• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Mensuração do torque nos movimento de flexão e extensão do joelho submetido a uma resistência: Fabricio Duarte de Almeida. -

Almeida, Fabricio Duarte de [UNESP] January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2006Bitstream added on 2014-06-13T19:16:38Z : No. of bitstreams: 1 almeida_fd_me_guara.pdf: 1139748 bytes, checksum: 725c9f2e59c64e577a3d7de4c87f51f4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os conseqüentes avanços na medicina esportiva incluem a busca por novos métodos tecnológicos que viabilizam uma melhor e mais eficaz avaliação muscular e articular no corpo humano. Associados a isso, a grande ocorrência de lesões de membros inferiores em especial aquelas da articulação do joelho, faz com que a procura por novos métodos de avaliação seja incentivada. Um recurso valioso consiste num método auxiliar de avaliação das lesões esportivas onde o exame deverá ser realizado através da aplicação de uma resistência constante. Na prática esportiva, há por um lado a importância da proporção do equilíbrio muscular agonista/antagonista, ou seja, do equilíbrio flexor/extensor representado, respectivamente, pelos isquiotibiais/quadríceps da coxa. De outro, a comparação dos valores absolutos da função muscular dos membros inferiores, quer seja para o quadríceps, ou para os isquiotibiais. Resultados alterados podem estar relacionados às lesões esportivas ou suas seqüelas. De interesse para o atleta e para a equipe multidisciplinar é poder dispor de um método de avaliação funcional muscular objetivo e seguro, que forneça dados confiáveis e reprodutíveis. Neste contexto um estudo foi desenvolvido objetivando-se a avaliação dos valores de torque bidirecional (flexão-extensão), potência, tempo e trabalho muscular do joelho quando submetido a uma resistência constante. Para tanto um dispositivo capaz de avaliar esses parâmetros foi desenvolvido no laboratório de biomecânica do Departamento de Mecânica da Unesp de Guaratinguetá, para gerar dados que caracterizem o estado físico e o desempenho dos indivíduos avaliados. Foram utilizados no estudo 19 voluntários do sexo masculino com idade entre 20-30 anos sem histórico de lesão na articulação do joelho, que foram submetidos a exercícios de flexão e extensão com amplitude de movimentos de 90 a 180° durante 40 segundos. / The consequent advances in sports medicine include the search for new technological methods that permit a more efficient evaluation of the musculature and joints of the human body. The search for new methods of evaluation has been stimulated by the increased occurrence of injuries to inferior members and in particular knee articulation. A valuable approach consists of an auxiliary method of evaluation of sportive injuries. This examination is carried out through the application of a constant resistance. In sports practice, the agonist / antagonist muscle balance, that is, the flexor/extensor balance represented, respectively, by the hamstring muscle/quadriceps femuris, plays an important role. On the other hand, the comparison between the absolute values of the inferior members is also relevant. Changed results usually relate to sports lesions or their sequels. The development of an objective and safe method to evaluate muscular functionality will provide for reliable and reproducible results of the utmost importance to athletes and multidisciplinary teams. Therefore, a study was carried out proposing to evaluate values of bi-directional torque (flexion-extension), power, time and muscular effort of the knee when submitted to a constant resistance. To accomplish this, a device capable of evaluating these parameters was developed in the biomechanics laboratory of the Department of Mechanics at UNESP - Guaratinguetá. This device generated data that characterized the physical state and performance of the evaluated individuals. The apparatus was used in the study of 19 male volunteers, 20 - 30 years old without pathological history of joint injuries. These volunteers performed flexion and extension exercises during 40 seconds, with an amplitude of movements from 90 to 180°. From these results, a minimum performance standard was determined that characterized good performance among individuals evaluated by the system.
2

Mensuração do torque nos movimento de flexão e extensão do joelho submetido a uma resistência / Fabricio Duarte de Almeida. -

