta quanto ao efeito da polaridade e a linearidade da câmara com a resposta. Os testes de controle de qualidade aplicados foram: estabilidade em curto e longo prazos, fuga de corrente sem irradiação, fuga de corrente após-irradiação e tempo de estabilização. Para a implantação da metodologia, foram estabelecidas as qualidades de radiação de T-10 a T-100, seguindo as recomendações do código de prática da AIEA. Desta forma, foi possível determinar a grandeza de referência, dose absorvida na água, utilizando-se as duas câmaras de ionizações e em todas as qualidades estabelecidas. / The objective of this study was to establish a calibration methodology in terms of absorbed dose to water for parallel plate ionization chambers to be used in low energy X rays beams (10kV to 100kV) for therapy purposes. Currently, in Brazil no calibration laboratory is offering this type of service. In order to establish this calibration methodology was used two ionization chambers PTW models 23344. Both chambers were characterized and tested qualitatively according to recommendations of international standards. The characterization tests performed were: measuring the effective minimum dose rate, the saturation curve, the efficiency of ions collection, polarity effect and the linearity of the ionization chamber with the response. The quality control tests applied were: stability in the short and long term, leakage current without irradiation, leakage current after irradiation and settling time. For the implementation of the methodology, the radiation qualities the T- 10 to T-100 were established, following the recommendations of the IAEA code of practice. Thus, it was possible to determine the magnitude of reference absorbed dose in water, using the two ionization chambers in the all established qualities.

Page generated in 0.1179 seconds