• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 515
  • 108
  • 50
  • 44
  • 25
  • 11
  • 11
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 1065
  • 347
  • 330
  • 195
  • 179
  • 152
  • 143
  • 135
  • 111
  • 103
  • 97
  • 92
  • 83
  • 83
  • 80
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Quantum interference and coherent control in dissipative atomic systems

Paspalakis, Emmanuel January 1999 (has links)
No description available.
232

Correlation studies of simultaneous excitation-ionization in helium

Dogan, M. January 1999 (has links)
No description available.
233

Studies of Crystal Structure Using Multiphoton Transitions in GaAs

Golin, Sarah M 02 October 2012 (has links)
We demonstrate experimentally that the multiphoton ionization rate in gallium arsenide depends on the alignment of the laser polarization with respect to the crystal axis. We show real-time modulation of 1900nm laser ionization rate, through viewing transmission, which mimics the symmetry of the semiconductor crystal. We propose that the modulation in the ionization rate arises because the varying reduced effective carrier mass, as predicted by Keldysh theory. We show direct comparison of the experimental transmission modulation depth with that predicted by Keldysh theory. This opens up a novel method for real-time non-invasive crystallography of crystalline materials.
234

Picosecond laser filamentation in air

Schmitt-Sody, Andreas, Kurz, Heiko G, Bergé, Luc, Skupin, Stefan, Polynkin, Pavel 02 September 2016 (has links)
The propagation of intense picosecond laser pulses in air in the presence of strong nonlinear self-action effects and air ionization is investigated experimentally and numerically. The model used for numerical analysis is based on the nonlinear propagator for the optical field coupled to the rate equations for the production of various ionic species and plasma temperature. Our results show that the phenomenon of plasma-driven intensity clamping, which has been paramount in femtosecond laser filamentation, holds for picosecond pulses. Furthermore, the temporal pulse distortions in the picosecond regime are limited and the pulse fluence is also clamped. In focused propagation geometry, a unique feature of picosecond filamentation is the production of a broad, fully ionized air channel, continuous both longitudinally and transversely, which may be instrumental for many applications including laser-guided electrical breakdown of air, channeling microwave beams and air lasing.
235

The Ionization and Thermal Equilibrium of a Gas Excited by Ultraviolet Synchrotron Radiation

Williams, R. E. 10 1900 (has links)
The ionization and thermal balances are considered for a gas that is ionized by a dilute radiation field, taking into account the diffuse ionizing radiation produced by the gas. A number of models are constructed in which the electron temperature and the ionization of the elements H, He, C, N, 0, Ne, and Mg are determined for optically thin and optically thick gases ionized by ultraviolet synchrotron radiation under different conditions. Conclusions are then drawn about the general characteristics of ionization by synchrotron radiation. It is shown that, in an optically thin gas, because of the insensitive frequency- dependence of synchrotron radiation each element occupies a number of different stages of ionization at any one point in the gas. It is also shown that in an optically thick gas the heavy elements remain ionized to much greater distances from the source than hydrogen and helium, and that the gas becomes thermally unstable when H and He have become almost completely neutral. In addition, observations of the emission -line intensities of the Crab Nebula are compared with a model of this object. Considerable disagreement exists between the observed and predicted intensities, and possible reasons for the discrepancy are discussed.
236

K-shell x-ray production cross sections in carbon, oxygen, fluorine, sodium, magnesium, and aluminum by 0.5 to 8.0 mev protons, helium, and lithium ions

Yu, Yueh-Chung 08 1900 (has links)
The goal of this work reported here is to test the limits of the ECPSSR theory in the transition region of the low Z1/Z2.
237

"Intercomparação de câmaras de ionização em feixes padrões de Raios-X, níveis radioterapia, radiodiagnóstico e radioproteção" / INTERCOMPARISON OF IONIZATION CHAMBERS IN STANDARD X-RAY BEAMS, AT RADIOTHERAPY, DIAGNOSTIC RADIOLOGY AND RADIOPROTECTION LEVELS