Almeida, Fabricio Duarte de. January 2006 (has links)
Orientador: Araildo Lima da Silva / Banca: Tamotsu Hirata / Banca: Luis Alberto Batista / Resumo: Os conseqüentes avanços na medicina esportiva incluem a busca por novos métodos tecnológicos que viabilizam uma melhor e mais eficaz avaliação muscular e articular no corpo humano. Associados a isso, a grande ocorrência de lesões de membros inferiores em especial aquelas da articulação do joelho, faz com que a procura por novos métodos de avaliação seja incentivada. Um recurso valioso consiste num método auxiliar de avaliação das lesões esportivas onde o exame deverá ser realizado através da aplicação de uma resistência constante. Na prática esportiva, há por um lado a importância da proporção do equilíbrio muscular agonista/antagonista, ou seja, do equilíbrio flexor/extensor representado, respectivamente, pelos isquiotibiais/quadríceps da coxa. De outro, a comparação dos valores absolutos da função muscular dos membros inferiores, quer seja para o quadríceps, ou para os isquiotibiais. Resultados alterados podem estar relacionados às lesões esportivas ou suas seqüelas. De interesse para o atleta e para a equipe multidisciplinar é poder dispor de um método de avaliação funcional muscular objetivo e seguro, que forneça dados confiáveis e reprodutíveis. Neste contexto um estudo foi desenvolvido objetivando-se a avaliação dos valores de torque bidirecional (flexão-extensão), potência, tempo e trabalho muscular do joelho quando submetido a uma resistência constante. Para tanto um dispositivo capaz de avaliar esses parâmetros foi desenvolvido no laboratório de biomecânica do Departamento de Mecânica da Unesp de Guaratinguetá, para gerar dados que caracterizem o estado físico e o desempenho dos indivíduos avaliados. Foram utilizados no estudo 19 voluntários do sexo masculino com idade entre 20-30 anos sem histórico de lesão na articulação do joelho, que foram submetidos a exercícios de flexão e extensão com amplitude de movimentos de 90 a 180° durante 40 segundos. / Abstract: The consequent advances in sports medicine include the search for new technological methods that permit a more efficient evaluation of the musculature and joints of the human body. The search for new methods of evaluation has been stimulated by the increased occurrence of injuries to inferior members and in particular knee articulation. A valuable approach consists of an auxiliary method of evaluation of sportive injuries. This examination is carried out through the application of a constant resistance. In sports practice, the agonist / antagonist muscle balance, that is, the flexor/extensor balance represented, respectively, by the hamstring muscle/quadriceps femuris, plays an important role. On the other hand, the comparison between the absolute values of the inferior members is also relevant. Changed results usually relate to sports lesions or their sequels. The development of an objective and safe method to evaluate muscular functionality will provide for reliable and reproducible results of the utmost importance to athletes and multidisciplinary teams. Therefore, a study was carried out proposing to evaluate values of bi-directional torque (flexion-extension), power, time and muscular effort of the knee when submitted to a constant resistance. To accomplish this, a device capable of evaluating these parameters was developed in the biomechanics laboratory of the Department of Mechanics at UNESP - Guaratinguetá. This device generated data that characterized the physical state and performance of the evaluated individuals. The apparatus was used in the study of 19 male volunteers, 20 - 30 years old without pathological history of joint injuries. These volunteers performed flexion and extension exercises during 40 seconds, with an amplitude of movements from 90 to 180°. From these results, a minimum performance standard was determined that characterized good performance among individuals evaluated by the system. / Mestre
3

Avaliação ultra-sonográfica da articulação do joelho em equinos da raça Quarto de Milha

Cisneros Álvarez, Luis Emiliano [UNESP] 15 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-15Bitstream added on 2014-06-13T19:30:12Z : No. of bitstreams: 1 alvarez_lec_me_botfmvz.pdf: 249428 bytes, checksum: f35a467064df28dab9bd15b0a59c7dc4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foi realizado estudo ultra-sonográfico de setenta e quatro articulações do joelho de eqüinos da raça Quarto de Milha, com o objetivo de avaliar e mensurar ligamentos, tendões e meniscos. O exame foi feito mediante abordagem sistemática, na qual foram obtidas as medidas de largura, espessura, perímetro e área dos ligamentos colaterais, patelares, meniscos e tendão de origem dos músculos extensor digital longo e fibular terceiro, bem como do recesso medial. Todos os ligamentos apresentaram ecogenicidade uniforme de grau 0. O padrão das fibras foi regular e homogêneo e as margens foram bem definidas. O menisco medial foi observado triangular, com leve concavidade da margem proximal e reto na margem distal. O menisco lateral apresentou-se triangular ou trapezóide e ambas as superfícies (proximal e distal) foram retas. A analise de variância mostrou diferenças significativas entre os valores das medias dos machos e fêmeas na origem dos ligamentos patelares medial e lateral, e tendão dos músculos extensor digital longo e fibular terceiro. Estas estruturas foram maiores em fêmeas que em machos. Na comparação entre membros esquerdos e direitos, foram achadas diferenças significativas na inserção do ligamento patelar intermédio, tendão dos músculos extensor digital longo e fibular terceiro e recesso medial. Os resultados do teste de Pearson mostraram correlação media e alta entre as variáveis de largura, espessura, perímetro e área dos ligamentos, meniscos, e tendão. Porém, não foi observada correlação entre peso com o resto das variáveis. A abordagem ultra-sonográfica sistemática permitiu visualização e mensuração dos tecidos moles do joelho avaliados neste estudo. / Seventy four stifle joints of American Quarter Horses were ultrasonographically imaged in order to evaluate and measure ligaments, tendons and menisci. Ultrasonographic examination was achieved using a systematic approach. Measures of width, thickness, perimeter and area of the femorotibial collateral and patellar ligaments, menisci, tendon of origin of the long digital extensor and peroneus tertius muscles, and medial recess were obtained. The ligaments and tendon had uniform grade-0 echogenicity. Fiber pattern was regular and homogeneous, and margins were well defined. Medial meniscus was triangular shaped, slightly concave at the proximal surface and flat at the distal surface. Lateral meniscus was triangular to trapezoidal and the proximal and distal surfaces were flat. Analysis of variance showed significant differences between mean values of males and females for the origin of the medial and lateral patellar ligaments, as well as tendon of origin of the long digital extensor and peroneus tertius muscles. These structures tended to be larger in females than in males. When comparison was made between left and right hindlimb, significant differences were found for the insertion of the intermediate patellar ligament, tendon of origin of the long digital extensor and peroneus tertius muscles and medial recess. Pearson’s correlation coefficients regarding width, thickness, perimeter and area of the ligaments, menisci, and tendon showed moderate to high correlation between variables. However, correlation between weight and other variables was not observed. Ultrasonography through systematic approach allowed imaging and measurement of the soft tissues of the stifle evaluated herein.
4