Bessa, Ana Carolina Moreira de 05 January 2007 (has links)
Tendo em vista a importância da calibração de instrumentos medidores de radiação e do conhecimento das principais características destes instrumentos, diversos tipos de câmaras de ionização foram intercomparados em termos de seus coeficientes de calibração e dependência energética, em feixes padrões de raios X, níveis radioterapia, radiodiagnóstico e radioproteção. Foi realizada uma intercomparação de activímetros utilizados em medicina nuclear, com três radionuclídeos: 67Ga, 201Tl e 99mTc. Todos os activímetros que participaram da intercomparação apresentaram resultados dentro dos limites recomendados pela norma CNEN-NE-3.05. Para completar o conjunto de qualidades de radiação do Laboratório de Calibração de Instrumentos do IPEN, foram estabelecidos feixes de radiação-X, nível radioproteção e radioterapia de energias baixas, seguindo recomendações internacionais. Três metodologias para a obtenção de coeficientes de calibração de câmaras de ionização não seladas em feixes de radiação-X foram estudadas e comparadas. Um conjunto de câmaras de ionização Victoreen, especialmente projetado para uso em intercomparações laboratoriais, foi submetido a testes de caracterização. O desempenho destas câmaras mostrou que elas podem ser utilizadas em feixes de radiação-X nível radioproteção de maneira segura, visto que nestes feixes estas câmaras apresentaram resultados em conformidade com recomendações internacionais. No entanto, seu uso em feixes de radioterapia e de radiodiagnóstico deve ser feito com algumas considerações, pois especialmente nos testes de dependência energética e de tempo de estabilização, estas câmaras não atenderam às respectivas recomendações internacionais. Este trabalho apresenta dados sobre o desempenho de diversos modelos de câmaras de ionização em diferentes feixes de radiação-X, fornecendo uma ferramenta para a escolha do instrumento mais adequado para a realização de medições em feixes de radiação ionizante / Since the calibration of radiation measurement instruments and the knowledge of their major characteristics are very important subjects, several different types of ionization chambers were intercompared in terms of their calibration coefficients and their energy dependence, in radiotherapy, diagnostic radiology and radioprotection standard beams. An intercomparison of radionuclide calibrators for nuclear medicine was performed, using three radionuclides: 67Ga, 201Tl and 99mTc; the results obtained were all within the requirements of the national standard CNEN-NE-3.05. In order to complete the range of radiation qualities of the Calibration Laboratory of IPEN, standard radiation beam qualities, radiation protection and low energy radiation therapy levels, were established, according international recommendations. Three methodologies for the calibration of unsealed ionization chambers in X-ray beams were studied and compared. A set of Victoreen ionization chambers, specially designed for use in laboratorial intercomparisons, was submitted to characterization tests. The performance of these Victoreen ionization chambers showed that they are suitable for use in radioprotection beams, because the results obtained agree with international recommendations. However, these Victoreen ionization chambers can be used in radiotherapy and diagnostic radiology beams only with some considerations, since their performance in these beams, especially in relation to the energy dependence and stabilization time tests, did not agree with the international recommendations for dosimeters used in radiotherapy and diagnostic radiology beams. This work presents data on the performance of several types of ionization chambers in different X-ray beams, that may be useful for choosing the appropriate instrument for measurements in ionizing radiation beams.
238

Medida da secção de choque de fusão do sistema ANTPOT. 18 O + ANTPOT. 10 B e construção de uma câmara de ionização sensível a posição / Measure of the shock section of fusion system 18 O + 10 B and construction of an sensitive ionization chamber in position.

Added, Nemitala 30 June 1987 (has links)
O processo de fusão completa foi investigado para a reação ANTPOT. 18 O + ANTPOT 10 B dentro do intervalo de energia de bombardeio 29,0 Mev <E IND. LAB < 72,0 Mev, no intervalo angular 5º < IND. LAB. < 27º. Para esta finalidade foi desenvolvida e construída uma câmara de ionização sensível à posição de alta resolução. Resultados experimentais comparados com previsões de modelos e sistemáticas encontradas na literatura permitem rejeitar a limitarão pelo núcleo composto para e seção de choque de fusão em energias até aproximadamente cinco vezes a barreira coulombiana. Ajustes das intensidades relativas elementares por cálculos em base e o modelo estatístico revelam uma difusividade considerável das seções de choque parciais de fusão no espeço de momento angular. Análises sistemáticas das alturas (V IND. B) e raios da barreira de fusão (R IND. B) pare núcleos vizinhos sugerem uma grande importância da difusividade da matéria nuclear na competição entre os processos de fusão e quasi-elásticos. Cálculos dentro deste contexto foram realizados. / The 18 O + 10 B within the bombarding energy range of 29,0 Mev < E LAB < 72,0 Mev, covering the 5° angular range. For this purpose, a high resolution position sensitive ionization chamber has been developed and constructed. Experimental results compared to model predictions and experimental systematics found in the literature allows to reject compound nucleus limitation to the fusion cross section up to energies as high as five times the coulomb barrier. Statistical model fits to the residues elementary distributions reveal a quite difuse partial fusion cross section in the angular momentum space. Systematic analysis of fusion barrier height (VB) and radius for neighbouring nuclei point out the importance of the nuclear matter diffuseness in the competition between the fusion and quasi-direct process. Calculations within this framework were performed.
239