Avaliação ultra-sonográfica da articulação do joelho em equinos da raça Quarto de Milha /

Cisneros Álvarez, Luis Emiliano. January 2008 (has links)
Orientador: Luiz Carlos Vulcano / Banca: Ana Liz Garcia Alves / Banca: Stefano Carlo Filippo Hagen / Resumo: Foi realizado estudo ultra-sonográfico de setenta e quatro articulações do joelho de eqüinos da raça Quarto de Milha, com o objetivo de avaliar e mensurar ligamentos, tendões e meniscos. O exame foi feito mediante abordagem sistemática, na qual foram obtidas as medidas de largura, espessura, perímetro e área dos ligamentos colaterais, patelares, meniscos e tendão de origem dos músculos extensor digital longo e fibular terceiro, bem como do recesso medial. Todos os ligamentos apresentaram ecogenicidade uniforme de grau 0. O padrão das fibras foi regular e homogêneo e as margens foram bem definidas. O menisco medial foi observado triangular, com leve concavidade da margem proximal e reto na margem distal. O menisco lateral apresentou-se triangular ou trapezóide e ambas as superfícies (proximal e distal) foram retas. A analise de variância mostrou diferenças significativas entre os valores das medias dos machos e fêmeas na origem dos ligamentos patelares medial e lateral, e tendão dos músculos extensor digital longo e fibular terceiro. Estas estruturas foram maiores em fêmeas que em machos. Na comparação entre membros esquerdos e direitos, foram achadas diferenças significativas na inserção do ligamento patelar intermédio, tendão dos músculos extensor digital longo e fibular terceiro e recesso medial. Os resultados do teste de Pearson mostraram correlação media e alta entre as variáveis de largura, espessura, perímetro e área dos ligamentos, meniscos, e tendão. Porém, não foi observada correlação entre peso com o resto das variáveis. A abordagem ultra-sonográfica sistemática permitiu visualização e mensuração dos tecidos moles do joelho avaliados neste estudo. / Abstract: Seventy four stifle joints of American Quarter Horses were ultrasonographically imaged in order to evaluate and measure ligaments, tendons and menisci. Ultrasonographic examination was achieved using a systematic approach. Measures of width, thickness, perimeter and area of the femorotibial collateral and patellar ligaments, menisci, tendon of origin of the long digital extensor and peroneus tertius muscles, and medial recess were obtained. The ligaments and tendon had uniform grade-0 echogenicity. Fiber pattern was regular and homogeneous, and margins were well defined. Medial meniscus was triangular shaped, slightly concave at the proximal surface and flat at the distal surface. Lateral meniscus was triangular to trapezoidal and the proximal and distal surfaces were flat. Analysis of variance showed significant differences between mean values of males and females for the origin of the medial and lateral patellar ligaments, as well as tendon of origin of the long digital extensor and peroneus tertius muscles. These structures tended to be larger in females than in males. When comparison was made between left and right hindlimb, significant differences were found for the insertion of the intermediate patellar ligament, tendon of origin of the long digital extensor and peroneus tertius muscles and medial recess. Pearson's correlation coefficients regarding width, thickness, perimeter and area of the ligaments, menisci, and tendon showed moderate to high correlation between variables. However, correlation between weight and other variables was not observed. Ultrasonography through systematic approach allowed imaging and measurement of the soft tissues of the stifle evaluated herein. / Mestre

Page generated in 0.0631 seconds