Aplicação de câmaras de ionização especiais para controle de qualidade em mamografia / Application of special ionization chambers for quality control in mammography

Honda, Cristiane Jordão de Carvalho 19 August 2015 (has links)
A mamografia é um exame realizado no mamógrafo, que utiliza raios X para obter imagens da anatomia interna da mama. Para que esta imagem seja capaz de fornecer um diagnóstico correto, é necessário que os equipamentos passem constantemente por programas de controle de qualidade para que se possa garantir que as pacientes submetidas a este exame não estejam recebendo dose além da necessária, evitando-se assim possíveis efeitos biológicos indesejados. As câmaras de ionização são detectores muito utilizados para se realizar o controle de qualidade de equipamentos que utilizam radiação, como os mamógrafos. No presente trabalho foram utilizadas quatro câmaras de ionização desenvolvidas no Laboratório de Calibração de Instrumentos do IPEN LCI/IPEN, que foram submetidas a testes de caracterização em feixes padrões de radiação X do LCI. Elas apresentaram resultados satisfatórios, dentro dos limites estabelecidos pelas normas nacionais e internacionais. Como aplicação, estas câmaras de ionização foram utilizadas para testes de controle de qualidade em quatro mamógrafos clínicos de diferentes instituições quanto à repetibilidade e linearidade da taxa de kerma no ar. Os resultados obtidos nestes testes encontram-se dentro dos limites recomendados pelas normas nacionais e internacionais. / Mammography is an examination in mammography, which uses X-rays to obtain images of the internal anatomy of the breast. To provide a correct diagnosis, it is necessary that the equipment constantly undergo quality control programs to ensure that patients submitted to this examination do not receive more than the necessary dose, thus avoiding unwanted possible biological effects. The ionization chambers are widely used detectors to perform the quality control program of equipment with radiation, as mammographers. In the present study, four different special ionization chambers, developed at the Calibration Laboratory of Instruments of IPEN - LCI / IPEN, were submitted to the characterization tests in standard X radiation beams at the LCI. The results were satisfactory, within the limits estabilished by national and international standards. As an application, the ionization chambers were used for quality control tests in four mammography clinics from different institutions, as the repeatability and linearity of the air kerma rate. The results obtained in these tests were within the limits recommended by national and international standards.
240

Aplicação de câmaras de ionização especiais para controle de qualidade em mamografia / Application of special ionization chambers for quality control in mammography

Cristiane Jordão de Carvalho Honda 19 August 2015 (has links)
A mamografia é um exame realizado no mamógrafo, que utiliza raios X para obter imagens da anatomia interna da mama. Para que esta imagem seja capaz de fornecer um diagnóstico correto, é necessário que os equipamentos passem constantemente por programas de controle de qualidade para que se possa garantir que as pacientes submetidas a este exame não estejam recebendo dose além da necessária, evitando-se assim possíveis efeitos biológicos indesejados. As câmaras de ionização são detectores muito utilizados para se realizar o controle de qualidade de equipamentos que utilizam radiação, como os mamógrafos. No presente trabalho foram utilizadas quatro câmaras de ionização desenvolvidas no Laboratório de Calibração de Instrumentos do IPEN LCI/IPEN, que foram submetidas a testes de caracterização em feixes padrões de radiação X do LCI. Elas apresentaram resultados satisfatórios, dentro dos limites estabelecidos pelas normas nacionais e internacionais. Como aplicação, estas câmaras de ionização foram utilizadas para testes de controle de qualidade em quatro mamógrafos clínicos de diferentes instituições quanto à repetibilidade e linearidade da taxa de kerma no ar. Os resultados obtidos nestes testes encontram-se dentro dos limites recomendados pelas normas nacionais e internacionais. / Mammography is an examination in mammography, which uses X-rays to obtain images of the internal anatomy of the breast. To provide a correct diagnosis, it is necessary that the equipment constantly undergo quality control programs to ensure that patients submitted to this examination do not receive more than the necessary dose, thus avoiding unwanted possible biological effects. The ionization chambers are widely used detectors to perform the quality control program of equipment with radiation, as mammographers. In the present study, four different special ionization chambers, developed at the Calibration Laboratory of Instruments of IPEN - LCI / IPEN, were submitted to the characterization tests in standard X radiation beams at the LCI. The results were satisfactory, within the limits estabilished by national and international standards. As an application, the ionization chambers were used for quality control tests in four mammography clinics from different institutions, as the repeatability and linearity of the air kerma rate. The results obtained in these tests were within the limits recommended by national and international standards.

Page generated in 0.0937 seconds